5.3 NMR, Mass Spectrometry, XRD & Thermal Analysis
Key Takeaways
NMR chemical shift in ppm is a frequency ratio. A first-order scalar coupling constant is reported in hertz.
EI often gives characteristic fragments for library matching. ESI and MALDI can preserve useful signals from larger molecules.
The nitrogen rule relates the nominal mass of a qualifying neutral organic molecule to the parity of its nitrogen count. Identify ion type before applying it.
Use half the measured 2θ angle in Bragg’s law. Powder diffraction can distinguish crystalline patterns and diffuse scattering.
DSC measures thermal events and TGA measures mass change. Use each measurement and orthogonal evidence to distinguish possible causes.
NMR, Mass Spectrometry, XRD & Thermal Analysis
NMR and molecular connectivity
Nuclei with a nonzero spin can give NMR signals under suitable conditions. Common spin-½ nuclei include ¹H, ¹³C, ¹⁹F and ³¹P. The magnitude of the Larmor frequency is for gyromagnetic ratio in angular frequency per tesla. For routine proton NMR referred to tetramethylsilane (TMS), the chemical shift can be expressed as
Use the same frequency units in numerator and denominator. If the frequency difference is in Hz and the reference frequency is in MHz, dividing their numerical values directly gives ppm. A shift of 2.00 ppm corresponds to about 600 Hz from the reference at 300 MHz and 1200 Hz at 600 MHz. The ratio remains 2.00 ppm. IUPAC NMR reference and shift conventions
| Observation or method | Interpretation |
|---|---|
| ¹H chemical shift | Alkyl signals commonly occur upfield of many aromatic and aldehydic signals. Solvent, exchange and local electronic environment affect positions. Exchangeable O–H or N–H signals can diminish after deuterium exchange. |
| Splitting in first-order spectra | An observed proton coupled to equivalent spin-½ neighbours with the same coupling can give lines. Strongly coupled systems can show more complicated patterns. |
| Scalar coupling | Report in Hz. A first-order 7 Hz splitting remains about 7 Hz at higher field when sample conditions are unchanged, whereas separation between chemical shifts in Hz increases. |
| ¹³C DEPT-135 | With conventional phase, CH and CH₃ are positive and CH₂ negative. Carbons without attached hydrogen are absent. Compare with a broadband proton-decoupled ¹³C spectrum to find the missing signals. |
| COSY and HSQC | COSY can connect coupled protons. HSQC commonly correlates protons with directly bonded heteronuclei such as ¹³C. HMBC can show longer-range correlations, commonly over two or three bonds. |
| NOE | A through-space effect that supplies proximity information under suitable conditions. Interpretation depends on molecular motion and the experiment. |
IUPAC spectrum conventions · Original DEPT study
Mass spectrometry and coupled methods
A mass spectrometer detects ions according to mass-to-charge ratio, . Ion production can occur at atmospheric pressure in sources such as electrospray, followed by transmission into the mass analyser.
| Method | Signal or analytical role |
|---|---|
| Electron ionization (EI) | Often generates a radical cation and characteristic fragment ions. A conventional energy for many GC–MS reference spectra is 70 eV. |
| Electrospray ionization (ESI) | Produces ions from charged droplets, often including protonated, deprotonated or multiply charged ions according to polarity and analyte. Useful with LC and for many polar molecules and biomolecules. |
| Atmospheric-pressure chemical ionization (APCI) | Commonly uses corona discharge and gas-phase ion–molecule processes. Useful for selected LC-compatible small molecules. |
| Matrix-assisted laser desorption/ionization (MALDI) | Uses a matrix and laser to assist desorption and ionization, often giving singly charged ions. It can be paired with time-of-flight analysis. |
| Triple quadrupole | In targeted reaction monitoring, select a precursor, fragment it in a collision cell and monitor selected product ions. |
| TOF and Orbitrap | TOF uses flight time. Orbitrap relates axial oscillation frequency to . Accurate mass can support a formula assignment alongside other evidence. |
The base peak is assigned 100% relative intensity. It can be a fragment. A one-chlorine isotope pattern often contributes peaks about two mass units apart in a ratio of roughly 3:1. One bromine gives a ratio near 1:1. Other isotopes and multiple halogens affect the full pattern.
The nitrogen rule applies to the neutral nominal mass for an organic molecule with the usual C, H, N, O, S, P and halogen elements. An odd nominal mass implies an odd number of nitrogen atoms within this scope. An identified singly charged EI molecular radical cation has the same nominal mass as the neutral precursor. A protonated ion has one additional nominal mass unit, so identify the ion type first. A McLafferty rearrangement is a characteristic fragmentation involving transfer of a gamma hydrogen and bond cleavage in suitable structures.
GC–MS combines gas separation and mass spectra. LC–MS/MS can separate analytes from some matrix components and monitor distinct precursor/product transitions. Each technique still requires selectivity and suitability for the intended analytical use. IUPAC mass spectrometry terminology · IUPAC nitrogen rule · Original electrospray study · Original MALDI study · Orbitrap study
X-ray powder diffraction and thermal methods
Bragg’s law relates lattice plane spacing to wavelength , angle and order :
A diffractometer commonly reports peaks at . Crystalline solids can show relatively sharp peaks linked to long-range order. Amorphous material generally produces more diffuse scattering. Compare patterns and control measurement conditions when looking for crystal-form differences. The appropriate tests for a particular solid-form specification depend on the material and product. Bragg original paper · ICH Q6A specifications and solid forms
| Thermal method | Measured signal and interpretation |
|---|---|
| DSC | Difference in energy input or heat flow between sample and reference under a controlled program. Can reveal endotherms, exotherms or a baseline step near a glass transition. |
| DTA | Difference in temperature between sample and reference during a thermal program. |
| TGA | Mass change during a controlled program. Volatilization, decomposition and other processes can change mass. |
Worked example. A first-order peak at with Å has Å. In a separate sample, suppose a molecular mass of 342.0 g/mol for the anhydrous material. A monohydrate would theoretically lose if all its water were evolved as the only mass loss. A coincident 5.00% TGA loss and DSC endotherm is consistent with that hypothesis. Use techniques such as evolved-gas identification and diffraction comparison to test it against alternatives. IUPAC thermogravimetry · IUPAC DSC
Electrophoretic methods
In capillary zone electrophoresis, migration reflects an analyte’s electrophoretic mobility and, when present, bulk electroosmotic flow. Charge, size and buffer conditions influence effective mobility. In SDS–PAGE, detergent-denatured proteins typically separate mainly by apparent molecular mass. A reducing agent can break disulfide bonds when the procedure calls for it. A measured migration band alone does not determine exact molecular mass or protein identity. Capillary electrophoresis study · Laemmli gel study
A drug made only of common organic elements covered by the nitrogen rule gives an identified, singly charged EI molecular radical cation at nominal m/z 251. What does the rule imply?
It contains an even number of nitrogen atoms (including zero)
It must contain at least one chlorine atom
It contains an odd number of nitrogen atoms
Its base peak must occur at an even mass-to-charge ratio
For a first-order NMR multiplet with sample conditions unchanged, which stated quantity remains approximately the same when moving from a 300 MHz to a 600 MHz instrument?
Chemical shift expressed in hertz (Hz) from TMS
Sensitivity (signal-to-noise ratio)
Dispersion between adjacent methylene signals in Hz
Spin-spin coupling constant J expressed in hertz (Hz)
A DSC endotherm coincides with a 4.8% mass loss on TGA. Evolved-gas analysis identifies water, and powder diffraction shows a different crystalline pattern after heating. Which interpretation is best supported?
Water loss accompanied by a change of crystalline form
Simple melting with no mass change
A glass transition alone with no volatile release
A mass-conserving solid–solid transition alone