9.3 Computer-Aided Drug Design (CADD), QSAR & Molecular Docking

Key Takeaways

  • Ligand-based design uses observations about known ligands. Structure-based design uses a three-dimensional target model.

  • A fitted Hansch equation can relate activity to lipophilic, electronic and steric descriptors. A negative quadratic term gives a model maximum within the applicable range.

  • Free–Wilson uses substituent indicators, Craig plots help choose diverse substituents, and Topliss schemes use observed activity to guide successive choices.

  • CoMFA compares aligned ligand interaction fields. CoMSIA uses smooth similarity fields. Docking pose recovery tests a different prediction task.

  • Lipinski and Veber thresholds are empirical screening heuristics. Solubility, permeability and oral bioavailability require separate evidence.

Last updated: November 2026

9.3 Computer-Aided Drug Design (CADD), QSAR & Molecular Docking

Ligand-based and structure-based design

ApproachInputOutput and limitation
Ligand-basedKnown structures with comparable activity measurements, or ligands with shared featuresA quantitative structure–activity relationship (QSAR) or a feature hypothesis. Predictions can degrade for new scaffolds or measurements made under different conditions.
Structure-basedA target structure from experiment or a suitable model, with a defined binding sitePlausible poses and scores. Target preparation, conformation and simplified scoring can affect the results.

A workflow can combine both approaches. Ligand activity can test a docking hypothesis. A target structure can help interpret a ligand-based model.

Hansch, Free–Wilson, Craig and Topliss

A Hansch-style equation can fit the biological response of related analogues to their lipophilic, electronic and steric descriptors:

log⁡10(1/C)=k1π−k2π2+ρσ+k3Es+c.\log_{10}(1/C)=k_1\pi-k_2\pi^2+\rho\sigma+k_3E_s+c.

Use the numerical value of CC in mol/L for compounds measured at the same specified response. The coefficients are fitted for the series. If k2>0k_2>0, the model response is maximized at π0=k1/(2k2)\pi_0=k_1/(2k_2) with the other descriptors held fixed. Apply the result only over a supported range. In an enzyme assay, a curved fit does not establish a membrane transport mechanism.

Worked example. Suppose a fitted model is 1.6π−0.4π2+0.8σ+4.21.6\pi-0.4\pi^2+0.8\sigma+4.2. The derivative with respect to π\pi is 1.6−0.8π1.6-0.8\pi, so the optimum occurs at π=2.0\pi=2.0. Its second derivative is negative. For an illustrative analogue with π=0.71\pi=0.71 and σ=0.23\sigma=0.23, substituting gives 5.318365.31836, so C=10−5.31836C=10^{-5.31836} mol/L, or about 4.8 µM. At π=σ=0\pi=\sigma=0, the model predicts about 63 µM. The numerical comparison assumes identical assay conditions.

MethodWhat it does
Free–WilsonFits contributions for substituents at specified positions using indicator variables. In one coding, y=μ+∑aijXijy=\mu+\sum a_{ij}X_{ij}, with a stated reference for each position. The additive assumption can miss interactions between groups.
Craig plotPlots two substituent descriptors, commonly σ\sigma and π\pi. Sampling across the plot can reduce confounding between them. Actual predictor correlations still need checking.
Topliss schemeUses the relative activity of successively tested analogues to choose the next substitution. A classical aromatic scheme starts by comparing phenyl with the para-chloro analogue.

Hansch and Fujita · Free and Wilson · Craig substituent selection · Topliss scheme assessment

Descriptor choice and three-dimensional models

DescriptorInterpretation
log⁡P\log P and log⁡D\log DIn drug design, log⁡P\log P commonly refers to the octanol/water partition ratio of the neutral species. log⁡D\log D includes all forms present at a specified pH.
Hansch π\piDifference in log⁡P\log P for a substituted molecule and its hydrogen reference in the defined series.
Hammett σ\sigmaElectronic constant relative to hydrogen, based on the appropriate substituted benzoic acid equilibrium. Specify the position because meta and para constants can differ.
Taft EsE_sEmpirical steric constant derived from relative ester hydrolysis rates using the defined reference and conditions.
Size and shapeMolar refractivity relates size to polarizability. Directional steric descriptors instead describe widths and length relative to a defined bond axis.

A pharmacophore describes the spatial arrangement of features relevant to molecular recognition. Features can include hydrogen-bond donors or acceptors, hydrophobic regions and charge. An excluded volume can represent space occupied by the target. IUPAC pharmacophore definition

CoMFA aligns related ligands and samples steric and electrostatic probe interactions on a grid. The classical descriptors use Lennard–Jones and Coulomb-type functions. CoMSIA uses smooth Gaussian distance dependence and can include steric, electrostatic, hydrophobic, hydrogen-bond donor and acceptor fields. Both depend on alignment, conformations and the quality of the measured endpoint. Cross-validation measures a chosen internal prediction task. Assess performance against independent compounds and describe the applicability domain before extrapolating. CoMFA study · CoMSIA field study · OECD QSAR assessment framework

Docking and virtual screening

Docking samples ligand orientations and conformations in a binding site. Some settings keep the receptor fixed, while others allow selected receptor movements. Scoring functions rank poses or compounds using approximations to the interactions. A score alone cannot establish measured binding affinity.

A pose-recovery check can redock a ligand whose structure in the pocket was determined experimentally and compare matched heavy-atom positions. For example, a benchmark can prespecify an RMSD criterion of 2 Å and account for equivalent atoms when evaluating it. Recovery of one reference pose supports a limited geometric check. Enrichment of known actives or ranking by experimental affinity requires other tests. Docking benchmark

Oral-property screening

  • Lipinski’s rule of five. The familiar thresholds are molecular mass at most 500 Da, calculated log P at most 5, at most five hydrogen-bond donors and at most ten hydrogen-bond acceptors. The original work links values beyond the limits to a greater likelihood of poor absorption or permeation and distinguishes calculated lipophilicity scales.
  • Veber criteria. A study in rats associated better oral bioavailability with at most ten rotatable bonds and polar surface area at most 140 Ų, or with the stated alternative of at most 12 donors plus acceptors. Use the descriptors and conventions specified by a question or tool.

A hypothetical compound with molecular mass 510 Da, log P 4, three donors, nine acceptors, seven rotatable bonds and polar surface area 102 Ų exceeds the Lipinski mass cutoff alone and meets the two Veber limits. That comparison identifies which descriptor to investigate. It does not give a measured bioavailability. Lipinski study · Veber study

Test Your Knowledge

In the fitted model log(1/C) = 1.6pi − 0.4pi^2 + 0.8*sigma + 4.2, at what value of pi is the fitted response maximal with sigma held fixed?

A

0.4

B

2.0

C

3.2

D

4.0

Test Your Knowledge

How does CoMSIA primarily differ from CoMFA in 3D-QSAR modeling?

A

CoMSIA uses 2D substituent constants without superimposing 3D ligand conformations

B

CoMSIA replaces steric and electrostatic descriptors entirely with molecular weight and TPSA

C

CoMSIA applies smooth Gaussian-type distance functions and evaluates hydrophobic and hydrogen-bond fields alongside steric and electrostatic fields

D

CoMSIA requires an experimental protein crystal structure to calculate docking scores

Test Your Knowledge

Which descriptor set satisfies all four standard Lipinski cutoffs and both Veber cutoffs using polar surface area?

A

MW = 380 Da, log P = 3.2, HBD = 2, HBA = 6, rotatable bonds = 5, TPSA = 82 square Angstroms

B

MW = 490 Da, log P = 4.8, HBD = 4, HBA = 9, rotatable bonds = 13, TPSA = 155 square Angstroms

C

MW = 620 Da, log P = 6.1, HBD = 6, HBA = 12, rotatable bonds = 8, TPSA = 110 square Angstroms

D

MW = 450 Da, log P = 5.6, HBD = 7, HBA = 11, rotatable bonds = 9, TPSA = 125 square Angstroms

Sections you finish are checked off in the contents.