5.2 Subjective Refraction: Fogging, Sphere Refinement & Duochrome Endpoint
Key Takeaways
Maximum plus to maximum visual acuity (MPMVA) means the most plus, or least minus, that preserves the best repeatable acuity with the other lens settings fixed.
Adding plus moves the focal plane forward for a fixed accommodative state. Use observed blur to establish fog, then remove it in small steps. Acuity change per step varies.
Green focuses anterior to red. With reproducible duochrome judgments, red sharper suggests a trial of minus and green sharper suggests a trial of plus.
Duochrome is a check on the sphere. Confirm the result on a white-background acuity chart and investigate unexplained reduced acuity.
Distance sphere and the fogging endpoint
Start monocularly with the net objective result or a verified starting prescription, using a calibrated distance target. Maximum plus to maximum visual acuity (MPMVA) means the most plus (least minus) sphere that preserves the patient's best repeatable acuity. Keep the cylinder fixed when comparing sphere. Ask the patient to read letters or identify details that are genuinely easier to resolve. Darker-looking letters alone are insufficient reason to add minus.
At a fixed accommodative state, extra plus increases converging power and moves the retinal image plane forward. If the initial distance image was focused on the retina, plus creates myopic defocus. Accommodation would move that image still farther forward. This gives the patient a reason to relax accommodation. The response varies with the person and amount of fog. Some people accommodate through part of the initial plus, and fogging does not guarantee full relaxation. Extra minus moves the image plane backward when accommodation is fixed. A young patient can sometimes counter the added minus by accommodating and keep reading at the same acuity.
- Record the chart setting, monocular acuity and starting lens. Use a suitable line for the patient's functional acuity. The target distance is the optical viewing distance, including the path of a mirror system if used. Light from a direct 6 m target has incident vergence of about at the eye in air, using the usual negative sign for a diverging bundle. This is distinct from a separate retinoscopy working-distance subtraction, which was already applied to obtain the objective starting point.
- Add plus sphere to produce mild, reproducible blur. One clinical protocol begins with and adds more if there is little change. Failure to fog on the first step merits a check of fixation, starting correction and response. This finding alone cannot diagnose latent hyperopia.
- Reduce plus in steps and remeasure acuity. As one practical cue, improvement should become evident when effective defocus is reduced. The number of letters or lines gained is variable.
- Stop at the first sphere giving the best repeatable acuity. If another quarter diopter of minus adds no resolved detail, return to the more positive setting. Recheck sphere after meaningful cylinder refinement.
Worked example. With a starting sphere of , adding sets the dial to . The patient has measurable blur. The examiner then tests , , , , and . Acuity reaches at . At the patient can read the same letters and reports only a darker appearance. The working endpoint is . This example describes observed acuities for one patient. A given diopter of fog has no fixed Snellen equivalent.
Duochrome as a check on sphere
The eye shows longitudinal chromatic aberration. Ocular media typically refract the shorter green wavelengths more strongly than the longer red wavelengths. At a fixed lens setting, the green focal plane is anterior and the red focal plane is posterior. The exact separation depends on the display spectra, the eye and how focus is measured. Clinical defocus curves need not show the full separation predicted by a simple optical model.
Use black letters on the two backgrounds close to the best sphere. Ask which panel's letters look better defined or blacker, avoiding judgments about the brighter background or the name of the color. Confirm a reproducible preference before changing the sphere.
| Repeatable report | Optical interpretation in the model | Trial change |
|---|---|---|
| Red letters sharper | Red focus lies closer to the retina, with the pair tending anterior | Red add minus. Try sphere. |
| Green letters sharper | Green focus lies closer to the retina, with the pair tending posterior | Green add plus. Try sphere. |
| Both similar | Their perceived defocus is approximately balanced | Return to white-background acuity and check the most plus for best acuity. |
Worked example. At the green panel is consistently sharper. Add to test . If the panels are then similar and the same best acuity is maintained in white light, is supported. If the preference reverses across one quarter diopter, bracket the response and prioritize the white-background endpoint. Duochrome does not establish a sphere to within a fixed tolerance.
A patient can identify panels by position. Color naming is unnecessary, but contrast, screen luminance, media opacity or unstable responses can limit interpretation. Use other endpoint checks when the patient cannot reliably compare the letters. Some experiments have found age-group differences in chromatic acuity, which do not justify a fixed sphere correction for older adults.
Pinhole and reduced acuity
If acuity is unexpectedly low, test the pinhole as one part of an assessment. A small aperture limits the range of rays entering the eye and may reduce optical defocus blur. Improvement supports rechecking sphere, cylinder, and optical quality. The amount of improvement alone does not identify its cause or exclude coexisting disease. Lack of improvement can reflect optical problems, reduced illumination or eye disease. Assess the history and other findings and arrange referral for unexplained loss or suspected pathology when the necessary evaluation is outside the facility's scope.
Sources
- University of Iowa clinician refraction protocol, MPMVA and duochrome
- Objective measurements of individual responses to fogging
- Comparison of fogging and cycloplegia in young adults
- Thibos and colleagues, measured chromatic difference of focus
- Age-group study of red and green defocus curves and duochrome
- Clinical comparison of duochrome before and after correcting cylinder
- Clinical comparison of pinhole and manifest visual acuity
- DHA optical-center standards, sections 7–9
Sources checked November 25, 2026.
During subjective de-fogging, a 19-year-old patient reads 6/6 (20/20) with -1.50 DS. When the examiner tests -1.75 DS, the patient still reads the exact same 6/6 line but says the letters look "darker and crisper." According to MPMVA principles, what should the examiner do?
Prescribe -1.75 DS because the patient prefers the crisper contrast
Increase fogging to +3.00 D and repeat retinoscopy
Keep −1.50 DS as the sphere endpoint for this step
Add -0.50 DS more to verify if 6/5 is achievable
On the Duochrome test, why does green light focus anterior to red light inside the human eye?
Shorter-wavelength green light experiences a higher ocular refractive index and bends more strongly than longer-wavelength red light
Longer-wavelength red light is absorbed by the crystalline lens before reaching the macula
Green light stimulates M-cones located anterior to L-cones in the outer nuclear layer
Red light undergoes greater diffraction at the pupillary margin, shortening its focal length
A patient with red–green color deficiency gives repeatable judgments by panel position. At −2.00 DS, the letters on the green panel look sharper. What trial sphere is appropriate before rechecking white-background acuity?
−2.25 DS, to increase minus and bring the green image forward
−2.50 DS, to move both focal planes forward
−2.00 DS, because the patient must be able to name both colors
−1.75 DS, by adding +0.25 D to the current setting
At the provisional distance endpoint, right-eye acuity is 6/12 (20/40). With a pinhole over the trial lenses, it improves to 6/6 (20/20). Which conclusion is best supported?
Dense macular degeneration limiting photoreceptor density
Residual optical blur may be contributing, so recheck the refraction and optical quality
Strabismic amblyopia unresponsive to optical correction
Optic nerve atrophy preventing central fixation
Sections you finish are checked off in the contents.