3.8 Inventories, Schedules of Condition & Check-In Procedures
Key Takeaways
Use consistent dated check-in and check-out evidence, the agreement and reasonable cost evidence to support a deposit deduction.
Allow for pre-existing condition, ordinary wear and the item’s age at the point of loss. An apportioned replacement figure is an estimate for the evidence, not an automatic award.
For a new English tenancy in scope, check the prescribed alarms on the contractual possession date. A check-in log records what was done. Welsh alarm and electrical report duties have separate timing.
Keep statutory handover documents distinct from the inventory, key receipt, readings and any agreed review period. A compulsory inventory fee is prohibited for the English and Welsh lettings covered by their fee regimes.
When instructions end, reconcile client funds, handle the deposit under the scheme’s transfer procedure, and document the key, record and responsibility handover.
Establish condition before the tenant takes possession
An inventory lists contents and fixtures. A schedule of condition describes their state and cleanliness. The same report can do both jobs. Walk the property room by room, record existing defects and share the report with the tenant promptly. A landlord, agent or clerk can prepare it. Consistent observations, dated evidence and a fair opportunity to comment matter when the evidence is disputed. TDS inventory and check-in guide
| Item | What to record |
|---|---|
| Walls, floors and ceilings | Location and extent of scuffs, cracks, marks, stains and existing wear. |
| Fixtures, furniture and appliances | Quantity, condition, missing parts and serial or model numbers where useful. Record any checks actually made. Deal with applicable furniture fire-safety compliance separately. |
| Cleaning, outside areas and photographs | Use specific observations such as grease on the oven door. Record the supplied garden, shed or parking area where relevant. Match dated overall views and close-ups to the report. |
| Supplies and access | Record meter readings and meter identifiers, keys, fobs and remotes issued. Obtain an acknowledgement where possible. |
An agency can offer seven calendar days for comments as a practical arrangement. There is no universal statutory seven-day inventory deadline. Keep proof of delivery, comments, any revised or agreed report and relevant correspondence. A missing signature can affect the weight of the evidence. It does not by itself rule out a deduction. TDS evidence guidance · TDS guidance on claims without an inventory
Use the records in a deposit dispute
The person claiming a deduction normally has to show that the agreement was breached and support the amount sought. Compare the condition at check-in and check-out. Consider the tenant’s comments, photographs and maintenance records alongside invoices, receipts or quotations. Distinguish ordinary wear from damage, and check whether cleaning or repair could reasonably address the loss before treating replacement as necessary.
Worked example. A carpet was four years old at check-in. A year later a tenant-caused stain is shown to make replacement necessary. Comparable replacement is £450 and the evidenced useful life is eight years. The carpet had three years of useful life left at check-out. An illustrative apportioned amount is £450 × 3 ÷ 8 = £168.75, subject to the condition and cost evidence. The landlord has to justify the claim. TDS guidance on damage and missing items · DPS guidance on betterment
Hand over the correct documents and record the checks
| Timing | In-scope private letting in England | In-scope occupation contract in Wales |
|---|---|---|
| Before agreement or occupation | Give the prescribed written information before agreeing a new private assured tenancy from 1 May 2026. Before occupation give the new tenant the applicable gas safety record and electrical inspection report. Carry out the applicable Right to Rent checks. | Give the new contract-holder the applicable gas safety record before they occupy. Check that the required electrical condition report is valid when the dwelling is occupied. The electrical report delivery deadline is separate. |
| At handover | Test prescribed alarms on the day the new tenancy begins, meaning the date the tenant is entitled to possession. A dated check-in record is useful evidence. | Ensure the required mains-powered, interlinked smoke alarms and carbon monoxide alarms are working during occupation. Apply the Welsh rules, including the kinds of appliance they cover. |
| After occupation or payment | If a tenancy security deposit is received, meet the authorised scheme’s initial requirements and provide prescribed information within 30 days of receipt. | For a new contract, give the written statement, landlord address notice and copy of the valid electrical condition report by the end of the respective 14-day periods starting on the occupation date. Protect any security deposit and give required information within 30 days beginning on the day it is paid. |
In both countries, where the energy performance rules apply, make a valid EPC available free at the prescribed stage for prospective tenants and give it free to the incoming tenant. The normal gas handover rule has limited display exceptions. Keep a record of what was given, when, and to whom. Share the rent payment details and any optional standing order instructions, reporting contacts, emergency arrangements and relevant appliance instructions. Explain the location of shut-offs and alarms. Keep the signed inventory and key acknowledgement with the tenancy records where available. Written terms in England · Gas safety regulation 36 · EPC regulation 6 · English electrical regulation 3 · English alarm regulation 4 · Welsh move-in checklist · Welsh electrical regulation 6
An in-scope English agent cannot require a tenant to pay a £95 inventory fee, including by directing payment to a third-party clerk. The financial penalty can be up to £5,000 for a breach that is not a repeat offence. For a qualifying repeat offence, the authority can prosecute or impose up to £30,000 instead. An ordinary compulsory inventory fee is also prohibited under the separate Welsh regime. English Tenant Fees Act, sections 2, 8 and 12 · Welsh fees guidance
For a historical English assured shorthold tenancy scenario, the How to Rent checklist was prescribed information for section 21. The regulations prescribing it were revoked from 1 May 2026. In a saved possession case, check the requirements applicable to the old notice at the time it was given. For a new English private assured tenancy apply the prescribed written terms regime described above. 2015 prescribed requirements · 2026 revocation
Hand over to a replacement agent
- Agree the end date and authority. Confirm the handover date, fees or credits, who will hold keys, and the new agent’s authority. The outgoing agent’s final statement should identify balances still owed either way. Notify the tenant of the new agent, verified payment instructions and where to report repairs. Check if a revised statutory address notice is needed.
- Reconcile rent and deposits separately. Record the balance for each client, outstanding rent or invoices and the transfer instructions. Confirm with the deposit scheme who holds the deposit and how to update or transfer it without a gap in protection. A change of agent does not by itself end or replace the tenancy. Record confirmation of the transfer and any communication or information the scheme and applicable law require.
- Transfer what the new agent needs. Include the agreement, inventory and photographs, key schedule, safety records and expiry dates, notices, deposit evidence, rent statements and unresolved repairs, complaints or payment arrangements. Confirm receipt securely. Identify the lawful basis for personal data disclosed, limit it to what is needed, and keep or dispose of the outgoing file in line with applicable requirements.
The Property Ombudsman residential letting code for England, instructions and termination · ICO data sharing guidance · English deposit requirements · Welsh deposit requirements
An eight-year expected-life carpet is four years old at check-in. A year later a tenant-caused stain makes replacement necessary. An equivalent carpet costs £450. On the stated assumptions, what illustrative contribution reflects the remaining useful life?
£450 because the stain exceeds ordinary wear.
£0 because a carpet more than three years old has no residual value.
£168.75, subject to the condition and cost evidence.
£225 because the carpet was halfway through its life at check-in.
Under regulation 4 of the English smoke and carbon monoxide alarm regulations, when must the landlord arrange the working-order checks for prescribed alarms in a new specified tenancy?
On the day the tenant is entitled to possession under the tenancy.
Within 28 days after the tenant moves in.
At the next annual gas safety check.
Only when the local authority asks for proof that the property is an HMO.
For an in-scope English letting, an agent requires the new tenant to pay £95 directly to the agent’s chosen inventory clerk for check-in. The conduct is a first breach. How is it treated under the Tenant Fees Act 2019?
Permitted, because the fee is paid to an independent third-party clerk rather than retained by the agent
Permitted, provided the £95 charge is transparently highlighted in bold in the tenancy agreement
Permitted only if the landlord agrees to pay for the check-out report at the end of the tenancy
Unlawful as a prohibited payment, exposing the agent to civil penalties of up to £5,000 for a first breach
Sections you finish are checked off in the contents.