6.3 Sensory Adaptation: Suppression, ARC, Stereopsis & Sensory Testing
Key Takeaways
The horopter describes points of corresponding visual direction. Panum’s fusional limits allow some disparity with single vision and vary with the stimulus.
Visual confusion involves different objects with a shared perceived direction. Diplopia involves one object perceived in two directions.
An intact Bagolini cross centered on one light while a manifest deviation persists supports harmonious anomalous retinal correspondence under those conditions.
Worth four-dot responses depend on filter eye, dot separation and viewing distance. Distance suppression with near peripheral fusion can support monofixation.
Eccentric fixation is demonstrated monocularly. Stereo tests differ by stimulus and edition, and some contour items permit nonstereo identification.
Correspondence, disparity, and single vision
Retinal points with the same subjective visual direction are corresponding points. The horopter describes locations in space that stimulate corresponding points for a particular fixation. The Vieth–Müller circle is a geometric model of the horizontal horopter. The measured horopter depends on the eyes and the stimulus.
Within Panum's fusional limits, the two eyes can receive slightly disparate images and still perceive one object. Horizontal disparity in this range can support stereoscopic depth. The limits depend on eccentricity, contour and presentation. For example, fine central lines have smaller limits than those found with blurred contours in experimental measurements. Outside the limits, a near object relative to a more distant fixation can give crossed physiological diplopia. An object sufficiently beyond fixation can give uncrossed diplopia.
When ocular alignment changes, one object may fall on points with different subjective visual directions. This is diplopia. With normal correspondence, esotropia typically gives uncrossed separation and exotropia crossed separation. Visual confusion refers to two different objects seen in a shared apparent direction. A person can suppress, fuse, or report diplopia depending on the viewing conditions and sensory status. There is no single age at which suppression becomes impossible.
Suppression, anomalous correspondence, and fixation
Suppression is reduced perception of input from one eye during binocular viewing. It can affect a region of the field and vary with fixation and stimulus conditions. In early-onset strabismus, fixation preference and chronic interocular imbalance may be associated with amblyopia. Suppression during binocular testing and reduced monocular best-corrected acuity describe different findings.
With anomalous retinal correspondence (ARC), the fovea of a fixating eye and a nonfoveal point in its fellow can share a visual direction despite a motor deviation. Compare the measured alignment with the separation or alignment the patient reports under comparable conditions. Using a consistent direction convention, the angle of anomaly is objective angle minus subjective angle. If the measured angle is and the subjective separation expressed in the same convention is , the difference is . Harmonious ARC describes a subjective angle near zero while the motor deviation is present. In normal correspondence the subjective and objective angles are expected to agree when tested comparably. The result can change with the degree of sensory dissociation.
Eccentric fixation means the eye uses a nonfoveal locus to fixate while viewing on its own. It can be assessed with a fixation target and fundus-referenced examination. ARC describes an interocular spatial relationship assessed during binocular testing. Eccentric fixation and ARC can coexist.
Sensory tests and expected responses
Record which eye sees which target, the alignment under those conditions, and the test distance. Confirm that monocularly each eye can see its stimulus before interpreting a binocular absence.
| Test | What to compare | Response and interpretation |
|---|---|---|
| Bagolini striated lenses | Each lens makes a different diagonal streak from the same point light. The lenses minimally disrupt viewing. | Two complete streaks meeting at the light show simultaneous input in one perceived direction. If a definite tropia persists during the task, the response supports harmonious ARC. A missing streak or central gap supports suppression of all or part of that eye's stimulus. Separated streaks can indicate diplopia. |
| Worth four-dot, red OD and green OS | The eye behind red can see two lights and the eye behind green can see three. The common white target can take on red, green or mixed color. | Seeing four lights indicates combined input under these conditions. Two red lights supports suppression of the green-filter eye (OS), and three green supports suppression of the red-filter eye (OD). Five lights indicates diplopia. Check the spatial relationship of the colors. |
| Red glass, red OD | Compare the perceived red and white images of one point light. | If both are seen, red to the right is an uncrossed pattern, red to the left a crossed pattern. Red below white is consistent with a right hyperdeviation with normal projection. Interpret with the motor exam. |
| Bielschowsky afterimage test | The two foveas receive different line afterimages under controlled monocular fixation, and the relative directions of the afterimages are reported. | A centered cross supports normal foveal correspondence in this dissociated test. Displacement can suggest altered correspondence if both stimuli were centered. Check fixation before interpreting it. |
Worked example. Red is over OD and green over OS. With a small angular dot separation at distance, a patient reports only two red dots. With a larger angular separation at near, the same patient sees four. This supports central suppression OS with peripheral fusion in the near condition. It does not establish the size of the suppression zone without measuring the angular dot spacing. A change in working distance may also alter alignment or accommodation. Compare with cover testing, fixation and stereoacuity.
Stereopsis and the limitations of individual tests
Stereoacuity is recorded in seconds of arc. A lower disparity threshold represents finer performance on the same test. Record the test name or edition, viewing distance, correction and threshold. One numeric threshold does not determine whether every binocular function is normal.
| Test example | Stimulus and interpretation |
|---|---|
| Original Stereo Fly (Titmus-type contour test) | The SO001 graded circle series ranges from 800 to 40 arcseconds. Early coarse contour items may contain monocular clues such as lateral displacement. |
| Randot SO002 | The random-dot shapes use 500 and 250 arcseconds. Its separate graded circle series spans 400 to 20 arcseconds. Distinguish which task the patient passed. |
| TNO | Red–green viewing separates random-dot stimuli. Record the booklet edition because results can differ between editions. |
| Lang I-R and II-R | Uses a lenticular surface and random dots without special glasses. Follow the instructions and distinguish the II-R two-dimensional control star from the stereoscopic targets. |
Random-dot testing reduces reliance on outlines visible to one eye. The strength of monocular clues depends on the test and presentation. A patient who passes coarse contour items but misses random-dot figures may be using those clues, may not understand the second task, or may have impaired binocular function. Check instructions, alignment and acuity before interpreting the discrepancy.
Sources
- Experimental effects of contour on Panum's fusional limits
- Bagolini's clinical study of suppression and anomalous correspondence
- Comparison of striated glasses and afterimage findings in strabismus
- Original measurements of eccentric monocular fixation in amblyopia
- Measured sensory suppression in alternating strabismus
- Worth four-dot dot spacing and suppression study
- University of Iowa clinical monofixation case
- University of Iowa red-filter and sensory-test teaching
- Validity study of contour circles against a random-dot test
- Stereo Optical SO001 and its graded circles
- Stereo Optical SO002 Randot specifications
- Clinical comparison of TNO editions
- Lang I-R and II-R manufacturer instructions
Sources checked November 25, 2026.
A child reports two complete Bagolini streaks crossing at a single light. The examiner confirms that a manifest left esotropia persists during that same viewing condition and that each line is seen monocularly. Which sensory interpretation is best supported?
Harmonious anomalous retinal correspondence
Normal retinal correspondence with pathological diplopia
Obligatory left-eye suppression
Unharmonious anomalous retinal correspondence
With red over OD and green over OS, a patient reports two red lights with a small angular dot pattern and four lights with a larger pattern. If alignment and visibility are otherwise comparable, which explanation is best supported?
Alternating suppression of the right eye at distance
Uncrossed physiological diplopia at near
A small central suppression scotoma in the left eye with peripheral fusion at near
Eccentric fixation in the right eye
A patient recognizes several coarse Titmus circle items but misses the Randot random-dot shapes. Which property of the Titmus items could allow this without demonstrating stereopsis?
Early Titmus circles test global rather than local stereopsis
Early Titmus circles contain monocular lateral-displacement clues
Randot shapes require 10 arcseconds of stereopsis
Titmus tests use red-green dissociation that breaks fusion
Which finding directly supports eccentric fixation rather than testing interocular correspondence?
Eccentric fixation occurs only under binocular viewing with Bagolini lenses
ARC persists when the fellow eye is covered during visuoscopy
Eccentric fixation causes crossed diplopia on the red filter test
A fundus-referenced exam shows the tested eye fixating with a nonfoveal locus while the fellow eye is covered
Sections you finish are checked off in the contents.