13.4 Pharmacovigilance (PvPI), Quality Assurance & Environmental Compliance
Key Takeaways
The Indian Pharmacopoeia Commission in Ghaziabad is the National Coordination Centre for the Pharmacovigilance Programme of India. Health professionals and patients can report suspected reactions.
The Naranjo algorithm classifies a numerical score. WHO–UMC causality categories use case characteristics such as timing, competing causes and response after withdrawal.
Revised Schedule M requires documented investigation of out-of-specification results under an approved procedure. Corrective and preventive action follows the findings.
Under the Bio-Medical Waste Management Rules, expired and discarded medicines are in the yellow stream, including items contaminated with cytotoxic drugs.
Biochemical oxygen demand and chemical oxygen demand use different test methods. India’s bulk-drug and formulation effluent standard specifies BOD after three days at 27 °C.
Reporting suspected adverse reactions
Pharmacovigilance detects, evaluates and helps prevent adverse effects and other medicine-related problems. With the Pharmacovigilance Programme of India (PvPI), healthcare professionals and patients can submit a suspected adverse drug reaction (ADR) report. A pharmacist can report a new symptom after a medication change even if another medicine or an underlying illness could also explain it.
The Indian Pharmacopoeia Commission (IPC) in Ghaziabad hosts the National Coordination Centre (NCC). Local ADR Monitoring Centres (AMCs) support reporting. The IPC provides a suspected ADR form for health professionals and a medicine side-effect form for consumers. The reporting workflow turns usable case details into individual case safety reports (ICSRs). The programme uses VigiFlow in the reporting process and contributes reports to VigiBase, the global database maintained by the Uppsala Monitoring Centre (UMC).
| Safety concept | What it means |
|---|---|
| Safety signal | A suspected new risk or change in a known risk that merits investigation. A reporting pattern can generate a signal, but a spontaneous case series on its own cannot establish incidence. |
| Suspected unexpected serious adverse reaction (SUSAR) | A suspected causal reaction that is both serious and unexpected. Expectedness is assessed against the applicable reference safety information. A trial serious adverse event triggers the Indian rule 42 reporting obligation independently of a SUSAR classification. |
| Periodic safety update report (PSUR) | An aggregate safety report for a covered marketed new drug. The Fifth Schedule provides for six-monthly reports for the first two years and annual reports for the next two, with possible extension by the Central Licensing Authority. In its 21 April 2026 advisory, CDSCO directs manufacturers and importers to count from actual marketing when launch is delayed after approval. |
Causality assessment
The Naranjo algorithm scores evidence from the case. The categories are definite (9 or more), probable (5–8), possible (1–4) and doubtful (0 or below). For example, a score of 6 falls into the probable category under this algorithm.
The World Health Organization–Uppsala Monitoring Centre (WHO–UMC) method uses qualitative categories. It considers timing, competing explanations and information after stopping the drug (dechallenge). Its categories are certain, probable/likely, possible, unlikely, conditional/unclassified and unassessable/unclassifiable. In a possible case, the timing can fit while another drug or disease can also explain the event. A probable/likely case can be classified without rechallenge, which means exposing the patient again. The categories are not direct equivalents of Naranjo scores.
Pharmaceutical quality systems
Quality assurance (QA) covers the systems used to ensure medicines meet quality requirements, including controlled procedures, training, validation and change control. Quality control (QC) covers sampling, specifications, testing and the related procedures for product disposition. India’s revised Schedule M contains the pharmaceutical good manufacturing practices (GMP) and premises, plant and equipment requirements. The phased change took effect for manufacturers above ₹250 crore annual turnover in June 2024. The 2025 conditional extension for eligible smaller manufacturers ended on 31 December 2025.
Schedule L1 sets good laboratory practice and premises and equipment requirements for covered Indian drug-testing laboratories. The Organisation for Economic Co-operation and Development (OECD) principles of good laboratory practice (GLP) concern nonclinical health and environmental safety studies. The International Council for Harmonisation (ICH) Q7 guideline concerns GMP for active pharmaceutical ingredients. Match the type of work and jurisdiction to the relevant standard.
Quality by design
Under ICH Q8(R2), the quality target product profile (QTPP) describes the desired product characteristics. A critical quality attribute (CQA) is a property that must stay within an appropriate limit or range to assure quality. A critical process parameter (CPP) is a process variable whose variability affects a CQA. For a tablet, dissolution can be a CQA. If changes in compression force affect dissolution, compression force may be a CPP.
A design space describes combinations and interactions of inputs and process parameters demonstrated to assure quality. Under the ICH concept, movement within an approved design space is ordinarily not considered a regulatory change. The site still applies its pharmaceutical quality system.
Out-of-specification results
An out-of-specification (OOS) result falls outside the approved acceptance criteria. Revised Schedule M requires a documented investigation using an approved procedure. An initial laboratory review can assess calculations, equipment and sample handling. If it does not identify a cause, extend the investigation to manufacturing and sampling and consider effects on other batches. The US Food and Drug Administration guidance calls these two stages Phase I and Phase II. The terms describe the investigation model.
A passing repeat alone does not justify discarding a failing result. Preserve the original records and evaluate all results under the approved procedure. Corrective and preventive action (CAPA) addresses identified causes and evaluates whether actions worked. Change control evaluates and approves proposed changes. In qualification, installation qualification (IQ) checks installation, operational qualification (OQ) checks performance against operational requirements, and performance qualification (PQ) checks consistent performance under the intended conditions.
Environment and healthcare waste
An ecosystem includes interacting organisms and their physical environment. Energy passes from producers to consumers, and less energy is available at each higher trophic level. The school-level 10% transfer rule is an approximation. Biodiversity conservation can protect organisms within their habitats (in situ) or outside their habitats, such as in seed banks (ex situ).
The Indian Bio-Medical Waste Management Rules, 2016, as amended, use separate streams at the point of generation. Apply Schedule I to the waste and its contamination.
| Stream | Examples and handling principle |
|---|---|
| Yellow | Expired or discarded medicines, cytotoxic-contaminated items, and separate subcategories for anatomical and soiled waste. Use the treatment or return route specified for the particular waste. The rules give distinct disposal provisions for cytotoxic waste. |
| Red | Contaminated recyclable plastics such as used tubing and syringes without needles. Authorized treatment and recycling follow segregation. |
| White, translucent | Waste sharps such as needles and blades go in a puncture-proof, leak-proof, tamper-proof container. |
| Blue marking | Designated glassware, vials and ampoules without cytotoxic contamination, as well as metallic body implants. Use the specified puncture-proof, leak-proof box or container. |
A glass vial contaminated with cytotoxic medicine belongs in yellow under the discarded-medicines provision. An ordinary discarded glass vial in the designated glassware category goes in blue. Material and contamination both matter.
Effluent and oxygen demand
An effluent treatment plant (ETP) uses treatment steps selected for the wastewater. Biochemical oxygen demand (BOD) measures oxygen consumed by microbial activity over a specified time and temperature. Chemical oxygen demand (COD) expresses the oxygen equivalent of chemical oxidation under the test conditions. India’s effluent standard for bulk drugs and formulations specifies BOD measured over three days at 27 °C, and lists COD separately. The applicable standard depends on the discharge setting, including whether a common effluent treatment plant is used. BOD and COD are measured quantities and cannot be substituted for one another.
Sources
- Spontaneous reporting and case handling. IPC reporting · PvPI toolkit · IPC guidance for marketing authorization holders
- Safety definitions and timing. ICH efficacy guidelines · NDCT Rules, rule 42 and Fifth Schedule · CDSCO advisory on delayed marketing
- Assessment criteria. WHO–UMC · Naranjo et al.
- Indian GMP, including paragraph 19.6.7. Revised Schedule M · Implementation timeline
- Laboratory practice, pharmaceutical development and OOS investigation. OECD GLP principles · ICH quality guidelines · FDA investigation guidance
- Waste categories and effluent monitoring. Bio-Medical Waste Management Rules, Schedule I · 2026 amendment index · MoEFCC submission with G.S.R. 541(E)
- Trophic energy transfer. NCERT Class X environment exemplars
Which institution serves as the National Coordination Centre (NCC) for the Pharmacovigilance Programme of India (PvPI)?
Central Drugs Laboratory (CDL), Kolkata
National Pharmaceutical Pricing Authority (NPPA), New Delhi
Central Bureau of Narcotics (CBN), Gwalior
Indian Pharmacopoeia Commission (IPC), Ghaziabad
An initial laboratory investigation finds no assignable cause for a result outside the approved specification. What should the quality unit do next?
Discard the original test preparation and replace the result with fresh readings
Keep the result in the investigation and extend the review to sampling and manufacturing under the approved procedure
Average it with passing values until the batch mean meets specifications
Mark the batch compliant without investigating the discrepancy
Under the Biomedical Waste Management Rules, 2016, which color-coded container is designated for expired or discarded medicines and cytotoxic drugs?
Red bag
White translucent puncture-proof container
Yellow non-chlorinated bag or container
Blue puncture-proof box
Sections you finish are checked off in the contents.