Cheat sheet

VA Journeyman Electrician Cheat Sheet

VA Board Regulations (18VAC50-30)

14%of exam

Licensing & RenewalStandards & ConductReciprocityState Overrides National

General Knowledge & Fundamentals

10%of exam

Ohm's & Watt's LawSeries vs ParallelAC vs DCNEC Chapter Map

Branch Circuits & Load Calcs

9%of exam

AFCI/GFCI LocationsSABC RulesContinuous Load 80%Load Calculations

Services & Feeders

7%of exam

Service DisconnectsDwelling Minimum 100AService vs FeederGeneral Lighting Load

Grounding & Bonding

9%of exam

Grounding ElectrodesGEC & EGC SizingGrounding vs BondingElectrode Picker

Conductors & Cables

10%of exam

Table 310.16Ampacity vs OCPDInsulation TypesAdjustment Factors

Raceways & Boxes

10%of exam

Box FillConduit Fill %Bend LimitRaceway Picker

Motors, Transformers & Controls

7%of exam

Overload SizingBranch-Circuit SizingMotor Circuit PickerTransformer Protection

Special Occupancies & Equipment

9%of exam

Hazardous LocationsPoolsHealthcare SpacesSigns

Utilization, Lighting & Low-Voltage

13%of exam

Luminaire ClearancesAppliance DisconnectsClass 2/3 CircuitsEmergency vs Standby

Electrical Safety

6%of exam

Working SpaceArc Flash BoundariesNFPA 70E PPEHeadroom Rule

Quick Facts

Exam
VA Journeyman Electrician
Questions
70 multiple-choice
Time
210 min (3.5 hrs)
Pass
49 of 70 (70%)
Format
Open book
Code
NEC 2020
Admin
PSI for DPOR
Fee
$100 + $171.75

Journeyman vs Master Scope

Journeyman

  • Works under supervision
  • Performs installations
  • Passes journeyman exam

Master

  • Can supervise/contract
  • Broader scope of work
  • Separate master exam

Supervised work vs oversight

Licensing & Renewal

Governing reg
18VAC50-30
License term
3 years
Renewal CE
3 hrs code update
Reinstatement window
24 months, else new app
License transfer
Not assignable
Address change
Report within 30 days
Administrator
PSI for DPOR
Apprenticeship
Exempts journeyman exam

Standards, Conduct & Reciprocity

Abandonment
30+ days unjustified stop
Discipline triggers
Negligence, incompetence, misrepresentation
Reference rule
State overrides national
Open book
No exam-day writing
Tabs
Permanent only, no loose
Reciprocity (journeyman)
DC, KY, WV
Reciprocity (master)
AL, MD, NC, OH
Universal recognition
3+ yr license, no discipline

NEC Chapter Map

Ch2 Wiring, Ch3 Methods, Ch4 Equipment

Ch 2: wiring/protectionCh 3: methods/materialsCh 4: equipmentCh 5: special occupancies

Which NEC Article Covers It?

  1. Grounding/bonding questionArticle 250
  2. Branch-circuit ruleArticle 210
  3. Feeder/load calcArticle 220
  4. Service equipmentArticle 230
  5. Conductor ampacityArticle 310
  6. Box or conduit fillArt 314 / Ch 9
  7. Motor circuitArticle 430
  8. Swimming poolArticle 680
  9. Healthcare patient spaceArticle 517
  10. Hazardous classified locationArticle 500

Electrical Theory

Ohm's Law
E = I x R
Watt's Law
P = E x I
Series circuit
R adds, current shared
Parallel circuit
R drops, voltage shared
AC
Reverses direction, 60 Hz
DC
One direction only
Power factor
True power / apparent

Feeder vs Branch Circuit

Feeder

  • Supplies panelboards
  • No utilization equipment
  • Sized by demand load

Branch circuit

  • Supplies outlets/equipment
  • Ends at utilization equipment
  • Sized by connected load

Distribution vs final circuit

Branch Circuit Protection

AFCI rooms
Bedrooms, living areas, kitchens
AFCI exclusions
Baths, garages, unfinished basement
SABC count
2 circuits, 20A each
SABC scope
Kitchen/pantry/dining receptacles only
Continuous load
Max 80% of rating
100%-rated ckt
Needs listed equipment
Multiwire branch
Shared neutral, common trip
14 AWG limit
15A circuits only

GFCI vs AFCI

GFCI

  • Detects ground fault
  • Protects from shock
  • Wet/damp locations

AFCI

  • Detects arc fault
  • Protects from fire
  • Habitable rooms

Shock protection vs fire protection

Load Calculations

General lighting
3 VA per sq ft
Floor area
Outside dimensions
Excluded areas
Porches, garages, unfinished space
Standard method
Article 220 Part III
Optional method
220.82, single dwelling
Range demand
Table 220.55

Service vs Feeder

Service

  • Utility to disconnect
  • Ends at service equipment
  • One set per building

Feeder

  • Disconnect to branch OCPD
  • Can start anywhere downstream
  • Multiple feeders allowed

Where the run starts

Services & Feeders Basics

Service
Utility to disconnect
Feeder
Disconnect to branch OCPD
Disconnect count
1 default, up to 6
Grouping rule
Separate enclosures required
Dwelling minimum
100A, 3-wire
Service conductors
Sized to calculated load

Grounding Electrode Order

Water pipe, then Ufer, ring, or rod

Use what's already presentUfer: rebar in footingRing: buried bare copperRod: 8 ft driven

Grounding vs Bonding

Grounding

  • Connects to earth
  • Uses an electrode
  • Limits voltage to ground

Bonding

  • Joins metal parts
  • Keeps continuity
  • Clears fault current

Earth path vs metal path

Pick a Grounding Electrode

  1. Metal water pipe presentUse as electrode(10 ft+ contact)
  2. Rebar in footingUfer ground(20 ft min)
  3. No natural electrodeDriven ground rod(8 ft min)
  4. Only gas piping presentNot a valid electrode
  5. Multiple electrodes existBond them together(250.50)

Grounding Electrodes

Water pipe
10 ft+ underground contact
Ufer ground
20 ft rebar or wire
Ground ring
20 ft bare copper loop
Ground rod
8 ft, 5/8 in min
Listed rod
Smaller diameter allowed
Gas piping
Not a valid electrode
Multiple electrodes
Must bond together

Bonding & Conductor Sizing

Grounding
System-to-earth connection
Bonding
Metal parts joined, continuous
GEC size
Table 250.66, by service
EGC size
Table 250.122, by OCPD
Main bonding jumper
At service only
System bonding jumper
Separately derived systems

Ampacity vs OCPD Rating

Ampacity

  • Table 310.16 value
  • Based on insulation temp
  • Conductor's safe current

OCPD rating

  • Breaker or fuse size
  • Rounds to standard size
  • Protects the conductor

What wire carries vs what trips

Conductor Ampacity

Table 310.16
Base ampacity table
60/75/90C columns
Match insulation rating
Termination cap
110.14(C) limits final rating
100A rule
60C unless otherwise marked
Adjustment (4-6)
80% of table value
Adjustment (7-9)
70% of table value
Ambient correction
Table 310.15(B)(1)

Conductor & Insulation Types

THHN
90C dry/damp only
THWN
75C wet locations
THWN-2
90C wet and dry
12 AWG Cu
Min for 20A circuit
14 AWG Cu
Min for 15A circuit
Grounded conductor
White or gray
EGC
Green or bare

Box Fill Build Order

Wires, then devices x2, clamps and EGC as one

Conductors: actual countDevice: 2x its sizeClamps: one allowanceEGC: one allowance

Choose a Raceway

  1. Wet, corrosive, undergroundPVC conduit(needs separate EGC)
  2. Need extra physical protectionRMC
  3. Standard indoor branch wiringEMT(metal path bonds)
  4. Flexible near vibration, wetLFMC
  5. Flexible, dry locations onlyENT

Box Fill

14 AWG
2.00 in3 per conductor
12 AWG
2.25 in3 per conductor
10 AWG
2.50 in3 per conductor
Device (switch/recep)
2x largest connected wire
All EGCs
1 allowance, largest size
All clamps
1 allowance total
Fixture stud/hickey
1 allowance per size

Conduit Fill & Bends

1 conductor
53% fill max
2 conductors
31% fill max
3+ conductors
40% fill max
Bend limit
360 deg between pulls
EMT
Thin-wall, unthreaded
RMC
Thick-wall, threaded
PVC
Nonmetallic, needs separate EGC

Motor Overload Percentage

High SF or low rise: 125%, else 115%

SF >= 1.15: 125%Temp rise <= 40C: 125%Otherwise: 115%Base = nameplate FLA

Size a Motor Circuit

  1. Need motor FLCTable 430.247-250(Not nameplate)
  2. Size branch conductor125% of FLC(430.22)
  3. Motor SF >= 1.15125% FLA overload(430.32(A)(1))
  4. Motor SF < 1.15115% FLA overload
  5. Place disconnectWithin sight or lockable
  6. Multiple small motorsGroup circuit if listed(430.53)

Motor Sizing

Branch conductor
125% of table FLC
FLC source
Tables 430.247-430.250
Overload (SF>=1.15)
125% of nameplate FLA
Overload (SF<1.15)
115% of nameplate FLA
Disconnect location
Within sight or lockable
Group motors
Allowed under 430.53 limits
Transformer protection
Table 450.3 percentages

Class I vs Class II Locations

Class I

  • Flammable gas or vapor
  • Paint booths, fuel areas

Class II

  • Combustible dust
  • Grain, flour facilities

Gas/vapor vs dust

Special Occupancies

Class I
Flammable gas or vapor
Class II
Combustible dust
Division 1
Hazard normally present
Division 2
Hazard abnormal only
Pool bonding
3 ft perimeter, 4 pts
Patient care EGC
Insulated copper, redundant path
Sign disconnect
Within sight or lockable

Emergency vs Standby Systems

Emergency (Art 700)

  • Life safety loads
  • 10-second transfer

Legally required standby (701)

  • Required by code/authority
  • Longer transfer allowed

Life safety vs required backup

Utilization Equipment & Lighting

Closet surface fixture
12 in clearance
Closet recessed fixture
6 in clearance
Recessed non-IC housing
3 in from insulation
Housing clearance
1/2 in from wood
Appliance disconnect
In-sight switch or lockable
Utilization equipment
Uses power, doesn't distribute

Low-Voltage & Communications

Class 2/3
Power-limited, Article 725
Communications
Article 805, primary protector
Fire alarm NPLFA
Non-power-limited, Article 760
Fire alarm PLFA
Power-limited, Article 760
CATV
Article 820

Electrical Safety

0-150V working space
3 ft, all conditions
151-600V Cond 1
3 ft depth
151-600V Cond 2
3.5 ft depth
151-600V Cond 3
4 ft depth
Working width
30 in minimum
Headroom
6.5 ft (78 in)
Arc flash assessment
Before energized-equipment work
Approach boundaries
Limited, restricted, arc flash

Common Traps

Bathroom AFCI assumption

Bathroom needs GFCI only AFCI excludes bathrooms

14 AWG on 20A breaker

14 AWG maxes at 15A 20A needs 12 AWG

Nameplate vs table FLC

Nameplate sizes overload only Table sizes branch conductor

PVC self-grounding myth

PVC is nonmetallic Needs separate EGC wire

Reciprocity assumption

DC/KY/WV is journeyman only VA exam still required

Open book misconception

No writing on exam day Permanent tabs only

Retake wait myth

No 3-fail wait period Just seat availability limit

Last Minute

  1. 1.70 questions, 210 minutes, 49 pass
  2. 2.Open book: bring NEC, 70E, regs
  3. 3.Permanent tabs only, no loose pages
  4. 4.State-specific rule beats national rule
  5. 5.AFCI = habitable rooms; GFCI = wet areas
  6. 6.12 AWG minimum on 20A circuits
  7. 7.Box fill: 14g 2.0in, 12g 2.25in
  8. 8.Motor branch conductor = 125% table FLC
  9. 9.Overload 125% high SF, else 115%
  10. 10.Ground rod: 8 ft, 0.625 in
  11. 11.License: 3-year term, 3 CE hrs
  12. 12.Journeyman reciprocity: DC, KY, WV only
Same family resources

Explore More Electrician License

Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.