12.1 Tertiary Filtration, Membrane Bioreactors and Oregon Recycled Water Classes

Key Takeaways

  • Tertiary filters (sand, dual media, continuous-backwash upflow sand, cloth disks) polish secondary effluent solids and are often paired with metal-salt dosing for low phosphorus limits.

  • MBRs run submerged micro- or ultrafiltration membranes at high MLSS with air scour, relax and backwash cycles; fine screening ahead of them protects the membranes from hair and rags.

  • Oregon Class A recycled water must be filtered to an average of 2 NTU in 24 hours (no more than 5 NTU over 5 percent of the time, never above 10) and disinfected to a 7-day median of 2.2 total coliform per 100 mL.

  • Class B also meets 2.2/23 total coliform but needs no filtration; Class C meets a median of 23 and 240 in two consecutive samples; Class D meets E. coli limits of 126 (30-day log mean) and 406 per 100 mL.

  • Every recycled water program needs DEQ approval of a recycled water use plan and must observe the class's allowed uses, setbacks, signs and harvest restrictions.

Last updated: October 2026

Tertiary Filtration

Secondary clarifier effluent usually carries 5 to 20 mg/L of suspended solids. Tertiary filters remove much of that, along with the phosphorus and BOD bound to those particles.

FilterHow it worksOperating notes
Granular (sand or dual media) gravity filtersDepth filtration through graded media; periodic backwashWatch headloss, effluent turbidity and backwash frequency; solids spikes from the clarifier shorten runs
Continuous-backwash upflow sandInfluent rises through sand while an airlift continuously cleans and returns sandNo shutdowns for backwash; check airlift operation and reject flow
Cloth disk (pile cloth) filtersWater passes outside-in through cloth on rotating disks; vacuum shoes backwash sectionsSmall footprint; watch cloth fouling, grease and solids carryover
Membrane filtrationMF or UF of secondary effluentHighest solids removal; foundation for advanced reuse

Chemical phosphorus polishing: alum or ferric salts are dosed ahead of the filter, sometimes with a small flocculation zone, to precipitate soluble phosphorus. Dose by molar ratio and jar test, monitor alkalinity and pH, and expect more filter solids. DEQ's Table A rates activated sludge with tertiary filtration, including chemical phosphorus removal, as Class III up to 5 MGD.

Membrane Bioreactors (MBR)

An MBR replaces the secondary clarifier with membranes, usually submerged hollow fibers or flat sheets with micro- or ultrafiltration pores, drawing permeate under a slight vacuum.

  • High MLSS, often about 8,000 to 12,000 mg/L, in a small footprint.
  • Fine screening (typically 2 mm or finer) ahead of the MBR is essential. Hair and rags braid around fibers and destroy membranes.
  • Air scour continuously shakes solids off the membrane surface. Permeation cycles include short relax periods and backpulses.
  • Maintenance cleans use dilute sodium hypochlorite for organics and citric or other acids for scale. Periodic recovery cleans restore permeability.
  • Track transmembrane pressure (TMP) and permeability (flux per unit TMP). Falling permeability calls for cleaning or reduced flux.
  • Effluent turbidity is usually well under 1 NTU, an excellent base for Class A recycled water.

Oregon Recycled Water: OAR 340-055

Treated effluent that is suitable for a direct beneficial purpose is recycled water. DEQ permits its use through NPDES or WPCF permits and a DEQ-approved recycled water use plan. The producer must make sure users follow the rules, and users must use it only for the purposes allowed for its class.

ClassTreatmentBacteria criteriaMinimum monitoringExample uses (each class also allows the uses of the classes below it)
NondisinfectedOxidizedNonePer permitIrrigation of fodder, fiber, seed crops not for human ingestion, commercial timber
Class DOxidized and disinfectedE. coli 30-day log mean ≤ 126 per 100 mL; no sample over 406WeeklyFirewood, ornamental nursery stock, Christmas trees, sod, pasture for animals
Class COxidized and disinfectedTotal coliform 7-day median ≤ 23 per 100 mL; ≤ 240 in any two consecutive samplesWeeklyProcessed food crops; orchards and vineyards with direct-to-soil irrigation; golf courses, cemeteries, highway medians, campuses; listed industrial and construction uses; landscape impoundments
Class BOxidized and disinfectedTotal coliform 7-day median ≤ 2.2 per 100 mL; no sample over 233 times per weekStand-alone fire suppression; non-residential toilet and urinal flushing; floor drain trap priming; restricted recreational impoundments
Class AOxidized, filtered and disinfectedBefore disinfection: turbidity average ≤ 2 NTU in 24 hours, ≤ 5 NTU more than 5% of the time, never over 10 NTU. After: total coliform 7-day median ≤ 2.2, no sample over 23Total coliform daily; turbidity hourlyAny agricultural or horticultural irrigation; parks, playgrounds, school yards, residential landscapes; car washes and fountains; nonrestricted recreational impoundments; groundwater recharge under OAR 340-044

Setbacks and site management examples

RequirementNondisinfectedClass DClass CClass B
To a drinking water supply source150 ft100 ft100 ft50 ft
Sprinkler irrigation to property lineSprinklers prohibited without DEQ approval100 ft70 ft10 ft
Spray near food service or drinking fountainsn/a70 ft70 ft10 ft
  • Nondisinfected water: no public access, and no irrigation for 30 days before harvest.
  • Class D: post signs around the irrigation site, keep dairy animals from direct contact, and stop irrigating fodder, sod, nursery stock and similar crops 3 days before harvest.
  • Class C and Class B: post signs at golf courses, cemeteries and impoundments, irrigate processed food crops no closer than 3 days before harvest, and keep edible orchard and vineyard crops off the ground.
  • Class A: no spray onto areas where food is prepared or served, or onto drinking fountains.

Recycled water pipes and appurtenances are color-coded purple and must never be cross-connected to potable water.

Test Your Knowledge

An Oregon plant wants to sell recycled water for irrigating a public school playground. What class is required, and what treatment step distinguishes it from Class B?

A

Nondisinfected water with a 150-foot setback

B

Class A, which adds filtration before disinfection

C

Class C, which requires a weekly E. coli test

D

Class D, which requires warning signs only

Test Your Knowledge

Which numeric criteria apply to Oregon Class C recycled water?

A

Total coliform 7-day median of 2.2 per 100 mL and no sample over 23

B

E. coli 30-day log mean of 126 per 100 mL and no sample over 406

C

Total coliform 7-day median of 23 per 100 mL; no 2 straight samples over 240

D

No bacteria criteria, only a turbidity limit of 2 NTU as a daily average

Test Your Knowledge

An MBR plant's membrane permeability has dropped quickly since a period of heavy rag loading at the headworks. What should the operator check first?

A

The anaerobic digester temperature and mixing

B

The chlorine contact basin and its residual analyzer

C

The fine screens ahead of the membrane tanks

D

The UV lamp intensity readings and sleeve cleaning