7.2 Tablets, Capsules, Coating & Manufacturing Defects

Key Takeaways

  • Distinguish excipient functions and check performance under actual formulation and process conditions.

  • Choose wet granulation, dry granulation or direct compression by weighing stability, flow and uniformity risks.

  • Mass uniformity, content uniformity, friability, disintegration and dissolution measure different attributes. Use the named method.

  • Capping, lamination and coating defects have several possible causes. Match process changes to an investigation.

  • Estimate capsule fill volume from mass and fill density, then confirm the shell and equipment can deliver the required fill.

Last updated: November 2026

Tablets, Capsules, Coating & Manufacturing Defects

Quick Answer: Choose a formulation and process that can deliver uniform units. When a test fails or a defect appears, identify the measured attribute and investigate the failure mechanism before changing the process.

Preformulation and Tablet Excipients

Preformulation examines solid form, solubility, particle properties and the compatibility of the drug with excipients. Polymorphs can differ in dissolution. Compatibility must also be tested in the anticipated formulation, since some drugs react with lactose under certain conditions.

FunctionExamples and what to check
DiluentLactose, mannitol, microcrystalline cellulose or dibasic calcium phosphate provide bulk. Grade and particle properties affect compressibility and flow.
BinderPovidone, starch paste or suitable cellulose derivatives help particles form cohesive granules or tablets. Check whether binding impedes breakup.
DisintegrantSodium starch glycolate can swell, while croscarmellose can swell and promote water uptake. In visualization experiments, strain recovery was a dominant contributor for crospovidone. Check the formulation before assigning a mechanism or concentration.
LubricantMagnesium stearate or sodium stearyl fumarate reduces friction during compression or ejection. Extensive mixing with magnesium stearate can change tablet strength, wetting or dissolution.
GlidantColloidal silicon dioxide can improve powder flow. Its effectiveness depends on grade, amount and the powder blend.

Manufacturing Routes

RouteCharacteristic sequenceCheck before selecting
Wet granulationBlend, add granulating liquid, form granules, dry and size before final blending and compressionEffect of liquid and drying on stability, and whether the process improves distribution and flow
Dry granulationCompact the dry blend by slugging or roller compaction, then mill and size the compactsEffect of prior compaction on re-compressibility and granule properties
Direct compressionBlend and compress with no granulation stepDie filling, segregation risk, blend uniformity and tablet strength

In a rotary press, the sequence includes die filling, metering, compression and ejection. Precompression can reduce entrapped air for some formulations. Tooling size and shape affect tablet geometry and are matched to the press and product.

Compendial Tests and In-Process Controls

  • Mass uniformity: WHO International Pharmacopoeia 5.2, in the case covered by its test for uncoated and film-coated tablets, uses 20 tablets. At least 18 must be within ±10% for an average mass below 80 mg, ±7.5% for 80–250 mg inclusive, or ±5% above 250 mg. No unit may exceed twice its applicable limit. Check monograph applicability before using these thresholds.
  • Content uniformity: An individual-unit content test measures the amount of active ingredient in each sampled unit. A uniform mass does not establish uniform content if the blend is segregated. Use the named compendial rule or product monograph.
  • Breaking force and friability: Breaking force measures force to fracture. Friability measures loss of mass and damage during tumbling. In the WHO friability test, the drum makes 100 turns at 25 ± 1 rpm. For most products in scope, not more than 1.0% mass loss is acceptable, and visibly cracked, split or broken tablets fail. Use the product-specific criterion if given.
  • Disintegration versus dissolution: Disintegration tests physical breakup under specified conditions. Dissolution measures the amount of active ingredient going into solution at specified times. The basket and paddle are common dissolution apparatuses. The medium, speed, acceptance and sampling times depend on the method.

Worked example: A 6.50 g friability sample weighs 6.45 g after testing. The decrease is 0.05/6.50×100≈0.77%0.05/6.50\times100\approx0.77\%. This meets a criterion of not more than 1.0% if no tablets are visibly cracked, split or broken.

Tablet Defects and Coating

ObservationDefect and likely investigation
A top or bottom crown separatesCapping. Check entrapped air, elastic recovery, formulation and tool condition.
The tablet splits into layersLamination. Check decompression and air entrapment as well as moisture and forming conditions.
Material adheres to the tool or is pulled from a detailSticking or picking. Check moisture, die or punch finish and adhesion, especially around embossing.
Patchy colorMottling. Check color distribution and whether it changes during drying.
Broken edgesChipping. Check handling, ejection and tablet mechanical properties.

A study of air-entrapment lamination showed that a suitable precompression step could produce intact tablets under conditions that caused defects without it. Run a targeted investigation before changing the main compression force.

Coating choices: A conventional sugar coat builds up layers, while film coating applies a thin polymer film. Enteric polymers delay release in acid, but product performance must be tested. For example, the supplier describes Eudragit L 100 and S 100 as soluble above approximately pH 6 and 7, respectively. That polymer property does not itself establish the site of release.

A rough, pebbled film is called orange peel. Coating experiments show that spray-dried droplets that fail to coalesce can contribute. Bridging obscures recessed detail, blistering lifts the film from the surface, and twinning occurs when two tablets adhere during coating.

Capsules and Scale-Up

The WHO capsules monograph distinguishes hard and soft shells. Hard two-piece shells can contain suitable solids or liquids. A soft shell is made and sealed around the fill, so gel properties, plasticizer, fill composition and shell compatibility matter.

Worked example: Suppose a blend packs at 0.75 g/mL0.75\text{ g/mL} under the stipulated fill conditions. For a 0.375 g0.375\text{ g} fill, the estimated volume is 0.375/0.75=0.50 mL0.375/0.75=0.50\text{ mL}. A supplier's standard Size 1 has a nominal volume of 0.50 mL. Confirm actual fillability with the selected shell and machine before setting the process.

Scale-up checks whether process changes preserve attributes such as assay, content uniformity and dissolution. FDA's SUPAC-IR is a US framework for specified changes to immediate-release solid oral products. Its batch-size provisions have conditions, and the documentation and dissolution requirements depend on the change category. Establish the applicable Indian requirements separately for Indian submissions.

Test Your Knowledge

Under the WHO friability example with an acceptance criterion of not more than 1.0% mass loss, a 6.50 g tablet sample completes 100 turns. No tablet is visibly cracked, split or broken. Which test result meets the criterion?

A

6.45 g

B

6.40 g

C

6.35 g

D

6.30 g

Test Your Knowledge

A tablet has a rough, pebbled film. Microscopy shows that spray droplets dried before fusing on the surface. Which defect and mechanism fit these observations?

A

Bridging, caused by excessive plasticizer concentration

B

Orange peel, caused by premature droplet drying before film coalescence

C

Mottling, caused by high-speed punch embossing

D

Picking, caused by an enteric polymer dissolving at pH 7.0

Test Your Knowledge

Which statement accurately distinguishes tablet disintegration from dissolution?

A

Disintegration uses the rotating dissolution basket, and dissolution uses the disintegration basket-rack assembly

B

Disintegration measures active ingredient in solution, and dissolution measures physical breakup

C

Passing a disintegration test establishes that the dissolution specification is met

D

Disintegration tests physical breakup, while dissolution measures active ingredient entering solution

Sections you finish are checked off in the contents.