PracticeBlogFlashcardsEspañol
All Practice Exams

100+ Free ND Electrician Practice Questions

Pass your North Dakota Journeyman Electrician License Exam exam on the first try — instant access, no signup required.

✓ No registration✓ No credit card✓ No hidden fees✓ Start practicing immediately
~55% Pass Rate
100+ Questions
100% Free
1 / 100
Question 1
Score: 0/0

According to the NEC, what is the definition of a 'branch circuit'?

A
B
C
D
to track
2026 Statistics

Key Facts: ND Electrician Exam

70%

Passing Score

ND State Electrical Board

80

Exam Questions

PSI

4 hrs

Time Limit

PSI

$25-$50

Exam Fee

PSI

The ND Journeyman Electrician exam requires 70% to pass across 80 multiple-choice questions in 4 hours. It is an open-book exam allowing a bound copy of the 2023 NEC. The exam fee is $25-$50, among the lowest in the country. Candidates need 8,000 hours of experience, with up to 2,000 hours credited for a 2-year electrical program.

Sample ND Electrician Practice Questions

Try these sample questions to test your ND Electrician exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1According to the NEC, what is the definition of a 'branch circuit'?
A.The circuit conductors between the service point and the main disconnecting means
B.The circuit conductors between the final overcurrent device protecting the circuit and the outlet(s)
C.Any circuit that supplies power to a motor
D.The conductors between the transformer and the first overcurrent device
Explanation: Per NEC Article 100, a branch circuit is defined as the circuit conductors between the final overcurrent device protecting the circuit and the outlet(s). This definition is fundamental to understanding how the NEC organizes and regulates different parts of an electrical system.
2In North Dakota, the State Electrical Board requires journeyman electrician applicants to have completed how many hours of experience?
A.4,000 hours
B.6,000 hours
C.8,000 hours
D.10,000 hours
Explanation: North Dakota requires 8,000 hours (approximately 4 years) of electrical experience to qualify for a journeyman electrician license. However, applicants who have completed a 2-year approved electrical program may receive up to 2,000 hours of credit toward this requirement.
3Per NEC 210.8(A), GFCI protection is required for all 125-volt through 250-volt receptacles in which of the following dwelling unit locations?
A.Living rooms
B.Bedrooms
C.Kitchens
D.Closets
Explanation: NEC 210.8(A) requires GFCI protection for 125-volt through 250-volt receptacles in dwelling unit kitchens, along with bathrooms, garages, outdoors, crawl spaces, basements, and other specified locations. The 2023 NEC expanded GFCI requirements significantly.
4What is the minimum size equipment grounding conductor required for a 60-ampere circuit per NEC Table 250.122?
A.14 AWG copper
B.12 AWG copper
C.10 AWG copper
D.8 AWG copper
Explanation: Per NEC Table 250.122, a 60-ampere overcurrent device requires a minimum 10 AWG copper equipment grounding conductor. This table is based on the rating of the overcurrent device protecting the circuit, not the conductor ampacity.
5According to NEC 250.66, what is the minimum size grounding electrode conductor for a 2/0 AWG copper service conductor?
A.8 AWG copper
B.6 AWG copper
C.4 AWG copper
D.2 AWG copper
Explanation: Per NEC Table 250.66, for service conductors sized 2/0 AWG copper (or 4/0 AWG aluminum), the minimum grounding electrode conductor is 4 AWG copper or 2 AWG aluminum. This table correlates the size of the largest service-entrance conductor with the required grounding electrode conductor.
6What is the standard voltage drop recommendation for branch circuits per NEC 210.19(A) Informational Note No. 4?
A.2%
B.3%
C.5%
D.8%
Explanation: NEC 210.19(A) Informational Note No. 4 recommends that voltage drop on branch circuits should not exceed 3%, and the total voltage drop for feeders and branch circuits combined should not exceed 5%. While these are recommendations rather than requirements, they represent good practice.
7Per NEC Table 310.16, what is the ampacity of a 6 AWG THWN-2 copper conductor at 75°C column?
A.40 amperes
B.55 amperes
C.65 amperes
D.75 amperes
Explanation: Per NEC Table 310.16, a 6 AWG copper conductor with a 75°C insulation rating (such as THWN-2 used at 75°C) has an ampacity of 65 amperes. THWN-2 is rated for 90°C but is commonly used at the 75°C column when terminated at equipment rated for 75°C.
8According to NEC 314.16(B), what is the volume allowance for each 12 AWG conductor in a box fill calculation?
A.2.00 cubic inches
B.2.25 cubic inches
C.2.50 cubic inches
D.3.00 cubic inches
Explanation: Per NEC Table 314.16(B), each 12 AWG conductor requires a volume allowance of 2.25 cubic inches in a box fill calculation. This includes equipment grounding conductors counted as one conductor, device yokes counted as two conductors, and clamps counted as one conductor.
9Per NEC 430.52, what is the maximum size dual-element time-delay fuse permitted for motor branch-circuit short-circuit and ground-fault protection for a standard AC motor?
A.125% of motor FLC
B.150% of motor FLC
C.175% of motor FLC
D.250% of motor FLC
Explanation: Per NEC Table 430.52, the maximum rating for a dual-element time-delay fuse used for motor branch-circuit short-circuit and ground-fault protection is 175% of the motor's full-load current. If 175% does not correspond to a standard fuse size, the next higher standard size may be used.
10What is the minimum height above grade for service drop conductors over a residential driveway?
A.10 feet
B.12 feet
C.15 feet
D.18 feet
Explanation: Per NEC 230.24(B)(1), service drop conductors must maintain a minimum clearance of 12 feet above residential driveways and commercial areas not subject to truck traffic. This clearance ensures safe passage of vehicles beneath the conductors.

About the ND Electrician Exam

The North Dakota Journeyman Electrician exam is administered by PSI for the ND State Electrical Board. Based on the 2023 NEC, it covers electrical theory, code compliance, grounding and bonding, wiring methods, load calculations, motors, transformers, and special occupancies. North Dakota grants up to 2,000 hours of credit toward the 8,000-hour experience requirement for graduates of approved 2-year electrical programs.

Questions

80 scored questions

Time Limit

4 hours

Passing Score

70%

Exam Fee

$25-$50 (ND State Electrical Board / PSI)

ND Electrician Exam Content Outline

20%

NEC General & Theory

Definitions, electrical theory, NEC navigation, working space requirements, and installation fundamentals

20%

Branch Circuits & Overcurrent Protection

Circuit sizing, receptacle spacing, GFCI/AFCI requirements, overcurrent protection, and lighting outlets

15%

Grounding & Bonding

Grounding electrode systems, equipment grounding, bonding requirements, and ground-fault protection

20%

Wiring Methods & Materials

Conductor ampacity, conduit fill, cable assemblies, box fill calculations, and raceway types

25%

Services, Feeders, Motors & Special Occupancies

Service entrance requirements, load calculations, motor circuits, transformers, hazardous locations, and healthcare facilities

How to Pass the ND Electrician Exam

What You Need to Know

  • Passing score: 70%
  • Exam length: 80 questions
  • Time limit: 4 hours
  • Exam fee: $25-$50

Keys to Passing

  • Complete 500+ practice questions
  • Score 80%+ consistently before scheduling
  • Focus on highest-weighted sections
  • Use our AI tutor for tough concepts

ND Electrician Study Tips from Top Performers

1Master NEC Article 250 (Grounding and Bonding) — it is heavily tested on every state exam
2Practice dwelling unit load calculations using NEC Article 220 until you can complete them quickly
3Learn to navigate the NEC index efficiently — the exam is open-book and fast lookup saves time
4Focus on conductor ampacity from Table 310.16 and adjustment factors for temperature and conduit fill
5Study motor circuit requirements in Article 430, including overload and short-circuit protection sizing

Frequently Asked Questions

What NEC edition does North Dakota use for the electrician exam?

North Dakota has adopted the 2023 NEC. The PSI-administered exam is open-book, allowing a bound copy of the 2023 NEC. No loose pages, handwritten notes, or removable tabs are permitted.

How many hours of experience are required for a ND journeyman electrician license?

North Dakota requires 8,000 hours of electrical experience under a licensed electrician. Graduates of an approved 2-year electrical school may receive up to 2,000 hours of credit, reducing the on-the-job requirement to 6,000 hours.

How hard is the North Dakota electrician exam?

The exam is challenging with an estimated 55% first-time pass rate. It has 80 questions covering the full NEC with a 4-hour time limit. Strong NEC navigation skills and practice with load calculations are critical for success.

How much does the North Dakota electrician exam cost?

The ND electrician exam fee is approximately $25-$50 through PSI, one of the lowest exam fees in the country. Additional costs include your NEC codebook and any study materials.