Key Takeaways
Separate release from systemic input when calculating maintenance delivery. Include the systemic fraction when the problem provides it.
Use Higuchi square-root kinetics only within the matrix model assumptions.
In a conventional elementary osmotic pump, water enters through the membrane and drug leaves through the delivery opening.
Distinguish phospholipid liposomes from nonionic-surfactant niosomes by membrane composition.
Patch, implant and targeted delivery performance depends on the formulation and the physiologic setting.
Novel & Controlled Drug Delivery Systems (NDDS)
Quick Answer: Identify what controls release. A matrix can lengthen the diffusion path, a reservoir can control transport through a membrane, and an osmotic pump can use water influx to drive delivery. The dosage form's release profile and systemic drug input can differ.
Modified Release and Drug Input
Modified-release products can delay release, extend it or provide a designed sequence of release rates. Zero-order release is a special case with constant mass released per unit time during the modeled interval. Some modified-release products use a faster initial phase followed by a slower or changing release phase.
At steady state with linear elimination, the systemic input rate is . If a constant fraction of the drug released from an oral device reaches systemic circulation with negligible delay under the exercise conditions, . A steady-state calculation gives the maintenance input. Reaching the target at the beginning of an interval requires an appropriate initial condition.
Worked example: Suppose clearance is 4 L/h, the target is 5 mg/L and the assumed systemic fraction of oral release is . The required systemic input is . Thus the device must release , or 300 mg over 12 hours. This model assumes those inputs remain constant over the specified interval.
Matrix and Reservoir Release
- Matrix: Drug is dispersed through a material. Under the classical planar Higuchi model with excess suspended drug, constant transport properties and a sink outside the matrix, cumulative release per area is proportional to . Swelling, erosion or a change in geometry can alter this relationship.
- Reservoir: A membrane surrounds a drug-containing core. When membrane transport is rate-limiting, the membrane properties and driving force stay constant, and the outside is a sink, flux can be approximately constant. Membrane damage can change delivery.
Handling instructions are product-specific. For example, the CONCERTA label directs swallowing the tablet whole. Follow the product instructions when a patient has difficulty taking a modified-release dose.
Osmotic Devices, Encapsulation and Targeted Oral Release
In the elementary osmotic pump, water enters across the semipermeable membrane. The incoming water creates pressure and drug solution exits through the delivery opening. A nearly constant rate is possible while membrane transport, the osmotic gradient and internal drug concentration remain suitable. The original experiments found that the tested release rate was insensitive to external pH or agitation under the studied conditions. Food effects and in vivo absorption need separate evidence for each product.
A push–pull osmotic design can combine a drug layer and a swelling push layer to expel a formulation. Osmotic products can be engineered for different profiles. The cited CONCERTA product has an immediate-release overcoat and an osmotic core whose release increases over part of the dosing interval.
Microencapsulation applies a wall or coating around a core. It can protect a payload, mask taste or change release. Coacervation deposits a polymer-rich phase onto a core, spray drying forms particles as droplets dry, and fluid-bed coating can deposit a film on existing particles. Demonstrate the properties of the resulting product for the chosen method.
| Design goal | Mechanism and limitation |
|---|---|
| Gastroretention | Floating, mucoadhesive or expandable designs aim to prolong residence in the stomach. Retention can vary with physiological conditions and the formulation. |
| Delayed intestinal release | A pH-responsive coating can delay release. Gastrointestinal pH varies along the tract and between individuals, so a polymer threshold does not establish an exact anatomical release site. |
| Bacterial activation | Intestinal bacteria cleave the azo linkage of sulfasalazine to yield sulfapyridine and 5-aminosalicylic acid. This is a prodrug example. |
Transdermal and Implantable Delivery
A drug-in-adhesive patch can have backing, drug-containing adhesive and a removable liner. A reservoir design can also include a distinct rate-controlling membrane. Patch size, skin permeability, drug stability and the required dose affect feasibility. Molecular weight and lipophilicity can guide screening, but no single cutoff guarantees delivery.
In a simple steady-state model with a uniform barrier of thickness and a downstream sink, flux can be approximated as for partition coefficient , diffusivity and vehicle-side concentration . A patch can also impose its own transport resistance. Follow directions for the actual product and confirm which part of the system controls delivery.
Subdermal implants and intrauterine drug-delivery systems can release drug over extended periods. For example, etonogestrel can be delivered from a subdermal rod, and levonorgestrel can be delivered by a medicated intrauterine system. The duration and administration depend on the product.
Vesicles and Other Carriers
| Carrier | Architecture and interpretation |
|---|---|
| Liposome | One or more lipid bilayers surround an aqueous compartment. Water-soluble and lipid-soluble payloads can associate with different parts of the vesicle. The DOXIL label illustrates encapsulated doxorubicin in a PEGylated liposome. |
| Niosome | A vesicle formed using nonionic surfactants as major bilayer components. Some formulations include cholesterol. |
| Polymeric particle | A nanosphere can distribute payload within a polymer matrix, while a nanocapsule can have a distinct core and shell. |
| Solid lipid particle | Uses a solid lipid matrix stabilized as a dispersion. |
| Dendrimer | Uses a branched macromolecular architecture with multiple surface groups that can be functionalized. |
Passive accumulation relies on tissue and carrier properties, such as permeability and retention that can vary among tumors. A surface ligand can be designed to interact with a target, but the presence of the ligand alone does not establish successful targeting in patients.
Under conditions that give nearly constant release from an elementary osmotic pump, how do water and drug move?
Water and drug both leave through the outer membrane by the Higuchi mechanism
Drug leaves only after colonic bacteria cleave the outlet
Water enters through the delivery opening and drug crosses the intact semipermeable membrane
Water enters through the semipermeable membrane and the resulting pressure drives drug solution through the delivery opening
How do niosomes differ structurally from classical liposomes while serving a comparable vesicular carrier role?
Niosomes are hyperbranched dendrimers lacking an aqueous core
Niosomes use nonionic surfactants as major bilayer components, while classical liposomes use phospholipids
Niosomes contain a solid crystalline lipid core instead of a bilayer
Niosomes can encapsulate only lipophilic drugs and exclude hydrophilic solutes
A device is delivering drug at steady state. Clearance is 5 L/h, the target concentration is 4 mg/L, and all released drug reaches systemic circulation in this model. What mass must the device release over 10 hours?
20 mg
100 mg
200 mg
400 mg
Sections you finish are checked off in the contents.