12.1 Low Vision Assessment, M-Notation, Contrast & Functional Goals

Key Takeaways

  • WHO distance impairment categories commonly use presenting acuity in the better eye for population reporting. Rehabilitation needs also depend on tasks, fields, contrast and the person's goals.

  • Record the actual distance and chart calibration when shortening an acuity test. Scale numerator and denominator by the same factor to express an equivalent fraction.

  • A 1 M optotype is about 1.45 mm high and subtends five arcminutes at one meter. At 40 cm, 2 M corresponds to decimal acuity 0.20, or 6/30.

  • Measure contrast separately when high-contrast acuity fails to explain a task difficulty. Record chart, distance and conditions.

  • Reading threshold, critical print size and maximum reading speed measure different aspects of reading. Trial enough reserve and verify with the actual task.

Last updated: November 2026

Establish the Rehabilitation Goal

Vision rehabilitation helps people manage activities that remain difficult after appropriate optical and medical care. Begin by asking which task matters and what makes it difficult. One patient wants to distinguish medication containers. Another needs to locate a transit sign or see steps in dim light. Measure the real print, distance and contrast where possible. Ask about glare, preferred lighting, field loss, dexterity, previous devices and willingness to use them.

New unexplained visual loss or suspected active disease needs ophthalmology assessment. Describe the onset and severity to determine urgency. Rehabilitation can be planned alongside medical care. DHA ST-60 prohibits tonometry, OCT and fundus-camera equipment in standalone optical centers; refer when the necessary investigation is outside the service.

Record Impairment in the Right Context

WHO reporting uses presenting distance acuity in the better eye, measured with habitual distance correction if worn. These distance bands are useful for describing impairment.

WHO distance categoryPresenting acuity in better eye
Mild impairmentWorse than 6/12 through 6/18 inclusive
Moderate impairmentWorse than 6/18 through 6/60 inclusive
Severe impairmentWorse than 6/60 through 3/60 inclusive
Blindness by the acuity criterionWorse than 3/60

A person can benefit from rehabilitation without reaching a blindness threshold. Record fields and other functional findings separately. U.S. statutory blindness rules have their own correction and field criteria. In the UAE, the Ministry of Family's People of Determination Card process requires documentation from an accredited official authority. A calculated acuity equivalence in the optical center does not establish eligibility.

Measure Distance Acuity at an Appropriate Distance

If the patient cannot read the largest line at the standard distance, use a calibrated low-vision chart or shorten the distance according to the test protocol. An ETDRS chart can be used at a defined shorter distance under its protocol. A Feinbloom-style number chart is another option. Check its labeling before converting the result. A trial frame can leave room for a preferred head posture or small working distance. Record the test distance, chart and optical correction. Use an appropriate standardized lower-level method if conventional optotypes cannot be resolved.

If the physical optotype is labeled for a denominator LL and the test distance is dd, record d/Ld/L using the same distance unit for both. The denominator of the equivalent 6 m fraction is 6L/d6L/d when both distances are in meters.

Actual resultScaleEquivalent fraction
5/2005/200 on a chart labeled in feet20/5=420/5=420/80020/800, equivalent to 6/2406/240
1/601/60 on a metric chart6/1=66/1=66/3606/360
2/202/20 on a metric chart6/2=36/2=36/606/60

If you are using the printed 4 m logMAR value for the same optotype, add log⁡10(4/d)\log_{10}(4/d) when it is read from dd meters. This is approximately +0.30 at 2 m and +0.60 at 1 m. Follow the protocol for letter-by-letter scoring, particularly when screens or charts already adjust for distance.

Convert Near Acuity in M Notation

A 1 M optotype subtends five arcminutes at one meter, a height of about 1.45 mm. An M value describes a physical print size, so record the viewing distance as well. For words in mixed-case reading charts, use the chart's documented calibration.

At 40 cm, a threshold of 2 M gives decimal acuity 0.40/2.00=0.200.40/2.00=0.20. The 6 m equivalent has a denominator of 6/0.20=306/0.20=30, giving 6/30 or 20/100. At 20 cm, a threshold of 1 M gives the same calculated angular acuity because 0.20/1.00=0.200.20/1.00=0.20. Relative-distance magnification can make smaller print visible if the patient has sufficient optical focus and tolerates the shorter working distance.

Suppose the threshold is 2 M at 40 cm and the patient's label is 0.8 M. The threshold size ratio is 2/0.8=2.52/0.8=2.5. If you choose to try a twofold reading reserve, the effective target is 4 M and the starting magnification at the same distance is 4/0.8=54/0.8=5. Verify with real print and the patient's viewing distance. A reserve calculation is a trial estimate.

Measure Contrast and Reading Performance

High-contrast acuity may leave poor performance with gray print, faces or steps unexplained. The Pelli–Robson chart uses constant-size letters with decreasing contrast in triplets, usually at 1 m according to its instructions. The contrast changes by 0.15 log unit between triplets. Record the score, distance and test conditions. Lower log contrast sensitivity means the person needs higher target contrast. Interpret it with the actual task and the eye examination.

The MNREAD chart uses continuous text. Reading acuity is the smallest print that can be read, maximum reading speed is the plateau reached when size no longer limits performance, and critical print size is the smallest print that supports that speed by the chosen scoring method. Use lighting, actual reading material and the planned device to confirm that the patient can read comfortably. A chosen starting reserve can guide the trial, and print size can be adjusted based on measured performance.

Loading diagram...
Assess Function and Test a Low Vision Goal
Test Your Knowledge

A patient reads the 60 m optotype at a test distance of 1.5 m. What is the equivalent 6 m Snellen fraction?

A

6/120

B

6/240

C

6/360

D

6/60

Test Your Knowledge

For WHO population reporting, the better eye's distance acuity with habitual correction is exactly 6/60. Which acuity category applies?

A

Mild distance impairment

B

Severe distance impairment

C

Blindness by acuity

D

Moderate distance impairment

Test Your Knowledge

At 40 cm a patient reads 2 M at threshold. Which is the Snellen equivalent and effective print size for a twofold reserve trial at the same distance?

A

6/30 and 4 M

B

6/15 and 1 M

C

6/60 and 0.8 M

D

6/12 and 2 M

Test Your Knowledge

An older patient reads high-contrast letters at 6/18 but struggles with gray print and dimly lit steps. Which measurement most directly tests the ability to identify lower-contrast targets?

A

Repeat the same high-contrast chart

B

Record the number of lines missed on an Amsler grid

C

Measure letter contrast sensitivity with a Pelli–Robson chart and record its conditions

D

Measure color discrimination with Ishihara plates

Sections you finish are checked off in the contents.