5.3 Astigmatism Assessment: Clock Dial, Stenopeic Slit & Jackson Cross-Cylinder
Key Takeaways
Regular astigmatism produces two perpendicular focal lines. The spherical equivalent is the mean of the two principal powers.
The fogged clock dial estimates a starting minus-cylinder axis from the sharpest spoke. Use the smaller clock number times 30° on the conventional dial.
A stenopeic slit reduces the aperture perpendicular to the slit and can help estimate orthogonal powers when high regular astigmatism makes comparisons difficult.
With the JCC handle on the trial axis, compare the two axis refinements. For power, align one marked cylinder axis with the trial axis and then flip.
To hold spherical equivalent constant while changing cylinder, adjust sphere by minus half the signed cylinder change, then recheck the sphere.
Sturm's conoid and spherical equivalent
In the simple regular astigmatic eye, the two principal power meridians are perpendicular. For a distant point object the stronger meridian brings its ray fan to focus sooner, leaving a focal line perpendicular to that stronger meridian. The weaker meridian produces a farther focal line at right angles to the first. The bundle between the two line foci is Sturm's conoid. The circular section between the line foci is the circle of least confusion in the ideal paraxial model, and its position lies halfway between the two foci in dioptric terms.
In a prescription with sphere and signed cylinder , the powers are along the cylinder axis and perpendicular to it. The arithmetic mean is the spherical equivalent:
For , the powers are at 180 and at 090, so the spherical equivalent is . A spherical lens can move the mean focus without correcting the difference between the meridians.
Fogged clock dial for a starting axis
A conventional astigmatic dial can supply a starting axis when an initial cylinder is uncertain. In the fogged-dial method, plus sphere brings both focal lines in front of the retina so the posterior line is nearer the retina. Start with enough fog to obtain the comparison specified for the chart. A fixed amount of sphere cannot guarantee sufficient fog in every eye, particularly with larger cylinder. Ask which pair of spokes looks darkest or best defined. If responses are inconsistent, use the objective estimate and another subjective check.
For a conventional clock dial and minus-cylinder notation, multiply the smaller clock number (1 to 6, using 6 for the vertical pair) by . The result is the correcting minus-cylinder axis, perpendicular to the sharpest spoke direction. For the 4–10 spoke, . Use the dial's actual markings for specialized charts.
| Darkest spoke pair | Starting minus cylinder axis |
|---|---|
| 1–7 | 030 |
| 2–8 | 060 |
| 3–9 | 090 |
| 4–10 | 120 |
| 5–11 | 150 |
| 6–12 | 180 |
Add minus cylinder in small steps while comparing the spokes. Equal appearance or reversal brackets the cylinder estimate. Remove the remaining fog and refine acuity using the sphere and cross-cylinder checks. The dial is an estimate for regular astigmatism.
Stenopeic slit for meridional comparisons
A stenopeic slit narrows the aperture in the direction perpendicular to its long axis. Rotating it changes which meridional blur is most restricted. When the slit is aligned with a principal meridian, a sphere refinement with that slit orientation estimates the power along it. This can help in high regular astigmatism when small cross-cylinder flips are hard to distinguish. In eyes with scarring or irregular optics, slit orientation can affect visual acuity, but two orthogonal numbers may not adequately describe the optical error. Examine the cause of the reduced acuity before assuming a spectacle cylinder will solve it.
Remove the tentative cylinder, rotate the slit for a reproducible meridional comparison and refine the sphere in that orientation. Repeat with the slit turned 90° in a regular astigmatic eye. For estimated powers of at 180 and at 090, the more positive meridian supplies sphere and axis. The difference is , giving . Confirm on an ordinary acuity target without the slit.
Jackson cross-cylinder (JCC)
A JCC has principal powers of and . This is equivalent to a sphere combined with a cylinder. Thus . The flip swaps the principal powers without changing their mean. In the usual handheld marking convention red identifies the minus-cylinder axis and white identifies the plus-cylinder axis. Verify the markings for the instrument being used. Here the trial prescription is in minus-cylinder notation.
- Axis comparison. Start from a usable sphere and estimated cylinder. Align the handle with the trial cylinder axis so the two JCC axes straddle it by 45°. Present the two flips on a readable letter or dot target. Rotate the trial minus-cylinder axis a small step toward the red mark in the clearer flip. Reposition the handle on the new axis and repeat. When preference reverses, use smaller steps to bracket equality.
- Power comparison. Orient one marked JCC axis on the trial axis, which puts the handle 45° away. If the red axis on the trial axis gives the clearer view, test more minus cylinder. If the white axis on the trial axis is clearer, test less minus cylinder. Select the lowest cylinder magnitude that preserves the best repeatable acuity.
- Recheck. For a clear initial cylinder, an axis-first sequence is useful. When little or no cylinder is indicated, a brief power search can precede axis refinement. Recheck both if the comparisons change and repeat the monocular sphere endpoint afterward.
When the trial cylinder changes, preserve mean power during the comparison with . For example, starting from , increase minus cylinder to and add sphere. The new trial lens is , with in both settings. A quarter-diopter change in cylinder shifts the mean by only . If the instrument cannot offset that exactly, use available steps and verify the sphere at the endpoint.
Sources
- American Academy of Ophthalmology optical diagram of Sturm's conoid
- NIDEK RT-6100 operator manual, astigmatic clock dial
- Analytical study of the stenopeic slit in astigmatic refraction
- University of Iowa clinician protocol, minus-cylinder JCC and sphere recheck
Sources checked November 25, 2026.
A fogged patient viewing an astigmatic clock dial reports that the lines running from 4 o'clock to 10 o'clock appear darkest and sharpest. Using the Rule of 30 in minus-cylinder notation, at what axis should the minus cylinder initially be placed?
120 degrees
030 degrees
060 degrees
150 degrees
During JCC power refinement, cylinder changes from −1.00 to −1.50 D in a trial prescription of −3.00 −1.00 × 180. What sphere change holds the spherical equivalent constant for the next comparison?
Add -0.25 D sphere (new Rx: -3.25 - 1.50 x 180)
Leave the sphere unchanged (new Rx: -3.00 - 1.50 x 180)
Add +0.25 D sphere (new Rx: -2.75 - 1.50 x 180)
Add +0.50 D sphere (new Rx: -2.50 - 1.50 x 180)
While refining cylinder axis with a JCC in minus-cylinder mode (handle aligned at 090 degrees), the patient reports that Flip 1 is clearer, when the JCC red dots sit at 045 degrees and the white dots sit at 135 degrees. How should the examiner adjust the trial cylinder axis?
Rotate the cylinder axis toward 135 degrees
Rotate the cylinder axis toward 045 degrees
Increase minus cylinder power by -0.25 D at 090 degrees
Keep the axis at 090 degrees and move directly to power testing
An eye has high regular astigmatism. The patient cannot separate the small JCC flip differences but can compare acuity through a narrow aperture at different orientations. Which technique estimates the two principal powers one at a time?
Duochrome red–green test
Turville infinity balance
Vertical prism dissociation
Rotate a stenopeic slit and refine sphere in each orthogonal orientation
Sections you finish are checked off in the contents.