1.7 Gas Safety Checks and Domestic Alarms
Key Takeaways
Maintain relevant gas fittings and flues safely and arrange the required gas appliance and flue checks with an appropriately qualified Gas Safe registered engineer.
A qualifying gas safety check in the two months ending on the deadline can preserve the next annual deadline. Existing tenants normally receive the new record within 28 days of the actual check.
Retain a gas check record until two further checks of that appliance or flue. If it is removed, retain the last record for two years after the last check.
In England, a covered tenancy requires a smoke alarm on every storey with living accommodation and a carbon monoxide alarm in each room used wholly or partly as living accommodation with a fixed combustion appliance other than a gas cooker.
In Wales, covered occupation contracts require working mains-connected and interlinked smoke alarms and a working carbon monoxide alarm in each room with a relevant appliance during occupation.
Separate maintenance, checks and records
The Gas Safety (Installation and Use) Regulations 1998 apply to relevant rented premises in Great Britain, including England and Wales. Regulation 36 requires the landlord to maintain relevant gas fittings and flues safely. The annual check applies to relevant appliances and flues. The landlord normally remains responsible for relevant installation pipework serving the property even where the appliance belongs to the tenant. A landlord’s appliance check does not extend to the tenant’s own appliance. Use a Gas Safe registered engineer qualified for the work and verify the relevant categories on their identification. An annual check does not replace ongoing maintenance. Regulation 36 · Health and Safety Executive guidance for landlords and agents
Review the management contract to identify who books the check, deals with safety defects, retains the record and supplies copies. HSE explains that where the contract makes the managing agent responsible for these duties, the same duties apply to that agent. On a let-only instruction, identify who takes over after handover. When a check flags an unsafe appliance, arrange appropriate action with the engineer and prevent use while unsafe. The landlord gas safety record, sometimes called a CP12, records the results of the check, including defects found. Keep evidence of follow-up work separately. HSE on gas safety records
Work out the deadline and the delivery date
Check a relevant new appliance or flue within 12 months of installation and ordinarily at intervals of no more than 12 months thereafter. Check the relevant record before admitting a new tenant. Under regulation 36A, a qualifying inspection in the two months ending on the deadline is treated as occurring on that deadline for scheduling the next check. For example, a check on 10 October 2026 for an appliance due by 30 November 2026 falls within the two-month window. Its next deadline can remain 30 November 2027. A check on 10 August 2026 would ordinarily set a new annual date of 10 August 2027. A late check does not cure the preceding gap. 2018 Gas Safety Amendment Regulations
| Event | Record action |
|---|---|
| Check completed during the tenancy | Normally give each existing tenant a copy within 28 days of the actual date of the check. In the example, 28 days after 10 October is 7 November. |
| New tenant about to occupy | Normally give the latest record before occupation. Agree electronic delivery where the tenant can access it and provide paper if requested. |
| New tenant has a right to occupy for no more than 28 days | Regulation 36(6)(b) permits prominent display in the premises instead of individual delivery. A separate display route applies where no relevant appliance is in a room occupied by the tenant. Under the latter route, endorse the displayed record with the tenant’s right to a copy on request and the address for requesting it. Tell a new tenant where the notice is and how to obtain a copy. |
| Record stored for an appliance or flue | Retain until two further checks of that appliance or flue. If it is removed, retain the record for two years after its last check. |
If the tenant repeatedly refuses access, offer practical appointment choices, explain the safety reason and retain evidence of attempts and communications. Keep using lawful access procedures and consider seeking an access order where needed. The facts determine whether reasonable steps have been taken. A fixed number of logged attempts does not by itself settle that question, and the agent should not force entry for the routine check. HSE on access
Apply the right alarm rules
In England, the Smoke and Carbon Monoxide Alarm (England) Regulations 2015, amended from 1 October 2022, cover specified tenancies. During occupation, provide at least one smoke alarm on each storey containing a room used wholly or partly as living accommodation. Provide a carbon monoxide (CO) alarm in each room used wholly or partly as living accommodation containing a fixed combustion appliance other than a gas cooker. Halls and bathrooms are treated as living accommodation for this purpose. An English three-storey letting with living accommodation on each storey, a fixed oil boiler in a relevant hallway and only a gas cooker in the kitchen therefore needs at least three smoke alarms and one CO alarm on the stated facts.
Ensure the prescribed alarms work on the day a new tenancy begins. Keep a record of the checks. If the tenant or their representative reports a fault and an alarm is found to be faulty, repair or replace it as soon as reasonably practicable. An English local housing authority can serve a remedial notice and may impose a penalty of up to £5,000 for failure to comply with it. The normal notice period is 28 days from service, subject to the rules on representations and suspension. English alarm regulations · Enforcement guidance
In Wales, regulation 5 of the Renting Homes (Fitness for Human Habitation) (Wales) Regulations 2022 uses the occupation contract framework. During occupation, at least one working smoke alarm must be on each storey, connected to the electricity supply and linked to the other smoke alarms connected to the electricity supply where there is more than one. A working CO alarm is required in each room containing a gas appliance, an oil-fired combustion appliance or a solid-fuel burning combustion appliance. A cooking appliance can qualify under the Welsh definition of gas appliance. Check its exemptions, including portable or mobile appliances powered by a cylinder and appliances the contract-holder is entitled to remove under the contract. In Wales a hall, landing or corridor counts as a room. The dwelling is treated as unfit while the alarm requirements are unmet. Welsh fitness regulations · Welsh Government landlord guidance
The annual gas safety check deadline for a landlord’s boiler is 30 November 2026. A qualified Gas Safe registered engineer completes the check on 10 October 2026. Under regulation 36A, what deadline can be retained for the next check?
10 October 2027, because all safety certificates run strictly 12 months from the inspection date
30 November 2027, because the check fell within the 2-month MOT-style flexibility window
28 December 2027, allowing for the 28-day tenant service period
31 October 2027, rounded to the end of the month in which the check occurred
In a private rented home in England subject to the 2015 alarm regulations as amended, which space requires a carbon monoxide alarm on the stated facts?
A kitchen containing only a gas cooker and a separate electric oven.
A basement storage cellar with no living accommodation and no combustion appliances
An upper-floor bedroom heated exclusively by a wall-mounted electric panel heater
A ground-floor hallway containing a wall-mounted oil-fired central heating boiler
A tenant repeatedly cancels appointments for the annual gas safety check despite clear notice. Which course of action best protects the landlord and managing agent under the 1998 Regulations?
Offer practical alternatives, keep evidence of reasonable access attempts, and pursue lawful access if checks remain outstanding.
Use the managing agent's spare keys to enter the property without consent so the engineer can complete the check
Wait until the tenant decides to move out and deduct any penalty charges from their tenancy deposit
Ask the Local Housing Authority to prosecute the tenant for failing to maintain the boiler