Which agency administers the Journeyman Electrician license in Utah?

A
B
C
D
to track
2026 Statistics

Key Facts: UT Electrician Exam

70%

Passing Score

UT DOPL

80

Questions

PSI

4 hrs

Time Limit

PSI

NEC 2020

Code Edition

UT DOPL

Utah's Journeyman Electrician exam has a ~55% pass rate and requires 70% to pass. The exam was consolidated into a combined Theory & Code format in August 2025. It is based on the NEC 2020 edition and covers 80 questions in 4 hours. A bound copy of the NEC is permitted during the exam.

Sample UT Electrician Practice Questions

Try these sample questions to test your UT Electrician exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1Which agency administers the Journeyman Electrician license in Utah?
A.Utah Department of Commerce
B.Utah Division of Occupational and Professional Licensing (DOPL)
C.Utah Labor Commission
D.Utah Department of Public Safety
Explanation: The Utah Division of Occupational and Professional Licensing (DOPL) administers the Journeyman Electrician license. DOPL oversees licensing for many trades and professions in Utah, including electrical licensing.
2How many questions are on the Utah Journeyman Electrician exam?
A.60 questions
B.70 questions
C.80 questions
D.100 questions
Explanation: The Utah Journeyman Electrician exam consists of 80 questions. As of August 2025, the exam is a combined Theory and Code exam administered by PSI with a 4-hour time limit.
3What NEC edition does Utah currently base its Journeyman Electrician exam on?
A.NEC 2017
B.NEC 2020
C.NEC 2023
D.NEC 2026
Explanation: Utah currently bases its Journeyman Electrician exam on the NEC 2020 edition. Utah adopted the 2020 NEC for electrical installations and examinations through DOPL regulation.
4Per NEC 2020 Article 100, a device that establishes a connection between two or more conductors or between one or more conductors and a terminal is called a:
A.Fitting
B.Connector
C.Receptacle
D.Junction
Explanation: Per NEC 2020 Article 100, a connector is defined as a device that establishes a connection between two or more conductors or between one or more conductors and a terminal. This definition distinguishes connectors from fittings and other devices.
5According to NEC 2020 Article 210.12, where are AFCI protections required in dwelling units?
A.Only bedrooms
B.Kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas, and similar areas
C.All rooms including bathrooms and garages
D.Only living rooms and bedrooms
Explanation: NEC 2020 Article 210.12(A) requires AFCI protection in kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas, and similar rooms or areas in dwelling units. Bathrooms, garages, and unfinished basements are excluded.
6What is the minimum passing score required on the Utah Journeyman Electrician exam?
A.65%
B.70%
C.75%
D.80%
Explanation: The minimum passing score for the Utah Journeyman Electrician exam is 70%. This means candidates must answer at least 56 of the 80 questions correctly to pass.
7Per NEC 2020 Article 210.8(A), GFCI protection is required for 125-volt, 15- and 20-ampere receptacles installed in which of the following locations in a dwelling unit?
A.Bedrooms only
B.Bathrooms, garages, outdoors, crawl spaces, basements, kitchens, laundry areas, and boathouses
C.Only bathrooms and kitchens
D.All locations within a dwelling unit
Explanation: NEC 2020 Article 210.8(A) requires GFCI protection for 125-volt, 15- and 20-ampere receptacles in bathrooms, garages, accessory buildings, outdoors, crawl spaces, basements, kitchen countertop areas, areas within 6 feet of sinks, laundry areas, and boathouses.
8According to NEC 2020 Table 310.16, what is the ampacity of a 12 AWG copper conductor with THHN insulation at 30°C ambient temperature?
A.20 amperes
B.25 amperes
C.30 amperes
D.35 amperes
Explanation: Per NEC 2020 Table 310.16, a 12 AWG copper conductor with THHN insulation (90°C column) has an ampacity of 30 amperes at 30°C ambient temperature. However, when used with 60°C terminations, the allowable ampacity is limited to 25 amperes per 110.14(C).
9Per NEC 2020 Article 250.66, what is the minimum size copper grounding electrode conductor required for a 2/0 AWG copper service-entrance conductor?
A.4 AWG
B.6 AWG
C.2 AWG
D.1/0 AWG
Explanation: Per NEC 2020 Table 250.66, for a 2/0 AWG copper service-entrance conductor, the minimum grounding electrode conductor size is 4 AWG copper. This table correlates service conductor size to the required grounding electrode conductor.
10According to NEC 2020 Article 430.52, the maximum branch circuit short-circuit and ground-fault protective device for a single motor using an inverse time breaker is what percentage of the motor full-load current?
A.125%
B.150%
C.200%
D.250%
Explanation: Per NEC 2020 Table 430.52, the maximum rating of a branch circuit short-circuit and ground-fault protective device for a single motor using an inverse time circuit breaker is 250% of the motor full-load current. If this value does not correspond to a standard size, the next higher standard rating may be used.

About the UT Electrician Exam

The Utah Journeyman Electrician exam is a combined Theory and Code exam based on the NEC 2020, administered by PSI. As of August 2025, Utah consolidated its exam into a single 80-question, 4-hour test covering electrical theory, NEC code compliance, load calculations, and installation practices.

Questions

80 scored questions

Time Limit

4 hours

Passing Score

70%

Exam Fee

$55-$75 (Utah Division of Occupational and Professional Licensing (DOPL))

UT Electrician Exam Content Outline

20%

NEC General & Theory

Electrical theory, NEC definitions, blueprint reading, and Article 100 fundamentals

20%

Branch Circuits & Overcurrent Protection

Circuit sizing, AFCI/GFCI requirements, conductor ampacity, and overcurrent protection

20%

Wiring Methods & Materials

Raceways, cable types, boxes, fittings, conduit fill, and installation requirements

20%

Grounding, Bonding & Services

Grounding electrode systems, bonding requirements, service entrance, and feeder sizing

20%

Motors, Special Occupancies & Calculations

Motor circuits, transformers, hazardous locations, healthcare, pools, and load calculations

How to Pass the UT Electrician Exam

What You Need to Know

  • Passing score: 70%
  • Exam length: 80 questions
  • Time limit: 4 hours
  • Exam fee: $55-$75

Keys to Passing

  • Complete 500+ practice questions
  • Score 80%+ consistently before scheduling
  • Focus on highest-weighted sections
  • Use our AI tutor for tough concepts

UT Electrician Study Tips from Top Performers

1Master NEC 2020 Article 250 (Grounding and Bonding) — it is heavily tested on the Utah exam
2Practice dwelling unit load calculations per Article 220 using both standard and optional methods
3Study conductor ampacity tables (310.16) and temperature correction/adjustment factors
4Focus on AFCI and GFCI requirements in Articles 210.8 and 210.12 — these have expanded significantly
5Review motor circuit requirements in Article 430, including overload protection and branch circuit sizing

Frequently Asked Questions

What changed with the Utah electrician exam in August 2025?

As of August 2025, Utah DOPL consolidated the Journeyman Electrician exam into a single combined Theory and Code exam. Previously, the exam was split into separate portions. The combined exam is 80 questions with a 4-hour time limit.

What NEC edition is the Utah electrician exam based on?

The Utah Journeyman Electrician exam is based on the NEC 2020 edition. Utah adopted the 2020 NEC for electrical installations and examinations through DOPL regulation.

Is the Utah electrician exam open book?

Yes, candidates are typically permitted to bring a bound copy of the NEC 2020 to the exam. No loose papers, tabs that can be removed, or handwritten notes are allowed. Check with DOPL for current reference material policies.

How do I schedule the Utah Journeyman Electrician exam?

The exam is administered by PSI on behalf of Utah DOPL. You must first apply through DOPL and receive approval, then schedule your exam through PSI's online system. The exam fee ranges from $55 to $75.