Exam-style questions and explanations by OpenExamPrep.

✓ No registration✓ No credit card
471+ Questions
100% Free
Same family resources

Explore More Electrician License

Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.

Exam Review

Key Facts: AL Electrician Exam

75%

Passing Score

AECB / Prov

80

Questions

4-hour limit

$115

Exam Fee

AECB

NEC 2023

Code Edition

AECB

Alabama's journeyman electrician exam is administered by Prov for the Alabama Electrical Contractors Board (AECB). It has 80 open-book questions in 240 minutes, requires 75% to pass, and uses the NEC 2023 and the American Electrician's Handbook as references. The $115 examination fee is paid to the AECB, and applicants document 8,000 hours of electrical experience.

Sample AL Electrician Practice Questions

Try these sample questions to review concepts for the AL Electrician exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 471+ question experience with AI tutoring.

1According to the NEC as adopted by Alabama, what is the definition of a 'branch circuit'?
A.The circuit conductors between the final overcurrent device and the outlet(s)
B.The circuit conductors between the service point and the main disconnect
C.The circuit conductors between the transformer and the service entrance
D.The circuit conductors between two panelboards
Explanation: Per NEC Article 100, a branch circuit is defined as the circuit conductors between the final overcurrent device protecting the circuit and the outlet(s). This definition is fundamental to understanding how electrical systems are divided and protected.
2Under Alabama's adoption of the NEC 2023, what is the minimum size copper grounding electrode conductor required for a 200-ampere service?
A.4 AWG copper
B.6 AWG copper
C.2 AWG copper
D.1/0 AWG copper
Explanation: Per NEC Table 250.66, a 200-ampere service with copper service-entrance conductors sized at 2/0 AWG or 3/0 AWG requires a minimum 4 AWG copper grounding electrode conductor. This table correlates the size of the largest service-entrance conductor to the grounding electrode conductor size.
3Per the NEC 2023 as enforced by the Alabama Electrical Contractors Board, what is the maximum voltage allowed for a Class 2 circuit?
A.30 volts
B.42.4 volts peak
C.150 volts
D.100 volts
Explanation: Per NEC Article 725 and Chapter 9 Table 11(A), Class 2 circuits are limited to 150 volts maximum, with current limitations based on the voltage level. Class 2 power sources must be listed and comply with the power limitations specified in the tables.
4In Alabama, what is the minimum number of 20-ampere small-appliance branch circuits required for the kitchen and dining areas of a dwelling unit?
A.One
B.Two
C.Three
D.Four
Explanation: NEC Section 210.11(C)(1) requires a minimum of two 20-ampere small-appliance branch circuits to serve all wall and floor receptacle outlets in the kitchen, pantry, breakfast room, dining room, and similar areas. These circuits must serve only receptacle outlets in these areas.
5According to the NEC 2023 as adopted in Alabama, what is the ampacity of a 6 AWG copper THWN-2 conductor at 75°C column?
A.55 amperes
B.65 amperes
C.75 amperes
D.85 amperes
Explanation: Per NEC Table 310.16, a 6 AWG copper conductor with THWN-2 insulation rated at 75°C has an ampacity of 65 amperes. While THWN-2 is rated for 90°C, Section 310.15(B)(2) generally requires using the 75°C column for termination purposes unless equipment is rated and listed for higher temperatures.
6Under Alabama's NEC adoption, what is the maximum percentage of conduit fill allowed for three or more conductors in a raceway?
A.31%
B.40%
C.53%
D.60%
Explanation: Per NEC Chapter 9, Table 1, when three or more conductors are installed in a raceway, the maximum fill is 40% of the conduit's total cross-sectional area. This allows adequate space for heat dissipation and ease of pulling conductors.
7Per NEC 2023 in Alabama, what is the minimum burial depth for rigid metal conduit (RMC) containing circuit conductors under a residential driveway?
A.6 inches
B.12 inches
C.18 inches
D.24 inches
Explanation: Per NEC Table 300.5 (Column 2), rigid metal conduit under one- and two-family dwelling driveways and outdoor parking areas requires a minimum cover of 18 inches. The 6-inch cover for RMC applies only to locations not specified below in the table (general areas), not under residential driveways.
8In Alabama, according to NEC Article 430, what is the maximum rating of a branch-circuit short-circuit and ground-fault protective device for a motor with a full-load current of 40 amperes using an inverse-time circuit breaker?
A.80 amperes
B.100 amperes
C.125 amperes
D.150 amperes
Explanation: Per NEC Table 430.52, an inverse-time circuit breaker used for motor branch-circuit short-circuit and ground-fault protection is permitted at a maximum of 250% of the motor full-load current. For a 40-ampere motor: 40 × 2.50 = 100 amperes. This provides adequate protection while allowing motor starting current.
9Under the NEC 2023 adopted by the AECB, what is the general lighting load in volt-amperes per square foot for a dwelling unit?
A.2 VA per square foot
B.3 VA per square foot
C.3.5 VA per square foot
D.5 VA per square foot
Explanation: Per NEC 220.41 (2023), the minimum unit load for dwelling units is 3 volt-amperes per square foot for general lighting and general-use receptacles. (Older editions listed this value in Table 220.12; the 2023 NEC relocated the dwelling unit load to 220.41.) This value is used for load calculations to determine branch-circuit and service sizing.
10Per NEC 2023 as adopted in Alabama, what is the minimum height above finished grade for service drop conductors over a residential driveway?
A.10 feet
B.12 feet
C.15 feet
D.18 feet
Explanation: NEC Section 230.24(B)(1) requires service drop conductors to maintain a minimum clearance of 12 feet above finished grade over residential driveways and commercial areas not subject to truck traffic. This clearance ensures vehicles can pass safely underneath.

About the AL Electrician Exam

The Alabama journeyman electrician exam is administered by Prov on behalf of the AECB. Its 80 open-book questions in 4 hours cover 14 areas, led by raceways and boxes, conductors and cables, and general electrical knowledge (10 questions each), with the NEC 2023 and the American Electrician's Handbook as references.

Exam sponsor: Alabama Electrical Contractors Board (AECB). The requirements and fees below concern the certification or admission exam, separate from our free practice resources.

Questions

80 questions

Time Limit

4 hours

Passing Score

75%

Exam / Certification Fees

$115

Exam sponsor website

Reported exam pass rate: Not published. Exam sponsor website

Fees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.

Our practice resources: topics covered

We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.

3.8%

Lighting

3 of the 80 exam questions

2.5%

Low Voltage

2 of the 80 exam questions

7.5%

Motors

6 of the 80 exam questions

2.5%

Electrical Power

2 of the 80 exam questions

7.5%

Special Occupancies and Equipment

6 of the 80 exam questions

12.5%

Raceways and Boxes

10 of the 80 exam questions

12.5%

Conductors and Cables

10 of the 80 exam questions

10%

Grounding and Bonding

8 of the 80 exam questions

11.2%

Service, Feeders, and Branch Circuits

9 of the 80 exam questions

12.5%

General Electrical Knowledge

10 of the 80 exam questions

2.5%

Illuminated Signs

2 of the 80 exam questions

6.2%

Overcurrent Protection

5 of the 80 exam questions

6.2%

Safety Information

5 of the 80 exam questions

2.5%

Fire Detection and Alarm Systems

2 of the 80 exam questions

Preparing for the AL Electrician Exam

What You Need to Know

  • Passing score: 75%
  • Exam length: 80 questions
  • Time limit: 4 hours
  • Exam / certification fees: $115 Official sources

Using Our Practice Resources

  • Work through all 471 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

AL Electrician: Suggested Study Strategy

1Prioritize raceways and boxes, conductors and cables, and general electrical knowledge (10 questions each), then service, feeders and branch circuits (9) and grounding and bonding (8)
2Practice dwelling unit load calculations per NEC Article 220 until you can complete them quickly and accurately
3Memorize key ampacity values from Table 310.16 for common conductor sizes at 75°C
4Study conduit fill calculations using NEC Chapter 9 tables for common conductor and raceway combinations
5Review motor circuit requirements in Article 430 including overload and short-circuit protection sizing

Frequently Asked Questions

What NEC edition does Alabama use for the electrician exam?

Prov's candidate bulletin for the Alabama Electrical Contractors Board lists NFPA 70, National Electrical Code 2023, as an open-book reference for the journeyman exam, together with the American Electrician's Handbook, 17th edition.

Who administers the Alabama electrician exam?

Prov, Inc. administers the exam on behalf of the AECB at 19 Prov testing centers in Alabama or remotely with the Examroom.ai proctoring tool. You register and schedule through Prov's website after the AECB approves your application.

Is the Alabama electrician exam open book?

Yes. The NEC 2023 and the American Electrician's Handbook, 17th edition, are permitted. Permanent tabs and pen highlighting or underlining are allowed; repositionable tabs, sticky notes, handwritten notes and added formula sheets are not.

What experience is required to take the Alabama journeyman electrician exam?

AECB rules require at least 8,000 hours of experience installing electrical wiring, apparatus or equipment for lighting or power in commercial, industrial or residential work. Up to 2,000 of those hours may be replaced by accredited electrical education or an industry-recognized apprenticeship, at 1,000 hours per year.