Free PTCB Nonsterile Compounding Exam Flashcards

Memorize 50 essential terms and definitions for the PTCB Nonsterile Compounding Certificate. See the term, recall the definition, then flip to check yourself.

50 Flashcards
2 Topics
100% Free
TermClick to flip

A technician reconstitutes a commercial oral powder exactly as the approved labeling directs. How does USP <795> classify that work?

Tap to reveal definition
Card 1 of 50Regulations, Standards, and Guidelines

Filter by Topic

Jump to Card

About These PTCB Nonsterile Compounding Flashcards

These 50 flashcards are designed to help you memorize key terms and definitions for the PTCB Nonsterile Compounding Certificate. Each card shows a term on the front and its definition on the back—the classic flashcard format for vocabulary memorization. Use these alongside our practice questions to build both recall and comprehension.

Topics Covered

Regulations, Standards, and Guidelines14 cards
Nonsterile Compounding Processes36 cards

Complete Flashcard Reference

Review every term in this set. Open any term to reveal its definition.

A technician reconstitutes a commercial oral powder exactly as the approved labeling directs. How does USP <795> classify that work?

Following the approved reconstitution directions is outside the chapter's nonsterile compounding requirements. Reconstitution that departs from those directions falls within the chapter's scope.

Which USP chapter applies to compounded eye drops?

USP <797> applies because ophthalmic preparations must be sterile. USP <795> covers preparations compounded as nonsterile.

When does the beyond-use clock start for a compounded nonsterile preparation?

It starts when preparation begins. The compounder's beyond-use date (BUD) is the cutoff for using the compounded preparation. A manufacturer's expiration date applies to its commercial product or component.

Where would you find the facility's routine directions for cleaning the compounding area?

In the applicable standard operating procedure (SOP). It gives staff a consistent method and identifies the work that must be documented.

What role does USP play when a state pharmacy board inspects a compounding pharmacy?

USP develops the compendial standards. The state board applies the requirements within its jurisdiction when it inspects the pharmacy.

What does PCAB nonsterile compounding accreditation evaluate?

It evaluates a pharmacy's compounding processes against accreditation standards that reference USP <795>. Its focus is the quality and consistency of the preparations.

What links compounding under section 503A to an individual patient?

The framework centers on a valid prescription for an identified patient. The law allows limited anticipatory compounding when its prescription history and established relationship conditions are met.

Who can supply compounded office stock under section 503B?

An FDA-registered outsourcing facility can fill an order for office stock if it meets the applicable 503B conditions, including current good manufacturing practice requirements.

Where should a technician check whether a newly stocked drug may need hazardous handling?

Check the facility's hazardous-drug list and flag additions for review. The facility uses the current NIOSH list, updates, and relevant manufacturer handling information to identify occupational hazards.

Which standard applies alongside USP <795> when compounding a hazardous drug?

USP <800> adds hazardous-drug handling controls that protect workers, patients, and the environment.

Who is accountable under USP <795> for how the facility and personnel perform nonsterile compounding?

The facility assigns one or more designated persons. Their responsibilities include oversight of personnel training, procedures, and the quality program.

The formula and prescription give different strengths. What should the technician do before preparing anything?

Pause and take the discrepancy to the supervising pharmacist for resolution under the facility's procedures. A guessed strength can carry the same error through the entire preparation.

Which compendial reference can give a preparation-specific BUD and packaging requirements?

A USP–NF compounded preparation monograph for that exact preparation. When using the monograph, follow its specifications and keep the BUD within the stated limit.

Which workplace reference describes a component's hazards and exposure precautions?

Its safety data sheet (SDS). Staff use it to check hazards, protective measures, and emergency information. Required sheets must be readily accessible during work shifts.

What job does a vehicle do in a compounded oral liquid?

It carries the active ingredient in dissolved or dispersed form. The vehicle can affect properties such as pH, viscosity, and stability.

A drug expected to remain dissolved forms crystals in the bottle. What kind of incompatibility does that suggest?

Precipitation is a physical incompatibility. It can reduce the amount of drug in solution and make the delivered amount unreliable.

Why can hydrolysis be a quality problem even when a preparation looks unchanged?

Hydrolysis is chemical degradation involving water. The active ingredient can lose potency without a visible change.

Which document lets you compare an API lot's test results with its quality specifications?

The certificate of analysis (CoA). Match it to the received lot and review its specifications and results before accepting the active pharmaceutical ingredient for use.

Why can a dose drawn from an undisturbed oral suspension have the wrong strength?

Undissolved particles can settle, creating uneven concentrations in the bottle. Shaking according to the labeled instructions redistributes them before measuring a dose.

In an oil-in-water emulsion, which liquid forms the dispersed droplets?

Oil forms the droplets and water is the continuous phase. Visible separation may signal that the emulsion has lost uniformity.

A formula calls for a solid dosage form that slowly releases a drug into saliva. What form fits?

A troche, also called a lozenge. It gradually dissolves or disintegrates in the mouth to release the drug.

Why verify the material of the bottle and cap before substituting a container for an oral liquid?

The preparation contacts the container and closure during storage. A different material can alter stability or protection, so check it against the formulation's packaging specifications.

What label detail helps prevent a topical liquid from being mistaken for an oral liquid?

The intended route of administration. Check it against the prescription or order and compounding record before release.

What does taring a balance with the empty weighing boat accomplish?

It accounts for the boat's mass so the balance displays the net mass of the ingredient added to it.

A balance fails its accuracy check with a reference weight. What do you do with the balance?

Take it out of use and document the failure under the facility's procedure. Resume use after the device has been corrected and verified to be within tolerance.

A clear liquid looks higher when you view its curved surface from above. How should you take the reading?

Bring your eye level with the meniscus. For a concave meniscus, read the bottom of the curve. This avoids the error caused by viewing the scale at an angle.

What is the advantage of a fresh disposable weigh boat for each powder?

A fresh contact surface reduces carryover between ingredients. Dispose of each single-use boat according to the facility's waste procedure.

What should happen to a reusable spatula before it contacts a different preparation?

Clean it and sanitize where required under the facility's equipment procedure. Residue left on the spatula can carry an ingredient into the next preparation.

What is the purpose of triturating a dry powder with a mortar and pestle?

Grinding breaks up particles or clumps and can make the powder easier to distribute evenly through the preparation.

How does geometric dilution help distribute a small amount of powder through a much larger bulk?

Blend the small amount with about an equal amount of diluent, then mix in another portion about the size of the blend so far. Repeat as the blend grows to improve distribution.

What does levigation accomplish before an insoluble powder is mixed into an ointment base?

Working the powder with a compatible liquid forms a smooth paste. That helps disperse the solid evenly and reduces grittiness.

How many grams of solute are in 150 mL of a 2% w/v practice solution?

3 g. A 2% w/v concentration contains 2 g per 100 mL of final solution, and 150 mL is 1.5 times that volume.

A practice stock contains 12 mg/mL. What stock volume contains 180 mg?

15 mL. Divide 180 mg by 12 mg/mL. The milligrams cancel and leave milliliters.

What error can a barcode mismatch catch before a component is weighed?

It can flag selection of an ingredient or strength that differs from the expected one in the system. Resolve the mismatch before using the component.

A liquid formula says 'vehicle q.s. to 60 mL.' What does the 60 mL describe?

It is the final volume of the preparation. Add enough vehicle to bring the mixture to that total volume.

What does USP <795> require staff to wear on their hands while compounding nonhazardous preparations?

Gloves are required for all compounding activities under <795>. Perform hand hygiene before donning them and follow the facility's SOP for the rest of the garb.

What hand protection is used when compounding a hazardous oral liquid?

Use two pairs of chemotherapy gloves that meet ASTM D6978. Wear the other required garb and use the required containment for the task.

What does the containment primary engineering control (C-PEC) do during nonsterile hazardous-drug compounding?

It provides ventilated containment at the work surface to limit worker and environmental exposure where the drug is handled.

How do cleaning and sanitizing serve different purposes on a nonhazardous compounding surface?

Cleaning removes materials such as powder residue. Sanitizing reduces the number of microorganisms on the surface.

What is the difference between deactivating and decontaminating a hazardous-drug work surface?

Deactivation aims to make the drug residue inactive. Decontamination removes hazardous residue from the surface. Select agents and procedures through the facility's hazardous-drug SOP.

A storage logger flags an out-of-range temperature. What should happen to affected stock first?

Hold it from use and document the excursion under the facility's SOP. Report it so the effects on the preparations and components can be assessed before they return to stock.

What pressure difference should the gauge show for a nonsterile HD compounding room relative to adjacent areas?

The room should be 0.01–0.03 inches of water column below the surrounding areas. The pressure difference directs airflow into the room and helps contain hazardous residue.

At what water activity does USP <795> classify a preparation as aqueous for default BUD selection?

At a water activity of 0.60 or higher. Water activity describes available water. Values below 0.60 fall into the nonaqueous categories.

What is the USP <795> default BUD limit for a nonpreserved aqueous preparation?

14 days in the refrigerator when there is no applicable compounded preparation monograph or preparation-specific stability information. A shorter limit may apply.

What is the USP <795> default BUD limit for a preserved aqueous preparation?

35 days at controlled room temperature or in the refrigerator when there is no applicable compounded preparation monograph or preparation-specific stability information. A shorter limit may apply.

What is the USP <795> default BUD limit for a nonaqueous oral liquid?

90 days at controlled room temperature or in the refrigerator when there is no applicable compounded preparation monograph or preparation-specific stability information. A shorter limit may apply.

What is the USP <795> default BUD limit for a nonaqueous capsule?

180 days at controlled room temperature or in the refrigerator when no applicable monograph or preparation-specific stability information exists. An earlier expiration of a commercial starting component can shorten that limit.

What should you check when visually inspecting a finished preparation for release?

Check the expected appearance and look for defects such as a leaking closure. Verify that the preparation and label agree with the compounding record and prescription or medication order.

Which record connects a finished preparation to the ingredient lots actually used?

The compounding record (CR). It documents what went into that preparation and supports tracing affected units in a recall. The master formulation record (MFR) directs how to make the formulation.

What does the designated person do when a complaint suggests a preparation has a quality defect?

Initiate a documented investigation and determine whether other preparations may be affected. Apply corrective action to all potentially affected preparations as needed.

Frequently Asked Questions

How is the PTCB Nonsterile Compounding exam structured?

PTCB gives you 80 minutes for 70 computer-based multiple-choice questions. The 90-minute appointment also includes a five-minute tutorial and a five-minute survey.

What is the passing score for the PTCB Nonsterile Compounding exam?

You need a scaled score of 300 on PTCB's 0–400 scale. PTCB reported an 83% pass rate for this exam in 2025.

What are the eligibility pathways for the certificate?

Both pathways require active PTCB CPhT certification. Complete a PTCB-recognized Nonsterile Compounding Education/Training Program or document at least 12 months of full-time pharmacy technician employment within the past eight years, with at least half of that time spent independently compounding nonsterile preparations. Submit a supervisor attestation with your application if you use the experience pathway.

Does PTCB require applicants to be at least 18?

PTCB sets no minimum age to apply for its credentials or take its exams. State pharmacy employment rules and training provider requirements can differ.

How closely do the flashcards match the exam outline?

PTCB weights Regulations, Standards, and Guidelines at 28% and Nonsterile Compounding Processes at 72%. The deck follows those weights with 14 cards on regulations and standards and 36 on compounding processes.

When can I retake the exam if I fail?

PTCB lets you reapply once you receive your official score report. Each attempt requires a new application and payment. The certificate program has no fixed waiting period or attempt limit, including after the third unsuccessful attempt.

Does the certificate require renewal?

PTCB does not require renewal of the Nonsterile Compounding Certificate.

Same family resources

Explore More PTCB Pharmacy Technician Certifications

Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.