5.1 Titrimetric, Gravimetric & Electrochemical Analysis

Key Takeaways

  • A primary standard has a reliably assigned content and suitable handling properties for its specific use. Potassium hydrogen phthalate is an example.

  • Solvent and endpoint choice depend on the analyte and monograph. Historical mercury treatment and current mercury-free compendial examples belong to different procedures.

  • Iodimetry uses iodine directly. Iodometry determines the iodine liberated by an oxidant, commonly with thiosulfate.

  • Mohr, Volhard and Fajans methods detect distinct changes in precipitation titrations. Exposed silver chloride can consume thiocyanate in a Volhard back-titration.

  • Polarographic half-wave potential can aid identification under stated conditions. Diffusion-controlled current can be used for quantitation.

Last updated: November 2026

Titrimetric, Gravimetric & Electrochemical Analysis

Standards, errors and endpoints

Precision describes agreement among repeated results under stated conditions. Standard deviation or relative standard deviation can summarize it. Accuracy concerns agreement with a reference or accepted value. Recovery of a known addition is one way to investigate bias. Repetition helps estimate random variability and reduces its contribution to the uncertainty of the mean. An uncalibrated balance can still bias all results.

Primary standards have a reliably assigned content and suitable stability and handling properties for the intended use. High formula or equivalent mass can reduce relative weighing error. NIST supplies potassium hydrogen phthalate (KHP) as an acidimetric primary standard. A sodium hydroxide titrant can take up water and carbon dioxide, so establish its actual concentration by standardization for the intended procedure. NIST SRM 84L certificate

The equivalence point is the stoichiometric point. The endpoint is the point signalled by the chosen method, such as a colour change or an inflection in measured potential. Choose an indicator whose transition overlaps the steep part of the titration curve. For example, phenolphthalein can be suitable for some weak-acid/strong-base titrations, while an indicator with a lower transition such as methyl orange can be suitable when the relevant equivalence region is acidic. The cited International Pharmacopoeia ibuprofen substance assay uses methanol as the sample solvent, carbonate-free sodium hydroxide as titrant, and phenolphthalein as indicator. It includes a blank correction. WHO ibuprofen monograph

Non-aqueous acid–base titration

Choice of solvent changes solubility, acid–base equilibria and the shape of the endpoint. Some bases are titrated with perchloric acid in a suitable non-aqueous medium. Some weak acids use lithium methoxide or a different specified non-aqueous base. Read the monograph for the actual solvent, titrant, blank and detection method.

In historical procedures for some hydrochloride salts of weak bases, mercury(II) acetate bound chloride, allowing an acetate-based acid–base titration. WHO documented mercury-free alternatives. Its published ephedrine hydrochloride substance monograph uses dehydrated ethanol, a known addition of dilute hydrochloric acid, and titration with sodium hydroxide. The volume between the two inflections corresponds to the ephedrine hydrochloride content. WHO historical consultation · WHO non-aqueous titration chapter · WHO ephedrine hydrochloride monograph

Worked calculation. In a classroom example for that 1:1 stoichiometry, 0.1500 g of sample consumes 7.40 mL of 0.1000 mol/L sodium hydroxide between the two inflections. Use a molar mass of 201.7 g/mol.

n=0.00740 L×0.1000 mol/L=0.000740 mol,m=n×201.7 g/mol=0.14926 g.n=0.00740\,\mathrm{L}\times0.1000\,\mathrm{mol/L}=0.000740\,\mathrm{mol}, \qquad m=n\times201.7\,\mathrm{g/mol}=0.14926\,\mathrm{g}.

The estimated content is 100(0.14926/0.1500)≈99.5%100(0.14926/0.1500)\approx99.5\%. The calculation uses the interval between inflections, so the initially added acid is already accounted for by the first endpoint. For Indian compliance, identify the applicable Indian Pharmacopoeia edition and monograph for the tested substance or product. IPC Indian Pharmacopoeia 2026 materials

Redox, precipitation and complex formation

MethodDetection principle and example
PermanganometryPermanganate can serve as its own visual indicator. In a suitable acidic method a persistent excess gives a faint pink colour.
CerimetryCe(IV) accepts an electron from an analyte such as Fe(II). The WHO ferrous sulfate substance assay uses ceric ammonium sulfate and a phenanthroline indicator.
IodimetryDirect iodine titration of a reductant such as ascorbic acid. In the WHO method starch is added near the endpoint.
IodometryAn oxidant liberates iodine from iodide. Thiosulfate titration measures the liberated iodine. Two moles of thiosulfate react per mole of iodine in the usual reaction.
Karl FischerWater participates in an iodine-based reaction. A volumetric method adds standardized reagent, while the coulometric method generates iodine in the cell. Check sample compatibility and the validated range.
MohrSilver nitrate precipitates chloride. The first persistent silver chromate colour signals excess silver under suitable pH conditions. For example, US EPA method 9253 specifies pH 8.3 for its stated matrix.
VolhardAfter excess silver precipitates chloride, determine residual silver by thiocyanate in acid with an iron(III) indicator. Separate or isolate the silver chloride as the chosen procedure specifies.
FajansAn adsorption dye senses a change in surface charge. In a silver chloride method, an anionic dye can adsorb after excess silver makes the particle surface positive.
ComplexometryEDTA binds many metal ions in a 1:1 molar ratio. Control pH to obtain suitable complexation and indicator behaviour. Metal identity, pH and interferences determine the selected indicator and masking strategy.
DiazotizationA primary aromatic amino group reacts with nitrite under acidic conditions. The WHO sulfamethoxazole monograph uses the compendial nitrite titration.

In the Volhard back-titration, exposed silver chloride can react with thiocyanate to form less soluble silver thiocyanate. The extra thiocyanate overstates residual silver and biases calculated chloride low. In a gravimetric measurement of chloride with silver chloride instead, calculate mCl=mAgClMCl/MAgClm_{\mathrm{Cl}}=m_{\mathrm{AgCl}}M_{\mathrm{Cl}}/M_{\mathrm{AgCl}} because the molar ratio is 1:1. Isolate and dry the weighed phase as specified. Coprecipitation, incomplete transfer and incorrect drying can bias the result. Original Volhard modification · EPA chloride method · WHO ferrous sulfate monograph · WHO ascorbic acid monograph · WHO complexometry chapter · WHO coulometric Karl Fischer chapter · WHO sulfamethoxazole monograph

Electrochemical methods

  • Potentiometry measures potential between an indicator and reference electrode with negligible current. For a reversible half-reaction at 25 °C, the base-10 Nernst form is E=E∘−(0.05916/n)log⁡10QE=E^\circ-(0.05916/n)\log_{10}Q in volts. Write the quotient QQ for the electrode reaction. A potential–volume curve can reveal one or more endpoints.
  • Conductometry measures conductivity or conductance as titrant changes the types and amounts of ions. Intersections of suitable fitted segments can locate endpoints. The curve shape depends on the system.
  • Polarography uses a dropping mercury electrode in the classical method. The half-wave potential can help identify a species under controlled solution conditions. For diffusion control, the Ilkovič relation makes the current magnitude proportional to nD1/2m2/3t1/6CnD^{1/2}m^{2/3}t^{1/6}C in the limiting-current approximation, with electron count nn, diffusion coefficient DD, mercury flow rate mm, drop time tt and bulk concentration CC. High supporting electrolyte suppresses analyte migration. Select the electrolyte to avoid interference, and account for dissolved oxygen and residual current when relevant. IUPAC conductometric titration · IUPAC Ilkovič equation
Test Your Knowledge

What was the analytical role of mercury(II) acetate in historical non-aqueous acidimetry of certain weak-base hydrochloride salts?

A

To oxidize the drug to a stronger base

B

To bind chloride and provide a titratable acetate system

C

To remove atmospheric carbon dioxide from acetic acid

D

To act as a primary standard for the acid

Test Your Knowledge

Why does a Volhard determination of chloride separate or isolate the silver chloride before back-titrating the residual silver with thiocyanate?

A

Chloride ions oxidize ferric alum indicator in nitric acid medium

B

AgCl dissolves rapidly in nitric acid above pH 2

C

Nitrobenzene acts as the adsorption indicator for the blood-red complex

D

AgSCN is less soluble than AgCl, so SCN- would displace Cl- from AgCl and cause a low chloride result

Test Your Knowledge

In diffusion-controlled polarography at a dropping mercury electrode, why is a compatible supporting electrolyte present in large excess?

A

To suppress migration of the analyte so diffusion can dominate its transport

B

To shift every half-wave potential in the positive direction

C

To remove dissolved oxygen in place of deoxygenation

D

To cause mercury drops to gather at the capillary tip

Sections you finish are checked off in the contents.