Key Facts: WV Electrician Exam

70%

Passing Score

103CSR5, section 8.1.1

50

Questions

WV State Fire Marshal 2026 update

NEC 2023

Code Edition

WV State Fire Marshal 2026 update

West Virginia’s Journeyman Electrician examination has 50 multiple-choice questions based on the 2023 NEC from January 1, 2026 (State Fire Marshal). The licensing rules require a passing score of 70%. Confirm your examination time and permitted materials on the official authorization.

Sample WV Electrician Practice Questions

Try these sample questions to review concepts for the WV Electrician exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 307+ question experience with AI tutoring.

1Which agency administers the Journeyman Electrician license in West Virginia?
A.WV Division of Labor
B.West Virginia Electrical Licensing Board
C.WV Office of the Fire Marshal
D.WV Department of Commerce
Explanation: The West Virginia Electrical Licensing Board administers the Journeyman Electrician license. This board oversees all electrical licensing in the state and works with PSI for exam administration.
2West Virginia has reciprocity agreements for journeyman electrician licenses with which states?
A.Virginia and Maryland
B.North Carolina, Ohio, and Tennessee
C.All bordering states
D.Pennsylvania and Kentucky only
Explanation: West Virginia has reciprocity agreements with North Carolina, Ohio, and Tennessee for journeyman electrician licenses. Licensed electricians from these states may qualify for WV licensure without retaking the full exam.
3What NEC edition does West Virginia currently base its Journeyman Electrician exam on?
A.NEC 2017
B.NEC 2020
C.NEC 2023
D.NEC 2026
Explanation: West Virginia currently bases its Journeyman Electrician exam on the NEC 2020 edition adopted by the WV Electrical Licensing Board.
4How many questions are on the West Virginia Journeyman Electrician exam, and what is the time limit?
A.60 questions, 3 hours
B.80 questions, 4 hours
C.100 questions, 5 hours
D.75 questions, 3.5 hours
Explanation: The West Virginia Journeyman Electrician exam consists of 80 questions with a 4-hour time limit. The exam is administered by PSI and requires a minimum score of 70% to pass.
5Per NEC 2020 Article 210.8(A), GFCI protection is required for 125-volt, 15- and 20-ampere receptacles in dwelling unit bathrooms. What is the trip threshold for a Class A GFCI?
A.4-6 milliamperes
B.10 milliamperes
C.15 milliamperes
D.30 milliamperes
Explanation: A Class A GFCI device trips at 4-6 milliamperes of ground-fault current. This low threshold provides effective protection against electric shock in wet locations like bathrooms per NEC Article 210.8(A).
6Per NEC 2020 Article 250.52(A)(1), a metal underground water pipe used as a grounding electrode must be in direct contact with the earth for at least:
A.5 feet
B.8 feet
C.10 feet
D.15 feet
Explanation: Per NEC 2020 Article 250.52(A)(1), a metal underground water pipe in direct contact with the earth for 10 feet or more qualifies as a grounding electrode. This ensures adequate ground contact for effective grounding.
7Per NEC 2020 Table 310.16, what is the ampacity of a 10 AWG copper conductor with THHN insulation at 30°C?
A.30 amperes
B.35 amperes
C.40 amperes
D.45 amperes
Explanation: Per NEC 2020 Table 310.16, a 10 AWG copper conductor with THHN insulation (90°C column) has an ampacity of 40 amperes at 30°C ambient temperature.
8Per NEC 2020 Article 430.52, what is the maximum dual-element time-delay fuse size for a single motor branch circuit, expressed as a percentage of motor FLC?
A.125%
B.150%
C.175%
D.250%
Explanation: Per NEC 2020 Table 430.52, the maximum rating for a dual-element time-delay fuse for a single motor is 175% of the motor full-load current. If this value does not correspond to a standard fuse size, the next higher standard size may be used.
9Per NEC 2020 Article 210.52(A), receptacles in habitable rooms of dwelling units must be spaced so no point along the floor line is more than how far from a receptacle?
A.4 feet
B.6 feet
C.8 feet
D.12 feet
Explanation: Per NEC 2020 Article 210.52(A)(1), receptacle outlets must be installed so that no point along the floor line in any wall space is more than 6 feet, measured horizontally, from a receptacle outlet.
10Per NEC 2020 Article 220.12, the general lighting load for a dwelling unit is calculated at:
A.2 VA per square foot
B.3 VA per square foot
C.3.5 VA per square foot
D.5 VA per square foot
Explanation: Per NEC 2020 Table 220.12, dwelling units use 3 volt-amperes per square foot for general lighting load calculations. This value is the starting point for both the standard and optional calculation methods.

About the WV Electrician Exam

The West Virginia State Fire Marshal administers the Journeyman Electrician examination. From January 1, 2026, it uses the 2023 edition of NFPA 70, National Electrical Code. The examination has 50 multiple-choice questions worth two points each, with calculations included in that format.

Exam sponsor: West Virginia State Fire Marshal — Regulatory and Licensing Division. The requirements and fees below concern the certification or admission exam, separate from our free practice resources.

Questions

50 questions

Time Limit

Confirm the allotted time on your exam authorization

Passing Score

70%

Exam / Certification Fees

Confirm the current application and licensing fees with the State Fire Marshal

Exam sponsor website

Fees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.

Our practice resources: topics covered

We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.

20%

NEC General & Theory

Electrical theory, NEC definitions, blueprint reading, and Article 100 fundamentals

20%

Branch Circuits & Overcurrent Protection

Circuit sizing, AFCI/GFCI requirements, conductor ampacity, and overcurrent devices

20%

Wiring Methods & Materials

Raceways, cable types, boxes, fittings, conduit fill, and installation requirements

20%

Grounding, Bonding & Services

Grounding electrode systems, bonding requirements, service entrance, and feeder sizing

20%

Motors, Special Occupancies & Calculations

Motor circuits, transformers, hazardous locations, healthcare, pools, and load calculations

Preparing for the WV Electrician Exam

What You Need to Know

  • Passing score: 70%
  • Exam length: 50 questions
  • Time limit: Confirm the allotted time on your exam authorization
  • Exam / certification fees: Confirm the current application and licensing fees with the State Fire Marshal Official sources

Using Our Practice Resources

  • Work through all 307 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

WV Electrician: Suggested Study Strategy

1Review NEC 2023 Article 250 for grounding and bonding requirements
2Practice dwelling unit load calculations using both standard and optional methods per Article 220
3Study conductor ampacity tables (310.16) including temperature correction and bundling factors
4Focus on AFCI and GFCI requirements in Articles 210.8 and 210.12 for both dwelling and commercial
5Review motor circuit requirements in Article 430 including overload and branch circuit protection

Frequently Asked Questions

Which states have reciprocity with West Virginia for electrician licenses?

West Virginia has reciprocity agreements with North Carolina, Ohio, and Tennessee. Licensed journeyman electricians from these states may qualify for WV licensure without retaking the full exam.

What NEC edition is the WV electrician exam based on?

From January 1, 2026, all West Virginia electrical examinations use the 2023 edition of NFPA 70, National Electrical Code, according to the State Fire Marshal’s 2026 update.

How do I schedule the WV electrician exam?

Apply through the West Virginia State Fire Marshal’s licensing portal and consult its published examination dates and locations. Follow the official exam authorization for your appointment and materials.

Is the WV electrician exam open book?

Confirm the permitted codebook, annotations and other materials on your State Fire Marshal examination authorization. The tested reference is the 2023 NEC from January 1, 2026.