General Inspection Administration
18%of exam
General Provisions for Fire Safety
48%of exam
Occupancies
17%of exam
Regulated Materials and Processes
17%of exam
Quick Facts
- ICC exam
- 66 · National Certification
- Questions
- 60 multiple-choice
- Time limit
- 2 hours
- Format
- Open book
- Passing score
- 75 scaled
- Code editions offered
- 2021 and 2024
- Code books
- IFC and IBC, selected edition
- IFSTA manual
- Fire Inspection & Code Enforcement, 9th
- Delivery
- PRONTO in-person or remote
- Digital exam references
- IFC and IBC
Inspection Report Memory
Where, what, code, correction, follow-up
Operational vs Construction Permit
Operational permit
- Regulated activity or operation
- IFC §105.5
Construction permit
- Installation or modification scope
- IFC §105.6
Check both permit categories
Inspection Response Picker
- New regulated operation proposed→Check operational permit triggers(IFC §105.5)
- System installation or alteration planned→Check construction permit triggers(IFC §105.6)
- Permit work requires plans→Review construction document requirements(IFC §106)
- Access refused→Follow lawful entry process(IFC §104.4)
- Violation observed→Record facts and cite requirement(Use written notice procedure)
- Interpretation formally disputed→Follow local appeal procedure(IFC §112)
Permits and Plans
- Operational permit
- Regulates listed activities and operationsIFC §105.5
- Construction permit
- Covers listed installations or alterationsIFC §105.6
- Construction documents
- Review scope and required detailsIFC §106
- Plan revision
- Review changes through approval processIFC §106
- Field comparison
- Use latest approved drawingsIFC §109
- Code research
- Check adoption, scope, referenced standards
Inspection and Enforcement
- Complaint intake
- Record allegation and exact location
- Right of entry
- Request lawful accessIFC §104.4
- Inspection report
- Record condition, location, code basis
- Inspection records
- Retain findings and follow-upIFC §104.7
- Violation notice
- Document required correctionIFC §113
- Reinspection
- Verify and record correction
- Appeal
- Route disputed interpretation through processIFC §112
- Legal testimony
- Use factual observations and records
- Public inquiry
- Explain requirement and applicable citation
Egress Sequence
Access → Exit → Discharge
Common Path vs Travel Distance
Common path
- Ends at route choice
- IFC §1006.2.1
Exit access travel distance
- Ends at an exit
- IFC §1017
Measure to the correct endpoint
Egress Lookup Picker
- Single path before a choice→Check common path limit(IFC §1006.2.1)
- Farthest point to exit→Measure exit access travel(IFC §1017)
- Exit number in question→Check space and story rules(IFC §1006)
- Exit door difficult to open→Check operation and locking rules(IFC §1010)
- Emergency lighting in question→Check illumination requirements(IFC §1008)
- Stock blocks required route→Check egress maintenance(IFC §1032)
Means of Egress
- Exit access
- Travel leading to an exit
- Exit
- Protected path to exit discharge
- Exit discharge
- Exit termination to public way
- Common path
- Travel before two distinct routesIFC §1006.2.1
- Exit access travel distance
- Measure along path to exitIFC §1017
- Egress capacity
- Load × applicable capacity factorIFC §1005
- Stairway base capacity factor
- 0.3 in. per occupantIFC §1005.3.1
- Other egress base capacity factor
- 0.2 in. per occupantIFC §1005.3.2
- Exit count
- Check space and story rulesIFC §1006
- Exit separation
- Check required remotenessIFC §1007
- Egress lighting
- Check normal and emergency illuminationIFC §1008
- Door operation
- Check locks, latches, panic hardwareIFC §1010
- Exit signs
- Verify required locations and visibilityIFC §1013
- Existing egress upkeep
- Keep required routes clearIFC §1032
Acceptance vs Ongoing Maintenance
Acceptance
- New installation performance
- IFC §901.5
Ongoing maintenance
- Existing system reliability
- IFC §901.6
Match evidence to inspection purpose
System and Preparedness Picker
- New system installation complete→Verify required acceptance testing(IFC §901.5)
- Equipment differs from approved plan→Document and resolve discrepancy(Compare approved revisions)
- Existing system service uncertain→Check condition and maintenance records(IFC §901.6)
- Required system out of service→Follow impairment notification procedures(IFC §901.7)
- Tested water supply in question→Review flow and pressure data(IFC §507)
- Need to determine plan applicability→Check occupancy-based requirements(IFC §403)
- Required drill history uncertain→Check drill records and frequency(IFC §405)
Fire Protection Lookup
- Sprinklers
- Automatic fire suppressionIFC §903
- Other extinguishing systems
- Special-agent or application-specific protectionIFC §904
- Standpipes
- Water through hose connectionsIFC §905
- Portable extinguishers
- Check hazard, rating, placementIFC §906
- Fire alarm and detection
- Initiation, notification and system controlsIFC §907
- Smoke control
- Manage smoke movementIFC §909
- Fire department connection
- Fire service supplies system waterIFC §912
- Fire pump
- Provides required system pressureIFC §913
- Existing building requirements
- Check specific retrofit triggersIFC Ch. 11
Supervisory vs Trouble Signal
Supervisory
- Monitored condition off normal
- Example: valve position change
Trouble
- System fault indication
- Example: circuit fault
Identify the initiating condition
System Readiness
- Approved system plan
- Match installed equipment and layout
- Acceptance test
- Verify installation performanceIFC §901.5
- Ongoing readiness
- Review inspection, testing, maintenance recordsIFC §901.6
- Sprinkler control valve
- Verify normal open positionIFC §903.4
- Sprinkler supervisory signal
- Investigate off-normal monitored condition
- Alarm trouble signal
- Investigate system fault
- Alarm notification appliance
- Warn occupants audibly or visiblyIFC §907.5
- System impairment
- Notify and follow impairment proceduresIFC §901.7
- Impairment response
- Fire watch or evacuation, as directedIFC §901.7
Fire Service Access and Water
- Apparatus route
- Check access, clearance, obstructionsIFC §503
- Premises identification
- Verify visible address numbersIFC §505
- Key box
- Check required responder accessIFC §506
- Water supply
- Verify available fire protection supplyIFC §507
- Water supply test
- Review approved test resultsIFC §507.4
- Static pressure
- Pressure before test flow
- Residual pressure
- Pressure during test flow
- Hydrant access
- Keep approach and clearance openIFC §507.5
- Fire-flow benchmarks
- Check locally adopted requirementsIFC App. B
Emergency Preparedness
- Plan applicability
- Identify occupancy and triggerIFC §403
- Evacuation plan
- Routes, evacuation roles, occupant accountingIFC §404
- Fire safety plan
- Hazards, safeguards and response assignmentsIFC §404
- Evacuation drills
- Check frequency and participationIFC §405
- Drill records
- Check date, participants and resultsIFC §405
- Employee training
- Prevention and emergency dutiesIFC §406
- Hazardous field condition
- Document and escalate under authority
Construction Types
- Types I and II
- Generally noncombustible listed elementsIBC §602.2
- Type III
- Generally noncombustible exterior wallsIBC §602.3
- Type IV
- Mass timber or noncombustible elementsIBC §602.4
- Type V
- Code-permitted structural materialsIBC §602.5
- Element fire-resistance ratings
- Check type and subtypeIBC Table 601
- Height and area
- Check use, type, sprinkler protectionIBC Ch. 5
- Fire-resistance features
- Verify barrier openings and penetrationsIFC Ch. 7
Occupant Load Memory
Function picks factor, area supplies numerator
Gross vs Net Floor Area
Gross
- Generally includes accessory circulation
- Use gross factor where listed
Net
- Actual occupied area
- Excludes unoccupied accessory areas
Use the table's area basis
Occupancy Inspection Picker
- Tenant activity has changed→Reevaluate occupancy and approvals(IBC Ch. 3)
- Multiple uses share building→Check mixed-occupancy provisions(IBC §508)
- Area without fixed seats→Divide area by function factor(Use specified gross or net)
- Individual fixed seats installed→Count installed seats(Include applicable unseated areas)
- Assembly load sign missing→Check posting requirement(IFC §1004.9)
- Need occupancy-specific protection→Check applicable sprinkler and alarm triggers(IFC §§903, 907)
Occupancy Groups
- Group A
- AssemblyIBC §303
- Group B
- BusinessIBC §304
- Group E
- EducationalIBC §305
- Group F
- Factory and industrialIBC §306
- Group H
- High hazardIBC §307
- Group I
- InstitutionalIBC §308
- Group M
- MercantileIBC §309
- Group R
- ResidentialIBC §310
- Group S
- StorageIBC §311
- Group U
- Utility and miscellaneousIBC §312
- Mixed occupancies
- Check accessory, nonseparated, separated provisionsIBC §508
Occupancy vs Construction Type
Occupancy group
- Use and associated hazards
- IBC Chapter 3
Construction type
- Materials and element ratings
- IBC Chapter 6
Classify both before applying limits
Occupant Load
- Classification input
- Actual use and activities
- Area-based load
- Applicable floor area ÷ factorIFC §1004.5
- Factor lookup
- Match function and area basisIFC Table 1004.5
- Assembly chairs only, unfixed
- 7 net ft² per occupantIFC Table 1004.5
- Assembly tables and chairs
- 15 net ft² per occupantIFC Table 1004.5
- Tables and chairs example
- 300 ÷ 15 = 20 occupants300 ft² net
- Fixed seating
- Seats plus applicable unseated loadIFC §1004.6
- Bench seating without divisions
- One person per 18 inchesIFC §1004.6
- Booth seating
- One person per 24 inchesIFC §1004.6
- Intervening egress route
- Account for combined occupant loadsIFC §1004.2
- Assembly capacity sign
- Verify required occupant-load postingIFC §1004.9
Hazard Quantity Memory
Hazard, amount, activity, area
Storage vs Use
Storage
- Materials held for later use
- Check storage column
Use
- Materials handled in process
- Select open or closed use
Check aggregate limits and footnotes
Hazards Lookup Picker
- Torch cutting proposed→Check hot work safeguards(IFC Ch. 35)
- Spray operation observed→Check spray finishing requirements(IFC Ch. 24)
- Tall racks of combustibles→Check high-piled storage applicability(IFC Ch. 32)
- Hazardous materials being dispensed→Identify open or closed use(Select quantity column)
- Inventory exceeds applicable limit→Check high-hazard classification(Verify adjustments and exceptions)
- Wall finish replaced→Check permitted finish classification(IFC §803)
Process and Storage Lookup
- Commercial cooking
- Extinguishing protection and hood upkeepIFC §§606, 904.14
- Spray finishing
- Check ventilation and ignition controlIFC Ch. 24
- High-piled combustible storage
- Check commodity, arrangement and protectionIFC Ch. 32
- Welding and other hot work
- Check permit applicability and safeguardsIFC Ch. 35
- Compressed gas cylinders
- Check securement and valve protectionIFC Ch. 53
- Flammable and combustible liquids
- Check classification, storage, dispensingIFC Ch. 57
- Combustible waste
- Control accumulation and disposalIFC §304
Hazardous Material Quantities
- Hazard inventory
- Identify material, hazard class, quantity
- Safety data sheet
- Confirm hazards and incompatibilitiesIFC §407
- Maximum allowable quantity
- Compare by hazard and conditionIFC §5003.1.1
- Control area
- Protected area with quantity limits
- Physical versus health hazards
- Use applicable hazard tables
- Quantity columns
- Storage, closed use, open use
- Quantity adjustments
- Read qualifying footnotes and exceptions
- Above applicable limits
- Evaluate Group H and exceptionsIBC §307
- Incompatible materials
- Check required separationIFC §5003
Finishes and Fire Growth
- Wall and ceiling finish
- Check occupancy and finish locationIFC §803
- Finish documentation
- Verify applicable test classification
- Flame spread index
- Relative surface flame propagation
- Smoke-developed index
- Relative smoke generation in test
- Floor finishes
- Check separate finish criteriaIFC §804
- Decorations
- Check material and placement rulesIFC §§806–807
- Fire growth potential
- Assess fuel load and arrangement
- Blocked protection
- Check storage against required clearances
Common Traps
Passing score
75 scaled ≠ 75 percent correct
Inspection history
Complaint allegation ≠ Observed violation
System condition
Installed equipment ≠ Operationally ready equipment
Water supply
Static pressure before flow ≠ Residual pressure under flow
Occupancy assignment
Tenant business name ≠ Actual use of space
Fixed seats
Installed seat count ≠ Loose seating area factor
Hazard quantities
Control area quantity ≠ Building-wide inventory total
Material performance
Finish flame spread index ≠ Assembly fire-resistance rating
Last Minute
- 1.Match books to registered edition
- 2.Leave study sheets outside exam
- 3.Use adopted code in field
- 4.Record observation, location, code citation
- 5.Trace access, exit, discharge
- 6.Verify routes remain unobstructed
- 7.Compare installed systems with approved plans
- 8.Check maintenance and impairment records
- 9.Check plan triggers and drill logs
- 10.Classify actual building use
- 11.Match load factor to function
- 12.Check storage, open-use, closed-use limits