Cheat sheet

PTCB Nonsterile Compounding Certificate Cheat Sheet

Quick Facts

Credential
PTCB assessment-based certificate
Exam format
70 multiple-choice questions
Exam time
80 minutes
Total appointment
90 minutes including tutorial and survey
Passing scaled score
300 on a 0–400 scale
Application fee
$89
Eligibility baseline
Active PTCB CPhT certification
Eligibility routes
Recognized training or qualifying experience
Certificate renewal
None required

Plan Before Run

Master tells you how; run record shows what happened.

MFR: reusable instructionsCR: actual run

503A vs 503B

503A

  • Patient-specific prescription basis
  • Limited anticipatory quantities allowed
  • CGMP exemption if conditions met

503B

  • FDA-registered outsourcing facility
  • Patient-specific prescription not federally required
  • CGMP applies

CGMP: current good manufacturing practice

Standards and Scope

USP <795>
Nonsterile compounding standards
USP <797>
Sterile compounding standards
USP <800>
Hazardous drug handling standards
USP <659>
Packaging and storage definitions
USP <1163>
Compounding quality assurance guidance
USP–NF monograph
Article-specific quality or preparation standard
Label-directed reconstitution
Outside <795> when label followed
Changed reconstitution directions
Within nonsterile compounding scope

MFR vs Compounding Record

Master formulation record

  • Reusable plan
  • Specified components and quantities
  • Method, packaging and expected checks

Compounding record

  • Record of actual run
  • Actual component lots and quantities
  • Assigned BUD and observed checks

MFR prescribes; compounding record traces

Oversight and Responsibilities

USP
Publishes compendial standards
FDA
Enforces federal drug law
State boards of pharmacy
Oversee state-licensed pharmacy practice
NABP
Offers compounding pharmacy accreditation
NIOSH
Identifies occupationally hazardous drugs
Designated person
Accountable for facility compounding operations
Pharmacy technician
Performs authorized tasks under supervision
Compounded preparation
Not FDA-approved

Formula and Run Records

SOP
Standard operating procedure
MFR
Master formulation record
CR
Compounding record
MFR instructions
Components, quantities, method, equipment
MFR specifications
Packaging, BUD rationale, quality checks
CR traceability
Actual quantities, lots, personnel
CR release details
Assigned BUD and QC results
CoA
Certificate of analysis for components

Four BUD Caps

Aqueous first, then nonaqueous: 14–35–90–180.

Nonpreserved aqueous: 14 days refrigeratedAqueous preserved: 35 daysNonaqueous oral liquid: 90 daysOther nonaqueous: 180 days

Solution vs Suspension

Solution

  • Drug dissolved in vehicle
  • Single liquid phase

Suspension

  • Undissolved particles in liquid
  • May settle; must redisperse

Dissolved drug ≠ dispersed particles

Default BUD Picker

  1. Nonpreserved aqueous→14 days maximum; refrigerate
  2. Preserved aqueous→35 days maximum(CRT or refrigerator)
  3. Nonaqueous oral liquid→90 days maximum(CRT or refrigerator)
  4. Other nonaqueous dosage form→180 days maximum(CRT or refrigerator)
  5. Applicable USP–NF compounded preparation monograph→Do not exceed monograph BUD(Meet monograph and labeling specifications)
  6. Extend using formulation-specific stability study→Require stability-indicating method(Match formulation, packaging and storage)
  7. Shorter physical or chemical stability→Shorten the BUD

Dosage Forms and Routes

Oral solution
Drug dissolved in liquid vehicle
Oral suspension
Undissolved particles dispersed in vehicle
Emulsion
One immiscible liquid dispersed in another
Cream
Semisolid emulsion
Ointment
Semisolid; not necessarily water-free
Gel
Liquid immobilized by a network
Capsule
Enclosed drug formulation
Rectal suppository
Melts, softens, or dissolves
Troche
Dissolves slowly in the mouth
Excipient
Component serving nontherapeutic formulation role

Percent Strength Basis

Second letter tells you the denominator.

w/w: final massw/v: final volumev/v: final volume

BUD vs Manufacturer Expiration

Beyond-use date

  • Assigned to compounded preparation
  • Depends on formulation and storage

Manufacturer expiration

  • Assigned to manufactured product
  • Based on manufacturer stability data

Do not transfer expiration to compound

Tool and Technique Picker

  1. Solid needs finer particles→Triturate with mortar and pestle
  2. Insoluble powder makes gritty semisolid→Levigate with compatible liquid
  3. Small amount in large powder blend→Use geometric dilution
  4. Small viscous liquid volume→Use appropriately sized calibrated syringe
  5. Concave liquid meniscus→Read bottom at eye level
  6. Net mass excludes container→Tare balance before adding material
  7. Formula specifies final volume→Bring to volume after mixing(Do not add full volume)

Tools and Techniques

Balance
Measures mass; respect minimum weight
Tare
Subtracts empty container mass
Graduated cylinder
Measures liquid volume
Concave meniscus
Read bottom at eye level
Mortar and pestle
Grinds or mixes ingredients
Trituration
Grinds to reduce particle size
Levigation
Wets and grinds into paste
Spatulation
Mixes using a spatula
Geometric dilution
Add portions matching current mixture
Reusable equipment
Clean and sanitize per procedure

Strength and Units

% w/w
Grams per 100 g final preparation
% w/v
Grams per 100 mL final preparation
% v/v
mL per 100 mL final preparation
1% w/v
10 mg per mL
1 g
1,000 mg
1 mg
1,000 mcg
Density
Mass divided by volume
Batch scaling factor
Target yield ÷ formula yield
q.s. to volume
Add enough to reach final volume

Beyond-Use Limits

BUD
Beyond-use date for compounded preparation
Water activity a_w
Available water, not total moisture
Aqueous threshold
a_w ≥ 0.60
Nonaqueous threshold
a_w < 0.60
Default limits apply
No applicable monograph or formulation-specific data
Shorter stability
Assign a shorter BUD
Stability-study extension
180 days maximum under <795>
Aqueous extension past defaults
Also needs antimicrobial effectiveness testing
Nonaqueous oral liquid
90-day default cap
Other nonaqueous form
180-day default cap
CRT
Controlled room temperature

Packaging and Labels

Container compatibility
Match formulation and storage needs
Light-sensitive preparation
Use specified light-resistant packaging
Closure integrity
Check seal and leakage
Immediate container label
Identity, strength, BUD, storage
Lot or control number
Links container to run record
Suspension directions
Shake well when applicable
Physical warning
Precipitation or phase separation
Chemical stability concern
Potency loss or degradation

Residue Before Microbes

Deactivate residue, remove it, then clean the surface.

HD sequence starts with deactivationDecontamination removes drug residueSterile areas additionally need disinfection

C-PEC vs C-SEC

C-PEC: containment device

  • Primary engineering control
  • Contains hazard at worksite

C-SEC: containment room

  • Secondary engineering control
  • Houses the containment device

Device inside room, not interchangeable

Quality and Safety Picker

  1. Component fails barcode match→Stop and resolve mismatch
  2. Balance outside accuracy limits→Remove from use; report
  3. Final appearance differs from standard→Hold before release; notify pharmacist
  4. Storage temperature outside limits→Hold affected stock pending assessment
  5. Compounding with hazardous drug API→Use full USP <800> containment(Also follow USP <795>)
  6. Hazardous drug spill→Follow HD spill SOP(Use trained personnel)
  7. Consumer reports suspected defect→Document and investigate complaint(Trace using lot or control number)

Garb and Containment

HD
Hazardous drug
PPE
Personal protective equipment
Nonsterile compounding gloves
Required under USP <795>
Additional non-HD garb
Match task and facility procedure
HD compounding gloves
Two ASTM D6978-tested pairs
HD compounding garb
Gown, head/hair, double shoe covers
C-PEC
Device providing primary HD containment
C-SEC
Room housing primary containment device
Full-containment HD room
External exhaust and negative pressure
Nonsterile HD C-SEC ventilation
At least 12 air changes hourly
Eligible HD risk assessment
May support alternative containment measures
HD APIs
Full USP <800> containment applies

Quality Assurance vs Quality Control

Quality assurance

  • System for reliable processes
  • Procedures, competency and reviews

Quality control

  • Checks whether requirements are met
  • Appearance and specified tests

QA sets system; QC checks output

Cleaning and Exposure Control

Designated compounding space
No concurrent unrelated activities
Particle-generating activity
Assess need for closed-system processing
Hand hygiene
Wash and dry before gloves
Single-use supplies
Discard after intended use
Deactivation
Renders hazardous drug inactive
Decontamination
Removes hazardous drug residue
Cleaning
Removes organic or inorganic material
Sanitizing
Reduces microbes on inanimate surfaces
HD wipe sampling
Recommended surface residue assessment

Monitoring and Release

Temperature log
Check limits for stored materials
Humidity monitor
Tracks relative humidity
Differential pressure monitor
Checks room pressure relationship
Calibration
Compares readings with reference standards
Barcode check
Matches scanned component to selection
Electronic weight capture
Reduces manual transcription risk
Release inspection
Check appearance, label and record
Specified quality tests
Use formulation-specific acceptance criteria
Complaint investigation
Document concern and assessment
Recall traceability
Identify affected lots and recipients

Common Traps

Scale, Not Percent

300 passing scaled score ≠ 75% raw correct

Safety Is Inside Processes

72% for all Processes ≠ Separate safety and quality weight

Water Activity

Available water ≠ Total water content

Nonaqueous Caps

90 days for nonaqueous oral liquids ≠ 90 days for all nonaqueous forms

Reconstitution Scope

Following approved manufacturer directions ≠ Changing labeled reconstitution directions

Volume Denominator

100 mL final preparation ≠ 100 mL solvent added

Protect Against Carryover

Remove hazardous residue ≠ Only sanitize for microbes

Last Minute

  1. 1.Regulations 28%; Processes 72%.
  2. 2.USP <795> nonsterile; <800> hazardous handling.
  3. 3.Master formula guides; run record traces.
  4. 4.Nonpreserved aqueous: 14 days refrigerated.
  5. 5.Preserved aqueous: 35-day default cap.
  6. 6.Nonaqueous oral liquids: 90-day default cap.
  7. 7.Other nonaqueous forms: 180-day default cap.
  8. 8.Percent w/v uses final volume.
  9. 9.Match container, label and compounding record.
  10. 10.Hold failed checks before release.
Same family resources

Explore More PTCB Pharmacy Technician Certifications

Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.