6.7 Construction Trades and Specialties: Plumbing, Plastics, Doors and Windows, Finishes, and Electrical

Key Takeaways

  • Every plumbing fixture needs a trap with a water seal, and a vent system that keeps the seal from being siphoned.

  • CPVC and PPR pipes are rated for hot water, while ordinary uPVC is used for cold water and drainage.

  • Tempered glass breaks into small blunt pieces, while laminated glass is held together by its interlayer when broken.

  • Paint systems are applied as surface preparation, primer, intermediate coats and finish, each compatible with the substrate.

  • Branch-circuit conductors are sized for at least 125% of continuous load and protected by a circuit breaker matched to the conductor ampacity.

Last updated: October 2026

6.7 Construction Trades and Specialties: Plumbing, Plastics, Doors and Windows, Finishes, and Electrical

The AMSTHC TOS area "Construction Trades and Specialties" has five one-item competencies:

  1. Recall basic plumbing design, construction and installation.
  2. Classify and determine plastics for construction.
  3. Select details of doors and windows for proper application.
  4. Identify and select finishing materials.
  5. Understand basic electrical design, construction and installation.

Civil engineers coordinate these trades and are expected to know their vocabulary and basic rules. The governing codes are:

  • the National Plumbing Code of the Philippines, under the Plumbing Law (RA 1378);
  • the Philippine Electrical Code (PEC Part 1, under the Electrical Engineering Law, RA 7920);
  • the Fire Code (RA 9514) for fire-rated doors.

Plumbing Basics

SystemComponentsKey rules
Water supplyService connection, water meter, gate valves, risers, branches, storage tank, booster pumpSize pipes for peak demand and residual pressure; prevent backflow with air gaps or check valves
Drainage (sanitary)Fixture drains, traps, branch drains, soil and waste stacks, building drain and sewerGrade horizontal drains at about 2% (1:50) for small pipes; provide cleanouts at changes of direction
VentingVent pipes from fixture traps to the vent stack and roofKeeps air pressure balanced so trap seals are not siphoned or blown out
Storm drainageGutters, downspouts, catch basinsKept separate from sanitary drainage
Private disposalSeptic tank with leaching fieldSized for population; two compartments; watertight

Traps. A P-trap holds a water seal, typically about 50 to 100 mm deep, that blocks sewer gas. Seal loss is caused by siphonage (inadequate venting), evaporation (unused fixtures) and back-pressure.

Drainage fixture units express the relative discharge load of fixtures; pipe sizes are chosen from code tables based on total fixture units.

Common pipe materials:

  • uPVC for cold water, drainage and vents;
  • CPVC or PPR for hot water;
  • galvanized iron (older systems);
  • copper;
  • HDPE for service lines and underground mains.

Plastics in Construction

PlasticMain usesNotes
PVC / uPVC (polyvinyl chloride)Cold water and drainage pipes, electrical conduit, window framesRigid; joined by solvent cement; not for hot water
CPVC (chlorinated PVC)Hot and cold water pipesHigher temperature rating than PVC
PPR (polypropylene random copolymer)Hot and cold waterJoined by heat fusion, giving leak-free joints
PE / HDPE (polyethylene)Water mains, gas lines, geomembranes, vapor barriersFlexible and tough; butt- or electro-fusion joints
PolycarbonateSkylights, roofing sheetsHigh impact strength; needs UV protection
Acrylic (PMMA)Glazing, signageClear, but scratches more easily
Fiber-reinforced plastic (FRP)Tanks, gratings, strengthening wraps for concreteHigh strength-to-weight ratio; corrosion resistant
Expanded and extruded polystyreneInsulation, lightweight fillCombustible; must be protected

Thermoplastics (PVC, PE, PP) soften when heated and can be reshaped or welded. Thermosets (epoxy, polyester, phenolic) cure permanently. Plastics expand far more with temperature than steel, so long runs need expansion allowances. Many degrade in sunlight unless UV-stabilized.


Doors and Windows

Door parts:

  • the frame or jamb (head and side jambs, with a threshold at the floor);
  • the leaf or shutter;
  • the stop;
  • the hardware: hinges, lockset, closer, panic bar.

Window parts:

  • the frame (head, jambs, sill);
  • the sash;
  • mullions (vertical dividers) and transoms (horizontal dividers);
  • glazing.
TypeTypical application
Swing (hinged) doorRooms, exits; exit doors swing in the direction of travel
Sliding door or windowLimited swing space
Folding or accordion doorWide openings
Casement window (side-hinged)Good ventilation, tight seal
Awning (top-hinged) or jalousie windowVentilation in rain; jalousies are common in tropical houses
Fire door (labeled, self-closing)Exit stairs, rated walls under the Fire Code

Glazing options:

  • Annealed float glass is the basic type and breaks into sharp shards.
  • Tempered glass is about four to five times stronger and breaks into small blunt pieces. It is required in hazardous locations such as doors and low panels.
  • Laminated glass keeps its interlayer intact when broken; it is used in overhead and security glazing.
  • Insulating glass units improve thermal performance.

Aluminum and uPVC frames resist rot. Wood needs treatment and finishing. All windows need proper sill slope and flashing to shed water.


Finishing Materials

ElementCommon materialsSelection points
WallsCement plaster with paint; ceramic tiles; stone; wall panelsMoisture exposure, cleanability, impact
FloorsCeramic or porcelain tiles, granite, terrazzo, vinyl, epoxy, polished concrete, woodAbrasion, slip resistance (wet areas), loads, maintenance
CeilingsGypsum board, fiber-cement board, acoustic tiles on metal gridFire rating, humidity, acoustics
RoofingPre-painted metal sheets, tiles, waterproofing membranes for flat roofsSlope, wind uplift, corrosion
WaterproofingCementitious coatings, bituminous or liquid membranesToilets, roof decks, basements, water tanks

Paint systems follow a sequence: surface preparation (clean and repair; let new concrete or plaster cure and dry), primer or sealer, putty or skim coat where needed, then two or more finish coats. Alkali-resistant primers are used on new masonry. Epoxy or polyurethane systems are used for chemical or heavy-wear areas.


Basic Electrical Design and Installation

The Philippine Electrical Code (PEC Part 1) governs building wiring. Houses are typically served at a nominal 220–230 V single-phase, and larger buildings by three-phase services.

ConceptRule of practice
PowerP=VIcos⁡ϕP = VI\cos\phi for single-phase loads (cos⁡ϕ\cos\phi is the power factor)
Branch circuitsSeparate circuits for lighting, convenience outlets and large appliances (air conditioners, water heaters)
Conductor sizingAmpacity at least the load current, and at least 125% of continuous loads
Overcurrent protectionCircuit breaker rating not exceeding the conductor ampacity
Voltage dropCommonly limited to about 3% in a branch circuit and 5% overall
Grounding and bondingEquipment grounding conductor to every outlet and metal enclosure
RacewaysRigid steel, intermediate metal, EMT, or PVC conduit with boxes and fittings

Example. A 2.0 kW2.0\text{ kW} air conditioner on 230 V230\text{ V} with power factor 0.850.85 draws I=2,000/(230×0.85)=10.2 AI = 2{,}000/(230 \times 0.85) = 10.2\text{ A}. Treated as a continuous load, the circuit needs 1.25(10.2)=12.8 A1.25(10.2) = 12.8\text{ A} of conductor capacity. The conductor size and breaker rating are then selected from the PEC ampacity tables for the insulation type and installation method.

Loading diagram...
Drainage, Waste and Vent System
Test Your Knowledge

Why is a vent connected to the drainage pipe downstream of each plumbing fixture trap?

A

To replace the need for a trap

B

To let rainwater enter the sanitary system

C

To keep air pressure balanced so the trap's water seal is not siphoned or blown out

D

To increase water pressure at the fixture

Test Your Knowledge

Which glass should be specified for a full-height glass door because it breaks into small, relatively harmless pieces?

A

Tempered glass

B

Wired annealed glass

C

Tinted float glass

D

Annealed float glass

Test Your Knowledge

A 230-V single-phase water heater draws 18 A continuously. What minimum conductor capacity is required for the branch circuit?

A

20.7 A

B

18.0 A

C

22.5 A

D

36.0 A