PracticeBlogFlashcardsEspañol
All Practice Exams

100+ Free NE Journeyman Electrician Practice Questions

Pass your Nebraska Journeyman Electrician License Exam exam on the first try — instant access, no signup required.

✓ No registration✓ No credit card✓ No hidden fees✓ Start practicing immediately
~55% Pass Rate
100+ Questions
100% Free
1 / 100
Question 1
Score: 0/0

According to NEC Article 100, what is the definition of a "continuous load"?

A
B
C
D
to track
2026 Statistics

Key Facts: NE Journeyman Electrician Exam

70%

Passing Score

NE Electrical Division

80

Questions

PSI exam

4 hrs

Time Limit

PSI exam

Dec 31

Expiration

Even-numbered years

The Nebraska journeyman electrician exam requires 70% to pass on 80 NEC-based questions in 4 hours. Nebraska uses the NEC 2023 edition. All Nebraska electrical licenses expire on December 31 of even-numbered years regardless of when issued. The exam is open-book with a bound NEC copy allowed.

Sample NE Journeyman Electrician Practice Questions

Try these sample questions to test your NE Journeyman Electrician exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1According to NEC Article 100, what is the definition of a "continuous load"?
A.A load where the maximum current is expected to continue for 3 hours or more
B.A load that operates 24/7
C.A load that exceeds 80% of the circuit rating
D.Any load powered by a dedicated circuit
Explanation: NEC Article 100 defines a continuous load as one where the maximum current is expected to continue for 3 hours or more. This affects conductor and overcurrent device sizing. Nebraska electricians working under NE State Electrical Division must comply with NEC 2023 requirements.
2Per NEC Article 100, what does "listed" mean?
A.Equipment included in a list published by a qualified testing laboratory that evaluates products
B.Equipment approved by the local inspector
C.Equipment mentioned in the NEC articles
D.Equipment sold by licensed distributors
Explanation: NEC Article 100 defines "listed" as equipment included in a list published by an organization acceptable to the authority having jurisdiction that evaluates products. Nebraska electricians working under NE State Electrical Division must comply with NEC 2023 requirements.
3Per NEC 110.26(A)(1), what is the minimum working space depth in front of electrical equipment for Condition 1, 0-150V?
A.36 inches (3 feet)
B.30 inches
C.42 inches
D.48 inches
Explanation: NEC Table 110.26(A)(1) requires 36 inches minimum depth for Condition 1 at 0-150V to ground. Nebraska electricians working under NE State Electrical Division must comply with NEC 2023 requirements.
4Per NEC 110.14(C)(1), what temperature rating governs conductor terminations on equipment rated 100A or less?
A.60°C unless both the conductor and equipment are listed for a higher temperature
B.75°C is the standard for all terminations
C.90°C to maximize conductor ampacity
D.The conductor temperature rating always governs
Explanation: NEC 110.14(C)(1) requires using the 60°C ampacity column for circuits 100A or less, unless both the equipment and conductors are rated and listed for higher temperatures. Nebraska electricians working under NE State Electrical Division must comply with NEC 2023 requirements.
5Per NEC 110.12, what general requirement applies to all electrical equipment installation?
A.Equipment must be installed in a neat and workmanlike manner
B.Equipment must be painted to match the building
C.All wiring must be concealed
D.Equipment must be labeled with installer information
Explanation: NEC 110.12 requires electrical equipment to be installed in a neat and workmanlike manner. Inspectors use this as a general quality standard. Nebraska electricians working under NE State Electrical Division must comply with NEC 2023 requirements.
6Per NEC 110.3(B), what obligation exists regarding manufacturer instructions for listed equipment?
A.Listed equipment must be installed and used per its listing and any instructions included in the listing
B.Instructions are suggestions that can be disregarded
C.Only the NEC, not manufacturer instructions, must be followed
D.Instructions only apply during the warranty period
Explanation: NEC 110.3(B) mandates that listed or labeled equipment be installed and used in accordance with its listing instructions, making them enforceable code requirements. Nebraska electricians working under NE State Electrical Division must comply with NEC 2023 requirements.
7What is the minimum headroom required for working spaces around electrical equipment per NEC 110.26(A)(3)?
A.6 feet 6 inches or the height of the equipment, whichever is greater
B.6 feet
C.7 feet
D.8 feet
Explanation: NEC 110.26(A)(3) requires minimum headroom of 6.5 feet or the height of the equipment, whichever is greater. Nebraska electricians working under NE State Electrical Division must comply with NEC 2023 requirements.
8Per NEC 110.26(C)(2), when are two entrance doors required for an electrical room?
A.When equipment rated 1,200A or more and over 6 feet wide is installed
B.For any electrical room over 100 sq ft
C.When the room contains more than 3 panels
D.Two doors are never required
Explanation: NEC 110.26(C)(2) requires two entrance doors when equipment rated 1,200A or more is over 6 feet wide. Nebraska electricians working under NE State Electrical Division must comply with NEC 2023 requirements.
9Per NEC 210.8(A), GFCI protection is required for 125V, 15- and 20-ampere receptacles in which dwelling unit locations?
A.Bathrooms, kitchens, garages, outdoors, crawl spaces, basements, laundry areas, and within 6 feet of sinks
B.Only bathrooms and kitchens
C.Bathrooms, garages, and outdoors only
D.All rooms in the dwelling unit
Explanation: NEC 210.8(A) lists numerous locations requiring GFCI including bathrooms, garages, outdoors, crawl spaces, basements, kitchens, laundry areas, and within 6 feet of sinks. Nebraska electricians working under NE State Electrical Division must comply with NEC 2023 requirements.
10What is the maximum continuous load on a 20-ampere branch circuit per NEC 210.20(A)?
A.16 amperes (80% of 20A)
B.20 amperes
C.18 amperes
D.15 amperes
Explanation: NEC 210.20(A) requires the branch-circuit overcurrent device rating to be not less than 125% of the continuous load, so the maximum continuous load is 80% of 20A = 16A. Nebraska electricians working under NE State Electrical Division must comply with NEC 2023 requirements.

About the NE Journeyman Electrician Exam

Nebraska's journeyman electrician exam is administered by PSI on behalf of the State Electrical Division. The exam tests NEC 2023 knowledge including wiring methods, grounding and bonding, load calculations, motor circuits, and special occupancies. Nebraska licenses expire December 31 of even-numbered years.

Questions

80 scored questions

Time Limit

4 hours

Passing Score

70%

Exam Fee

$25-$125 (Nebraska State Electrical Division (PSI))

NE Journeyman Electrician Exam Content Outline

20%

NEC General & Definitions

NEC Article 100 definitions, general requirements, and code navigation

20%

Branch Circuits & Overcurrent Protection

Circuit sizing, conductor ampacity, GFCI/AFCI, and overcurrent devices

20%

Wiring Methods & Materials

Raceways, cable types, conduit fill, box fill, and installation methods

20%

Grounding & Bonding

Article 250 grounding electrode systems, equipment grounding, and bonding

20%

Services, Motors & Special Occupancies

Service entrance, motor circuits, agricultural buildings, hazardous locations, and healthcare

How to Pass the NE Journeyman Electrician Exam

What You Need to Know

  • Passing score: 70%
  • Exam length: 80 questions
  • Time limit: 4 hours
  • Exam fee: $25-$125

Keys to Passing

  • Complete 500+ practice questions
  • Score 80%+ consistently before scheduling
  • Focus on highest-weighted sections
  • Use our AI tutor for tough concepts

NE Journeyman Electrician Study Tips from Top Performers

1Master NEC Article 250 grounding and bonding — it is the most heavily tested topic
2Practice dwelling unit and commercial load calculations using NEC Article 220
3Study agricultural building wiring requirements in Article 547 — relevant for Nebraska's rural areas
4Memorize Table 310.16 conductor ampacity values and temperature correction factors
5Review GFCI and AFCI requirements in Articles 210 and 406 per NEC 2023 updates

Frequently Asked Questions

What NEC edition does Nebraska use for the electrician exam?

Nebraska uses the NEC 2023 edition. A bound copy of the NEC is allowed during the exam. No loose papers or handwritten notes are permitted.

When do Nebraska electrician licenses expire?

All Nebraska electrical licenses expire on December 31 of even-numbered years (e.g., December 31, 2026), regardless of when the license was originally issued. Continuing education is required for renewal.

How much does the Nebraska electrician exam cost?

The exam fee ranges from $25 to $125 depending on the application type and any additional fees. The PSI exam fee is separate from the state licensing application fee.

What experience is required in Nebraska?

Nebraska requires 8,000 hours (approximately 4 years) of electrical work experience under a licensed electrician. Experience must be documented and submitted with your application to the State Electrical Division.