According to the NEC 2020 as adopted by Connecticut, what is the definition of a 'branch circuit'?

A
B
C
D
to track
2026 Statistics

Key Facts: CT Electrician Exam

70%

Passing Score

CT DCP

80

Questions

4-hour limit

$75-100

Exam Fee

PSI

NEC 2020

Code Edition

CT DCP

Connecticut's E-2 Unlimited license is the journeyman electrician designation. The PSI-administered exam is based on the NEC 2020, has 80 questions with a 4-hour time limit, and requires 70% to pass. The DCP oversees electrical licensing in Connecticut.

Sample CT Electrician Practice Questions

Try these sample questions to test your CT Electrician exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1According to the NEC 2020 as adopted by Connecticut, what is the definition of a 'branch circuit'?
A.The circuit conductors between the final overcurrent device and the outlet(s)
B.The circuit conductors between the service point and the main disconnect
C.The circuit conductors between the transformer and the service entrance
D.The circuit conductors between two panelboards
Explanation: Per NEC Article 100, a branch circuit is defined as the circuit conductors between the final overcurrent device protecting the circuit and the outlet(s). This is fundamental to understanding electrical system layout.
2Under Connecticut's NEC 2020 adoption, what is the definition of a 'continuous load'?
A.A load operating for 1 hour or more
B.A load where maximum current continues for 3 hours or more
C.Any load that operates continuously
D.A load exceeding 80% of circuit capacity
Explanation: Per NEC Article 100, a continuous load is one where the maximum current is expected to continue for 3 hours or more. This affects sizing of conductors and overcurrent devices.
3Per the NEC 2020 as adopted in Connecticut, what is the minimum headroom required for working spaces about electrical equipment rated 600V or less?
A.6 feet
B.6 feet 3 inches
C.6 feet 6 inches
D.7 feet
Explanation: Per NEC Section 110.26(A)(3), the minimum headroom for working spaces around electrical equipment rated 600V or less is 6 feet 6 inches (6.5 feet), or the height of the equipment, whichever is greater.
4According to the NEC 2020 adopted by Connecticut, what is the required working space width in front of electrical equipment?
A.24 inches minimum
B.30 inches or the width of the equipment, whichever is greater
C.36 inches minimum
D.48 inches minimum
Explanation: Per NEC Section 110.26(A)(2), the working space width must be at least 30 inches or the width of the equipment, whichever is greater.
5Per NEC 2020 in Connecticut, what is the minimum depth of working space for Condition 1 at 0-150V to ground?
A.2.5 feet
B.3 feet
C.3.5 feet
D.4 feet
Explanation: Per NEC Table 110.26(A)(1), Condition 1 (exposed live parts on one side only) for equipment rated 0-150V to ground requires a minimum working space depth of 3 feet.
6In Connecticut, what is the minimum trade size for EMT per the NEC?
A.1/4 inch
B.3/8 inch
C.1/2 inch
D.3/4 inch
Explanation: Per NEC Section 358.20(A), the minimum trade size for EMT is 1/2 inch (metric designator 16).
7Per the NEC 2020 adopted in Connecticut, what is the maximum height for the center of a disconnect handle?
A.5 feet 6 inches
B.6 feet
C.6 feet 7 inches
D.7 feet
Explanation: Per NEC Section 404.8(A), the center of the operating handle must not be more than 6 feet 7 inches (2.0 m) above the floor when in its highest position.
8Per NEC 2020 in Connecticut, what is the maximum flexible cord length for a garbage disposal?
A.18-36 inches
B.24-48 inches
C.12-24 inches
D.36-60 inches
Explanation: Per NEC Section 422.16(B)(1), a cord-connected garbage disposal must use a flexible cord between 18 and 36 inches in length.
9Under Connecticut's NEC adoption, what is the minimum conductor size for a 20-ampere branch circuit?
A.14 AWG copper
B.12 AWG copper
C.10 AWG copper
D.8 AWG copper
Explanation: Per NEC Section 210.3 and Table 210.3, a 20-ampere branch circuit requires a minimum of 12 AWG copper.
10Per the NEC 2020 in Connecticut, what is the minimum conductor size for a 15-ampere branch circuit?
A.18 AWG
B.16 AWG
C.14 AWG copper
D.12 AWG copper
Explanation: Per NEC Section 210.3, the minimum conductor size for a 15-ampere branch circuit is 14 AWG copper.

About the CT Electrician Exam

The Connecticut E-2 Unlimited journeyman electrician exam is administered by PSI under the Department of Consumer Protection. It tests NEC 2020 knowledge including electrical theory, wiring methods, grounding, load calculations, and Connecticut-specific amendments.

Questions

80 scored questions

Time Limit

4 hours

Passing Score

70%

Exam Fee

$75-100 (Connecticut Dept. of Consumer Protection (DCP))

CT Electrician Exam Content Outline

25%

Wiring Methods & Materials

Raceways, cables, conduit fill, conductor ampacity, and CT amendments

20%

Grounding & Bonding

Article 250, grounding electrode systems, equipment grounding, bonding

20%

Branch Circuits & Overcurrent Protection

Conductor sizing, GFCI/AFCI, receptacle spacing, overcurrent devices

20%

Load Calculations & Services

Dwelling and commercial calculations, demand factors, service entrance, feeders

15%

Motors, Special Occupancies & NEC General

Motor circuits, transformers, hazardous locations, healthcare, pools, NEC definitions

How to Pass the CT Electrician Exam

What You Need to Know

  • Passing score: 70%
  • Exam length: 80 questions
  • Time limit: 4 hours
  • Exam fee: $75-100

Keys to Passing

  • Complete 500+ practice questions
  • Score 80%+ consistently before scheduling
  • Focus on highest-weighted sections
  • Use our AI tutor for tough concepts

CT Electrician Study Tips from Top Performers

1Master NEC Article 250 (Grounding and Bonding) — heavily tested on every electrician exam
2Practice dwelling unit load calculations per NEC Article 220
3Memorize conductor ampacity from Table 310.16 at 75°C
4Study conduit fill using NEC Chapter 9 tables
5Review CT-specific amendments and DCP regulations

Frequently Asked Questions

What is the Connecticut E-2 Unlimited license?

The E-2 Unlimited is Connecticut's journeyman electrician designation. It allows you to perform electrical work under the supervision of a licensed contractor.

What NEC edition does Connecticut use?

Connecticut currently uses the NEC 2020 edition for the E-2 Unlimited electrician exam, adopted by the Department of Consumer Protection.

Who administers the Connecticut exam?

The exam is administered by PSI on behalf of the CT Dept. of Consumer Protection. Schedule through PSI after DCP application approval.

What experience is required?

Connecticut requires completion of an approved apprenticeship program or 8,000 hours of documented experience under a licensed electrician.