3.1 Schematic Eyes, Visual Acuity Notation & Contrast Sensitivity
Key Takeaways
A single-surface reduced eye with a power and an image-space index of has an image focal distance of from the surface.
For a standard Sloan optotype at its reference distance, height subtends five arcminutes and critical detail one arcminute. A score gives decimal acuity 1.0 and logMAR 0.
On an Early Treatment Diabetic Retinopathy Study chart, a line changes by 0.10 logMAR. In letter-by-letter scoring, each correct letter accounts for 0.02 logMAR.
Pinhole improvement suggests an optical component to reduced acuity. A limited response calls for refraction and an ocular assessment in the clinical context.
Letter acuity and contrast sensitivity answer different questions. The Pelli–Robson chart changes letter contrast while holding letter size constant.
Schematic eyes and cardinal points
Schematic eyes model the eye's refracting surfaces so you can trace light and compare optical predictions with clinical findings. Gullstrand represented the cornea and the lens with multiple surfaces. His detailed lens model distinguished the outer cortex and the nucleus to explore accommodation. A reduced eye instead uses a single effective surface for first-order calculations. Choose one model before interpreting a distance or deciding which reference plane it uses.
For an emmetropic reduced model, take the object-space index as 1, the image-space index as and the effective power as . The spherical surface radius is . The front focal point is in front of the effective surface. The rear focal point is behind it. We place the model retina at the rear focal point. These are model distances from the effective surface. A detailed schematic eye has separate reference planes, and a patient's measured axial length is a separate quantity.
| Paired cardinal points | Meaning for clinical optics |
|---|---|
| Front and rear focal points | Light from the front focal point emerges parallel. Parallel incident light is brought to the rear focal point. |
| Principal points | Their planes set the references for effective focal lengths. Their transverse magnification between the planes is . |
| Nodal points | A paraxial ray directed at the front nodal point emerges from the rear nodal point at the same angle to the optical axis. The reduced single-surface model has one common nodal point at the center of curvature. |
For this reduced eye, the nodal point is behind the effective surface, leaving from the nodal point to the model retina. A small visual angle of therefore spans about on that model retina. Use the nodal distance for this calculation. The entrance pupil is the image of the physical iris opening viewed from in front of the eye through the cornea. It is a separate reference in spectacle magnification.
Far point versus retinal focus. The far point is the object-space point conjugate to the retina with accommodation relaxed. The uncorrected myopic eye has a finite far point in front of it and brings parallel incident rays to a focus anterior to the retina. For a distant object, a correctly powered minus lens supplies a virtual image at the relaxed eye's far point. The eye then focuses this diverging light onto the retina.
Visual Angles and Minimum Angle of Resolution
At the reference distance, a standard Sloan optotype fits inside a grid where the entire letter subtends () and each stroke width or gap subtends () at the standard reference distance.
The Minimum Angle of Resolution (MAR) is the angular subtense (in arcminutes) of the smallest resolvable critical detail (stroke width). Normal threshold visual acuity ( or ) corresponds to . At any test distance (in meters), the physical height of a optotype is:
For example, on a chart, a letter measures tall, whereas a letter measures tall. Under Dubai's optical-center standard ST-60, the exam chair is at least from the chart or placed according to the manufacturer's recommendation. Use a chart calibrated for the actual optical viewing distance. For example, a -equivalent letter on a chart designed for is about tall.
Visual Acuity Notation Systems
Use the recorded viewing distance when converting between these acuity notations:
- Snellen Fraction (): The numerator is the actual test distance (often six meters or twenty feet for a Snellen chart), and the denominator is the distance at which the letter's strokes subtend (total height ). Thus, () means the patient at resolves what a standard eye resolves at ().
- Decimal Acuity (): The numerical quotient , which equals . For , ; for , ; for , .
- LogMAR (Logarithm of the Minimum Angle of Resolution): Defined as . Designed for the Bailey-Lovie and Early Treatment Diabetic Retinopathy Study (ETDRS) charts, every row contains five letters with logarithmic size progression ( per line), representing per line and per letter. Notice the inverted clinical direction: smaller or negative LogMAR values indicate better acuity ().
- M-Notation (Sloan M-units): Used for near reading acuity. A letter subtends at ( high). Near acuity is recorded as ; reading print at () is written , yielding (equivalent to or ).
| Snellen (Metric) | Snellen (Imperial) | MAR (arcmin) | Decimal Acuity | LogMAR |
|---|---|---|---|---|
Worked Example: ETDRS Letter Scoring
A patient reads all 5 letters on the line () plus 3 letters on the line. Starting from and subtracting for each additional letter read yields:
Exam Trap: Adding instead of subtracting moves the score toward worse acuity (), a frequent calculation error when scoring ETDRS progression.
Interpreting pinhole acuity
A pinhole blocks peripheral rays and reduces the blur circle from imperfect focus, increasing depth of focus. An improvement suggests a refractive or other optical contribution. Measure and compare the results with refraction and the rest of the examination. The size of an improvement depends on the initial acuity, aperture, lighting, and chart. A result with little improvement can reflect an opacity, a retinal or optic nerve disorder, amblyopia, or difficulty with the test. Reduced retinal illumination or diffraction through a small aperture can also limit acuity. Record the test and the result so later measurements can be compared.
Contrast sensitivity and high-contrast acuity
Contrast sensitivity is the reciprocal of the smallest contrast a person can detect for the target and conditions used. If threshold contrast is 0.02, sensitivity is 50 and its base-10 logarithm is about 1.70. In standard photopic grating experiments sensitivity generally peaks at intermediate spatial frequencies and declines toward low and high frequencies. The location and height of the peak depend on viewing conditions and observer. A high-contrast acuity chart measures the smallest letters recognized and gives limited information about dim or low-contrast tasks.
The Pelli–Robson chart holds letter size constant and reduces contrast from one triplet to the next by about 0.15 log unit. Grating tests use repeating bright and dark bars and can measure thresholds at several spatial frequencies. One chart score describes performance under its specified test conditions. Use the test instructions for distance, illumination and scoring, and document which correction the patient wore.
Clinical scenario. A driver can read with correction but struggles to see low-contrast road signs in poor light. Measure contrast sensitivity under standardized conditions to characterize that complaint. An abnormal result warrants assessment in context. The contrast score alone cannot identify whether lens scatter, retinal disease, optic nerve disease, or another cause explains the symptoms.
Sources
- Gullstrand's original lecture on the lens and accommodation
- OpenStax University Physics, refraction and the eye
- DHA optical-center standard, section 6.2.2
- Ferris et al., original ETDRS chart design
- University of Iowa, visual acuity testing and M-notation
- Population study of pinhole and refractive error detection
- Campbell and Robson, contrast sensitivity measurements
- Pelli, Robson and Wilkins, original contrast chart design
Sources checked November 25, 2026.
An emmetropic reduced eye has a single surface with air in front and image-space index . Where is the rear focal point relative to that surface?
22.22 mm behind
16.67 mm behind
22.22 mm in front
5.56 mm behind
A patient correctly reads the entire 0.30 LogMAR row (5 letters) and 2 additional letters on the 0.20 LogMAR row of an ETDRS chart. What is the patient's LogMAR visual acuity score?
+0.34
+0.10
+0.26
+0.22
A driver sees 6/6 with correction yet struggles to distinguish pale signs from their background. Which test directly assesses the additional visual function in this complaint?
Pinhole acuity
Contrast sensitivity using decreasing letter contrast or gratings
Anterior focal point localization
A second Snellen reading with larger black letters
During a near vision assessment, a presbyopic patient holds Sloan continuous-text cards at 40 cm and resolves the 1.0 M print size. What is the patient's approximate Snellen-equivalent near visual acuity?
6/6 (20/20)
6/9 (20/30)
6/24 (20/80)
6/15 (20/50)
Sections you finish are checked off in the contents.