Regulations, Standards, and Guidelines
28%of exam
Nonsterile Compounding Processes
72%of exam
Safety and Quality within Processes
Not publishedof exam
Quick Facts
- Credential
- PTCB assessment-based certificate
- Exam format
- 70 multiple-choice questions
- Exam time
- 80 minutes
- Total appointment
- 90 minutes including tutorial and survey
- Passing scaled score
- 300 on a 0–400 scale
- Application fee
- $89
- Eligibility baseline
- Active PTCB CPhT certification
- Eligibility routes
- Recognized training or qualifying experience
- Certificate renewal
- None required
Plan Before Run
Master tells you how; run record shows what happened.
503A vs 503B
503A
- Patient-specific prescription basis
- Limited anticipatory quantities allowed
- CGMP exemption if conditions met
503B
- FDA-registered outsourcing facility
- Patient-specific prescription not federally required
- CGMP applies
CGMP: current good manufacturing practice
Standards and Scope
- USP <795>
- Nonsterile compounding standards
- USP <797>
- Sterile compounding standards
- USP <800>
- Hazardous drug handling standards
- USP <659>
- Packaging and storage definitions
- USP <1163>
- Compounding quality assurance guidance
- USP–NF monograph
- Article-specific quality or preparation standard
- Label-directed reconstitution
- Outside <795> when label followed
- Changed reconstitution directions
- Within nonsterile compounding scope
MFR vs Compounding Record
Master formulation record
- Reusable plan
- Specified components and quantities
- Method, packaging and expected checks
Compounding record
- Record of actual run
- Actual component lots and quantities
- Assigned BUD and observed checks
MFR prescribes; compounding record traces
Oversight and Responsibilities
- USP
- Publishes compendial standards
- FDA
- Enforces federal drug law
- State boards of pharmacy
- Oversee state-licensed pharmacy practice
- NABP
- Offers compounding pharmacy accreditation
- NIOSH
- Identifies occupationally hazardous drugs
- Designated person
- Accountable for facility compounding operations
- Pharmacy technician
- Performs authorized tasks under supervision
- Compounded preparation
- Not FDA-approved
Formula and Run Records
- SOP
- Standard operating procedure
- MFR
- Master formulation record
- CR
- Compounding record
- MFR instructions
- Components, quantities, method, equipment
- MFR specifications
- Packaging, BUD rationale, quality checks
- CR traceability
- Actual quantities, lots, personnel
- CR release details
- Assigned BUD and QC results
- CoA
- Certificate of analysis for components
Four BUD Caps
Aqueous first, then nonaqueous: 14–35–90–180.
Solution vs Suspension
Solution
- Drug dissolved in vehicle
- Single liquid phase
Suspension
- Undissolved particles in liquid
- May settle; must redisperse
Dissolved drug ≠ dispersed particles
Default BUD Picker
- Nonpreserved aqueous→14 days maximum; refrigerate
- Preserved aqueous→35 days maximum(CRT or refrigerator)
- Nonaqueous oral liquid→90 days maximum(CRT or refrigerator)
- Other nonaqueous dosage form→180 days maximum(CRT or refrigerator)
- Applicable USP–NF compounded preparation monograph→Do not exceed monograph BUD(Meet monograph and labeling specifications)
- Extend using formulation-specific stability study→Require stability-indicating method(Match formulation, packaging and storage)
- Shorter physical or chemical stability→Shorten the BUD
Dosage Forms and Routes
- Oral solution
- Drug dissolved in liquid vehicle
- Oral suspension
- Undissolved particles dispersed in vehicle
- Emulsion
- One immiscible liquid dispersed in another
- Cream
- Semisolid emulsion
- Ointment
- Semisolid; not necessarily water-free
- Gel
- Liquid immobilized by a network
- Capsule
- Enclosed drug formulation
- Rectal suppository
- Melts, softens, or dissolves
- Troche
- Dissolves slowly in the mouth
- Excipient
- Component serving nontherapeutic formulation role
Percent Strength Basis
Second letter tells you the denominator.
BUD vs Manufacturer Expiration
Beyond-use date
- Assigned to compounded preparation
- Depends on formulation and storage
Manufacturer expiration
- Assigned to manufactured product
- Based on manufacturer stability data
Do not transfer expiration to compound
Tool and Technique Picker
- Solid needs finer particles→Triturate with mortar and pestle
- Insoluble powder makes gritty semisolid→Levigate with compatible liquid
- Small amount in large powder blend→Use geometric dilution
- Small viscous liquid volume→Use appropriately sized calibrated syringe
- Concave liquid meniscus→Read bottom at eye level
- Net mass excludes container→Tare balance before adding material
- Formula specifies final volume→Bring to volume after mixing(Do not add full volume)
Tools and Techniques
- Balance
- Measures mass; respect minimum weight
- Tare
- Subtracts empty container mass
- Graduated cylinder
- Measures liquid volume
- Concave meniscus
- Read bottom at eye level
- Mortar and pestle
- Grinds or mixes ingredients
- Trituration
- Grinds to reduce particle size
- Levigation
- Wets and grinds into paste
- Spatulation
- Mixes using a spatula
- Geometric dilution
- Add portions matching current mixture
- Reusable equipment
- Clean and sanitize per procedure
Strength and Units
- % w/w
- Grams per 100 g final preparation
- % w/v
- Grams per 100 mL final preparation
- % v/v
- mL per 100 mL final preparation
- 1% w/v
- 10 mg per mL
- 1 g
- 1,000 mg
- 1 mg
- 1,000 mcg
- Density
- Mass divided by volume
- Batch scaling factor
- Target yield ÷ formula yield
- q.s. to volume
- Add enough to reach final volume
Beyond-Use Limits
- BUD
- Beyond-use date for compounded preparation
- Water activity a_w
- Available water, not total moisture
- Aqueous threshold
- a_w ≥ 0.60
- Nonaqueous threshold
- a_w < 0.60
- Default limits apply
- No applicable monograph or formulation-specific data
- Shorter stability
- Assign a shorter BUD
- Stability-study extension
- 180 days maximum under <795>
- Aqueous extension past defaults
- Also needs antimicrobial effectiveness testing
- Nonaqueous oral liquid
- 90-day default cap
- Other nonaqueous form
- 180-day default cap
- CRT
- Controlled room temperature
Packaging and Labels
- Container compatibility
- Match formulation and storage needs
- Light-sensitive preparation
- Use specified light-resistant packaging
- Closure integrity
- Check seal and leakage
- Immediate container label
- Identity, strength, BUD, storage
- Lot or control number
- Links container to run record
- Suspension directions
- Shake well when applicable
- Physical warning
- Precipitation or phase separation
- Chemical stability concern
- Potency loss or degradation
Residue Before Microbes
Deactivate residue, remove it, then clean the surface.
C-PEC vs C-SEC
C-PEC: containment device
- Primary engineering control
- Contains hazard at worksite
C-SEC: containment room
- Secondary engineering control
- Houses the containment device
Device inside room, not interchangeable
Quality and Safety Picker
- Component fails barcode match→Stop and resolve mismatch
- Balance outside accuracy limits→Remove from use; report
- Final appearance differs from standard→Hold before release; notify pharmacist
- Storage temperature outside limits→Hold affected stock pending assessment
- Compounding with hazardous drug API→Use full USP <800> containment(Also follow USP <795>)
- Hazardous drug spill→Follow HD spill SOP(Use trained personnel)
- Consumer reports suspected defect→Document and investigate complaint(Trace using lot or control number)
Garb and Containment
- HD
- Hazardous drug
- PPE
- Personal protective equipment
- Nonsterile compounding gloves
- Required under USP <795>
- Additional non-HD garb
- Match task and facility procedure
- HD compounding gloves
- Two ASTM D6978-tested pairs
- HD compounding garb
- Gown, head/hair, double shoe covers
- C-PEC
- Device providing primary HD containment
- C-SEC
- Room housing primary containment device
- Full-containment HD room
- External exhaust and negative pressure
- Nonsterile HD C-SEC ventilation
- At least 12 air changes hourly
- Eligible HD risk assessment
- May support alternative containment measures
- HD APIs
- Full USP <800> containment applies
Quality Assurance vs Quality Control
Quality assurance
- System for reliable processes
- Procedures, competency and reviews
Quality control
- Checks whether requirements are met
- Appearance and specified tests
QA sets system; QC checks output
Cleaning and Exposure Control
- Designated compounding space
- No concurrent unrelated activities
- Particle-generating activity
- Assess need for closed-system processing
- Hand hygiene
- Wash and dry before gloves
- Single-use supplies
- Discard after intended use
- Deactivation
- Renders hazardous drug inactive
- Decontamination
- Removes hazardous drug residue
- Cleaning
- Removes organic or inorganic material
- Sanitizing
- Reduces microbes on inanimate surfaces
- HD wipe sampling
- Recommended surface residue assessment
Monitoring and Release
- Temperature log
- Check limits for stored materials
- Humidity monitor
- Tracks relative humidity
- Differential pressure monitor
- Checks room pressure relationship
- Calibration
- Compares readings with reference standards
- Barcode check
- Matches scanned component to selection
- Electronic weight capture
- Reduces manual transcription risk
- Release inspection
- Check appearance, label and record
- Specified quality tests
- Use formulation-specific acceptance criteria
- Complaint investigation
- Document concern and assessment
- Recall traceability
- Identify affected lots and recipients
Common Traps
Scale, Not Percent
300 passing scaled score ≠ 75% raw correct
Safety Is Inside Processes
72% for all Processes ≠ Separate safety and quality weight
Water Activity
Available water ≠ Total water content
Nonaqueous Caps
90 days for nonaqueous oral liquids ≠ 90 days for all nonaqueous forms
Reconstitution Scope
Following approved manufacturer directions ≠ Changing labeled reconstitution directions
Volume Denominator
100 mL final preparation ≠ 100 mL solvent added
Protect Against Carryover
Remove hazardous residue ≠ Only sanitize for microbes
Last Minute
- 1.Regulations 28%; Processes 72%.
- 2.USP <795> nonsterile; <800> hazardous handling.
- 3.Master formula guides; run record traces.
- 4.Nonpreserved aqueous: 14 days refrigerated.
- 5.Preserved aqueous: 35-day default cap.
- 6.Nonaqueous oral liquids: 90-day default cap.
- 7.Other nonaqueous forms: 180-day default cap.
- 8.Percent w/v uses final volume.
- 9.Match container, label and compounding record.
- 10.Hold failed checks before release.
Explore More PTCB Pharmacy Technician Certifications
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
More From This Family
Videos and articles for deeper review.