7.2 Soft Contact Lens Fitting, Toric Stabilization & Multifocal Designs

Key Takeaways

  • Dk is oxygen permeability of the material. Dk/t also depends on lens thickness at the location evaluated.

  • Assess a settled soft lens for centration, coverage, movement, push-up behavior and the response of the ocular surface.

  • Assess sagittal depth with the whole design in mind. Base curve and diameter labels alone cannot predict on-eye fit across products.

  • Use stable toric rotation and the product’s reference marks to compensate the trial axis. Refit or investigate changing rotation before ordering.

Last updated: November 2026

Material and oxygen transport

Water content helps explain oxygen transport in conventional hydrogels. For comparable conventional hydrogels, higher water content generally allows greater oxygen permeability. Silicone-containing pathways allow many silicone hydrogels to have higher permeability even at lower water content. Modulus describes stiffness. Modulus, wettability, deposition and comfort depend on the individual formulation and surface. Compare measured product properties and the on-eye result.

Dk describes oxygen permeability of the lens material. Dk/t is oxygen transmissibility through thickness tt. A value reported centrally for one labeled power does not describe the whole lens or all powers. As thickness increases, local transmissibility decreases for the same material. High plus designs can be thicker centrally and high minus designs thicker off center. Toric stabilization can also change the thickness profile. Use product specifications to identify the power and location represented.

Worked example. A soft lens has Dk=28×10−11Dk=28\times10^{-11} in permeability units and a central thickness of 0.08 mm=0.008 cm0.08\text{ mm}=0.008\text{ cm}. Its local transmissibility is

Dk/t=28×10−110.008=35×10−9.Dk/t=\frac{28\times10^{-11}}{0.008}=35\times10^{-9}.

The numerical result in units of 10−910^{-9} is 35. This approximates the lens's central optical-zone transmissibility and does not measure corneal oxygen consumption or microbial risk.

Fitting a soft trial lens

Choose the trial using the specific product's guide. Let it settle for the recommended interval, then evaluate the fit with blinking and gaze changes. A smaller base-curve radius increases depth for a spherical surface at a fixed chord, and a larger chord increases depth at a fixed radius. On an actual lens, the back-surface design, diameter, thickness, modulus and ocular shape all influence behavior. Comparing labeled base curves across products does not establish which lens will fit more tightly.

ObservationExample findingsNext check
Appropriate movement and coverageCornea stays covered, the lens recenters smoothly, and acuity is stableConfirm comfort, push-up response and ocular surface condition before over-refraction.
Relatively tight fitMinimal movement, substantial resistance to gentle push-up, slow recovery or edge indentationTrial a less deep or different design, then recheck coverage, movement and tissue response.
Relatively loose fitExcessive movement on blinks, repeated decentration or edge liftTrial a design with more stable fit and check the lens again on the eye.

A push-up test assesses how readily the lens displaces and recenters. Interpret it alongside normal blink movement, coverage and edge interaction. Blur that changes with a blink can reflect movement, rotation, tear quality or an optical error. Check the lens and tear surface before attributing blur to a fit category. Fit assessments depend on lens design and protocol. One universal movement or resistance threshold cannot determine acceptable fit.

Stabilizing and compensating a soft toric lens

Toric lenses use thickness patterns to control rotation. Prism-ballasted and other thickened designs distribute material differently. Some designs use thin superior and inferior zones or other stabilization zones that interact with the lids. The design name alone does not guarantee a specific rotation, vertical prism, or acuity outcome.

Identify the location and purpose of the orientation marks in the product guide. Different products place the marks in different positions. In a lens with an inferior mark that normally lies at six o'clock, viewed face-on by the examiner:

  • If the inferior mark settles to the examiner's left, the viewed rotation is clockwise. Add its magnitude to the target corneal cylinder axis.
  • If the mark settles to the examiner's right, the viewed rotation is counterclockwise. Subtract its magnitude from the target axis.

This is LARS (left add, right subtract). Use the examiner's left and right and the stated inferior-mark convention. Use the target corneal-plane axis, with principal-meridian conversion where indicated. Check that the rotation is reproducible after blinking. If rotation is variable, investigate fit or try another design before compensating it.

Worked examples. A target axis of 090° with a stable inferior mark 15° to the examiner's left gives an estimated order axis of 105°. A target of 010° with a stable inferior mark 20° to the right gives −10°, equivalent to 170° because cylinder axis repeats every 180°. Compare available axes and verify acuity and orientation on the eye. An exact calculated axis is a starting target for trial selection.

Presbyopic lens options

Many soft multifocals place distance and near powers within the pupil at the same time. Designs can be center near, center distance or use other radial distributions. Pupil size, lighting, centration and the power distribution influence the result. Test real reading and intermediate demands and distance clarity under relevant lighting.

Monovision typically uses one eye preferentially for distance and the fellow for near. Test eye preference and the intended powers in a binocular trial. Monovision and multifocal designs can differ in contrast, depth perception and visual symptoms. Check stereo performance and task-specific clarity before finalizing, especially where depth judgment is important.

Sources

Sources checked November 25, 2026.

Loading diagram...
Soft lens assessment and stable rotation
Test Your Knowledge

A silicone hydrogel contact lens has an oxygen permeability of Dk=90×10−11Dk = 90 \times 10^{-11} units and a center thickness of 0.09 mm0.09\text{ mm}. What is its central oxygen transmissibility (Dk/tDk/t) in standard 10−910^{-9} units?

A

1010

B

8181

C

100100

D

10001000

Test Your Knowledge

The settled soft trial lens shows little movement, high push-up resistance and edge indentation. Within a comparable design, which change is a reasonable next trial to reduce sagittal depth?

A

Flatten the base curve (larger radius in mm) or decrease the total diameter

B

Steepen the base curve (smaller radius in mm) or increase the total diameter

C

Increase the lens center thickness to raise sagittal rigidity

D

Switch to a higher water-content conventional hydrogel with the exact same base curve and diameter

Test Your Knowledge

The target corneal-plane cylinder axis is 015°. A diagnostic toric lens with an inferior orientation mark settles 20° to the examiner’s right of six o’clock. The offset is reproducible after blinks. What is the calculated compensated axis?

A

035∘035^\circ

B

155∘155^\circ

C

165∘165^\circ

D

175∘175^\circ

Test Your Knowledge

Which comparison accurately contrasts conventional hydrogels and silicone hydrogels regarding water content, oxygen permeability, and mechanical modulus?

A

Silicone hydrogels require higher water content to achieve high Dk and typically have a lower modulus than conventional hydrogels

B

Silicone-containing materials can provide high Dk at lower water content. Modulus and wetting vary by formulation.

C

Both materials rely exclusively on polymer siloxane chains for oxygen transport and exhibit identical surface wettability

D

Conventional hydrogels cannot attract protein deposits because their surfaces are hydrophobic

Sections you finish are checked off in the contents.