Exam-style questions and explanations by OpenExamPrep.

✓ No registration✓ No credit card
350+ Questions
100% Free

Loading practice questions...

Exam Review

Key Facts: CT Electrician Exam

70%

Passing Score

CT DCP

80

Questions

3.5-hour limit

$59

Exam Fee

PSI

2020 or 2023 NEC

Code Edition

PSI bulletin

Connecticut's E-2 Unlimited license is the journeyman electrician designation. The PSI-administered open-book exam has 80 questions with a 3.5-hour time limit and requires 70% to pass. Candidates may bring either the 2020 or the 2023 National Electrical Code. The DCP oversees electrical licensing in Connecticut.

Sample CT Electrician Practice Questions

Try these sample questions to review concepts for the CT Electrician exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 350+ question experience with AI tutoring.

1According to the NEC 2020 as adopted by Connecticut, what is the definition of a 'branch circuit'?
A.The circuit conductors between the final overcurrent device and the outlet(s)
B.The circuit conductors between the service point and the main disconnect
C.The circuit conductors between the transformer and the service entrance
D.The circuit conductors between two panelboards
Explanation: Per NEC Article 100, a branch circuit is defined as the circuit conductors between the final overcurrent device protecting the circuit and the outlet(s). This is fundamental to understanding electrical system layout.
2Under Connecticut's NEC 2020 adoption, what is the definition of a 'continuous load'?
A.A load operating for 1 hour or more
B.A load where maximum current continues for 3 hours or more
C.Any load that operates continuously
D.A load exceeding 80% of circuit capacity
Explanation: Per NEC Article 100, a continuous load is one where the maximum current is expected to continue for 3 hours or more. This affects sizing of conductors and overcurrent devices.
3Per the NEC 2020 as adopted in Connecticut, what is the minimum headroom required for working spaces about electrical equipment rated 600V or less?
A.6 feet
B.6 feet 3 inches
C.6 feet 6 inches
D.7 feet
Explanation: Per NEC Section 110.26(A)(3), the minimum headroom for working spaces around electrical equipment rated 600V or less is 6 feet 6 inches (6.5 feet), or the height of the equipment, whichever is greater.
4According to the NEC 2020 adopted by Connecticut, what is the required working space width in front of electrical equipment?
A.24 inches minimum
B.30 inches or the width of the equipment, whichever is greater
C.36 inches minimum
D.48 inches minimum
Explanation: Per NEC Section 110.26(A)(2), the working space width must be at least 30 inches or the width of the equipment, whichever is greater.
5Per NEC 2020 in Connecticut, what is the minimum depth of working space for Condition 1 at 0-150V to ground?
A.2.5 feet
B.3 feet
C.3.5 feet
D.4 feet
Explanation: Per NEC Table 110.26(A)(1), Condition 1 (exposed live parts on one side only) for equipment rated 0-150V to ground requires a minimum working space depth of 3 feet.
6In Connecticut, what is the minimum trade size for EMT per the NEC?
A.1/4 inch
B.3/8 inch
C.1/2 inch
D.3/4 inch
Explanation: Per NEC Section 358.20(A), the minimum trade size for EMT is 1/2 inch (metric designator 16).
7Per the NEC 2020 adopted in Connecticut, what is the maximum height for the center of a disconnect handle?
A.5 feet 6 inches
B.6 feet
C.6 feet 7 inches
D.7 feet
Explanation: Per NEC Section 404.8(A), the center of the operating handle must not be more than 6 feet 7 inches (2.0 m) above the floor when in its highest position.
8Per NEC 2020 in Connecticut, what is the maximum flexible cord length for a garbage disposal?
A.18-36 inches
B.24-48 inches
C.12-24 inches
D.36-60 inches
Explanation: Per NEC Section 422.16(B)(1), a cord-connected garbage disposal must use a flexible cord between 18 and 36 inches in length.
9Under Connecticut's NEC adoption, what is the minimum conductor size for a 20-ampere branch circuit?
A.14 AWG copper
B.12 AWG copper
C.10 AWG copper
D.8 AWG copper
Explanation: Per NEC Section 210.3 and Table 210.3, a 20-ampere branch circuit requires a minimum of 12 AWG copper.
10Per the NEC 2020 in Connecticut, what is the minimum conductor size for a 15-ampere branch circuit?
A.18 AWG
B.16 AWG
C.14 AWG copper
D.12 AWG copper
Explanation: Per NEC Section 210.3, the minimum conductor size for a 15-ampere branch circuit is 14 AWG copper.

About the CT Electrician Exam

The Connecticut E-2 Unlimited journeyman electrician exam is administered by PSI under the Department of Consumer Protection. It is an open-book test covering 16 subject areas including electrical theory, wiring methods, grounding, load calculations, motors, photovoltaics and construction safety.

Exam sponsor: Connecticut Dept. of Consumer Protection (DCP). The requirements and fees below concern the certification or admission exam, separate from our free practice resources.

Questions

80 questions

Time Limit

3.5 hours

Passing Score

70%

Exam / Certification Fees

$59

Exam sponsor website

Reported exam pass rate: Not published by DCP or PSI. Exam sponsor website

Fees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.

Our practice resources: topics covered

We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.

8 items

Raceways and Boxes

Conduit and tubing types, supports, bends, conduit fill, box and pull box sizing

7 items

General Electrical Knowledge

Electrical theory, Ohm's and Watt's laws, NEC layout, Article 100 definitions, Article 110

7 items

Service, Feeders, and Branch Circuits

Articles 210, 215, 220 and 230 including clearances, ratings and load calculations

7 items

Conductors and Cables

Ampacity, temperature correction, bundling adjustment, NM/MC/AC/UF cable rules

6 items

Grounding and Bonding

Article 250 grounding electrode systems, bonding jumpers, equipment grounding conductors

6 items

Overcurrent Protection

Article 240 standard ratings, conductor protection, device location and tap rules

6 items

Photovoltaics

Article 690 PV voltage and current sizing, rapid shutdown, disconnects and interconnection

5 items

Special Occupancies and Equipment

Hazardous locations, health care facilities, swimming pools, appliances and HVAC

5 items

Motors

Article 430 full-load current tables, conductor sizing, overload and controller rules

5 items

Fire Detection and Alarm Systems

NEC Article 760 and NFPA 72 circuit classes, separation and cable listings

5 items

Safety Information

OSHA 29 CFR 1926 construction safety, lockout/tagout, arc flash and PPE

4 items

Electrical Power

Transformers, generators, emergency and standby systems, transfer switches

3 items

Lighting

Article 410 luminaire locations, clothes closet clearances and recessed fixtures

2 items

Low Voltage

Article 725 Class 1, Class 2 and Class 3 remote-control and signaling circuits

2 items

Illuminated Signs

Article 600 electric signs, outline lighting, branch circuits and disconnects

2 items

High Voltage

Installations over 1,000 volts, working clearances and Article 490 equipment

Preparing for the CT Electrician Exam

What You Need to Know

  • Passing score: 70%
  • Exam length: 80 questions
  • Time limit: 3.5 hours
  • Exam / certification fees: $59 Official sources

Using Our Practice Resources

  • Work through all 350 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

CT Electrician: Suggested Study Strategy

1Master NEC Article 250 (Grounding and Bonding) — heavily tested on every electrician exam
2Practice dwelling unit load calculations per NEC Article 220
3Memorize conductor ampacity from Table 310.16 at 75°C
4Study conduit fill using NEC Chapter 9 tables
5Review CT-specific amendments and DCP regulations

Frequently Asked Questions

What is the Connecticut E-2 Unlimited license?

The E-2 Unlimited is Connecticut's journeyman electrician designation. It allows you to perform electrical work under the supervision of a licensed contractor.

What NEC edition does Connecticut use?

The PSI Electrical Trades bulletin permits either the 2020 or the 2023 edition of the National Electrical Code in the testing room. The 2022 Connecticut State Building Code, which governs installations in the field, adopts the 2020 NEC with Connecticut amendments.

Who administers the Connecticut exam?

The exam is administered by PSI on behalf of the CT Dept. of Consumer Protection. The state determines examination eligibility; once approved, you contact PSI directly to pay and schedule.

What experience is required?

Connecticut requires completion of an approved apprenticeship program or 8,000 hours of documented experience under a licensed electrician.