5.4 Standard Electrode Potentials (E°) & Predicting Spontaneity

Key Takeaways

  • The standard hydrogen electrode has reference E° = 0 V. The QCAA table uses 298 K, with standard pressure for H₂ and unit activity for H⁺.

  • In the QCAA Formula & Data Book, all half-equations are written as reductions; more positive E° indicates a stronger oxidising agent on the left, while more negative E° indicates a stronger reducing agent on the right.

  • Calculate standard cell potential using E°cell = E°cathode - E°anode; because E° is an intensive property (J C^-1), NEVER multiply E° by stoichiometric coefficients.

  • A reaction is thermodynamically spontaneous under standard conditions when E°cell > 0.

  • Check whether the actual cell matches the standard states and the table's temperature. A positive E°cell describes thermodynamic favourability, independently of reaction speed.

Last updated: November 2026

5.4 Standard Electrode Potentials (E∘E^\circ) & Predicting Spontaneity

A voltmeter connected to a cell measures the potential difference between two electrodes. Standard electrode potentials use a common reference. To compare half-reactions quantitatively, electrochemists assign an exact reference potential of 0.00 V0.00\text{ V} to the Standard Hydrogen Electrode (SHE) and measure every other half-cell against it under standardised laboratory conditions.

The Standard Hydrogen Electrode (SHE)

The SHE operates with hydrogen gas at standard pressure and solvated protons at unit activity. Use 298 K298\text{ K} for the QCAA table; its temperature differs from the 273 K273\text{ K} STP used for gas volumes:

  • Gas & pressure: Pure H2(g)\text{H}_2(\text{g}) bubbled continuously at 100 kPa100\text{ kPa}.
  • Electrolyte: H+(aq)\text{H}^+(\text{aq}) at unit activity, represented as 1.0 mol dm−31.0\text{ mol dm}^{-3} in the ideal classroom concentration model.
  • Electrode: Platinised platinum (Pt(s)\text{Pt}(\text{s}))—platinum coated with finely divided platinum black to maximise catalytic surface area for the equilibrium:
2H+(aq)+2e−⇌H2(g)E∘=0.00 V2\text{H}^+(\text{aq}) + 2e^- \rightleftharpoons \text{H}_2(\text{g}) \qquad E^\circ = 0.00\text{ V}

When a test half-cell is connected to the SHE:

  • If electrons flow from the SHE to the test half-cell, the test half-cell undergoes reduction (cathode) and receives a positive E∘E^\circ (e.g., Cu2+/Cu\text{Cu}^{2+}/\text{Cu}, E∘=+0.34 VE^\circ = +0.34\text{ V}).
  • If electrons flow from the test half-cell to the SHE, the test half-cell undergoes oxidation (anode) and receives a negative E∘E^\circ (e.g., Zn2+/Zn\text{Zn}^{2+}/\text{Zn}, E∘=−0.76 VE^\circ = -0.76\text{ V}).

Reading the QCAA Standard Reduction Potential Table

In the QCAA Chemistry Formula and Data Book (June 2026), every entry in the Standard Electrode Potentials table is written as a reduction half-equation (oxidant+ne−⇌reductant\text{oxidant} + ne^- \rightleftharpoons \text{reductant}). Rather than memorising whether a table lists positive values at the top or bottom, always read the numerical E∘E^\circ values directly:

Reduction Half-EquationE∘E^\circ (V) at 298 K298\text{ K}Relative Redox Strength
MnO4−(aq)+8H+(aq)+5e−⇌Mn2+(aq)+4H2O(l)\text{MnO}_4^-(\text{aq}) + 8\text{H}^+(\text{aq}) + 5e^- \rightleftharpoons \text{Mn}^{2+}(\text{aq}) + 4\text{H}_2\text{O}(\text{l})+1.51+1.51Strongest oxidant among these entries (MnO4−\text{MnO}_4^-)
Cl2(g)+2e−⇌2Cl−(aq)\text{Cl}_2(\text{g}) + 2e^- \rightleftharpoons 2\text{Cl}^-(\text{aq})+1.36+1.36Strong oxidant on left (Cl2\text{Cl}_2)
Ag+(aq)+e−⇌Ag(s)\text{Ag}^+(\text{aq}) + e^- \rightleftharpoons \text{Ag}(\text{s})+0.80+0.80Moderate–strong oxidant (Ag+\text{Ag}^+)
Fe3+(aq)+e−⇌Fe2+(aq)\text{Fe}^{3+}(\text{aq}) + e^- \rightleftharpoons \text{Fe}^{2+}(\text{aq})+0.77+0.77Moderate oxidant (Fe3+\text{Fe}^{3+})
Cu2+(aq)+2e−⇌Cu(s)\text{Cu}^{2+}(\text{aq}) + 2e^- \rightleftharpoons \text{Cu}(\text{s})+0.34+0.34Weak oxidant (Cu2+\text{Cu}^{2+})
2H+(aq)+2e−⇌H2(g)2\text{H}^+(\text{aq}) + 2e^- \rightleftharpoons \text{H}_2(\text{g})0.000.00SHE reference
Fe2+(aq)+2e−⇌Fe(s)\text{Fe}^{2+}(\text{aq}) + 2e^- \rightleftharpoons \text{Fe}(\text{s})−0.44-0.44Moderate reductant on right (Fe\text{Fe})
Zn2+(aq)+2e−⇌Zn(s)\text{Zn}^{2+}(\text{aq}) + 2e^- \rightleftharpoons \text{Zn}(\text{s})−0.76-0.76Strong reductant on right (Zn\text{Zn})
Mg2+(aq)+2e−⇌Mg(s)\text{Mg}^{2+}(\text{aq}) + 2e^- \rightleftharpoons \text{Mg}(\text{s})−2.36-2.36Very strong reductant on right (Mg\text{Mg})
  • More positive E∘E^\circ = greater tendency for reduction; the species on the left is a stronger oxidising agent.
  • More negative E∘E^\circ = greater tendency for the reverse reaction (oxidation); the species on the right is a stronger reducing agent.

Calculating Ecell∘E^\circ_{\text{cell}} (Intensive Property Rule)

For the spontaneous direction under standard conditions, the half-cell with the more positive E∘E^\circ acts as the cathode (reduction), and the half-cell with the more negative E∘E^\circ runs in reverse as the anode (oxidation). Calculate the standard cell potential using:

Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}

where both Ecathode∘E^\circ_{\text{cathode}} and Eanode∘E^\circ_{\text{anode}} are substituted directly as their tabulated reduction potentials (do not flip the sign of Eanode∘E^\circ_{\text{anode}} and also subtract, or you will double-negate!).

Critical Exam Rule: Never Multiply E∘E^\circ by Stoichiometric Coefficients

Consider a Zn/Ag+\text{Zn} / \text{Ag}^+ galvanic cell:

  • Cathode: 2Ag+(aq)+2e−→2Ag(s)2\text{Ag}^+(\text{aq}) + 2e^- \rightarrow 2\text{Ag}(\text{s}), E∘=+0.80 VE^\circ = +0.80\text{ V}
  • Anode: Zn(s)→Zn2+(aq)+2e−\text{Zn}(\text{s}) \rightarrow \text{Zn}^{2+}(\text{aq}) + 2e^-, Ered∘=−0.76 VE^\circ_{\text{red}} = -0.76\text{ V}

Even though the silver half-equation is multiplied by 22 to balance 2e−2e^- in the overall equation (Zn+2Ag+→Zn2++2Ag\text{Zn} + 2\text{Ag}^+ \rightarrow \text{Zn}^{2+} + 2\text{Ag}), the cell potential is:

Ecell∘=(+0.80 V)−(−0.76 V)=+1.56 VE^\circ_{\text{cell}} = (+0.80\text{ V}) - (-0.76\text{ V}) = +1.56\text{ V}

Why? The reversible cell potential measures the Gibbs energy change per unit charge with the opposite sign. Doubling the written reaction doubles both the Gibbs energy change and the charge represented by the balanced equation. Their ratio stays the same.

Predicting Spontaneity and Limitations of E∘E^\circ

To test whether a proposed redox reaction is spontaneous under standard conditions, identify which reactant is reduced (cathode) and which is oxidised (anode), then evaluate Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}:

  • If Ecell∘>0E^\circ_{\text{cell}} > 0, the forward reaction is thermodynamically spontaneous.
  • If Ecell∘<0E^\circ_{\text{cell}} < 0, the forward reaction is non-spontaneous (the reverse reaction is spontaneous).

Example: Under standard conditions, does copper reduce protons to hydrogen? For Cu(s)+2H+(aq)→Cu2+(aq)+H2(g)\text{Cu}(\text{s}) + 2\text{H}^+(\text{aq}) \rightarrow \text{Cu}^{2+}(\text{aq}) + \text{H}_2(\text{g}), H+\text{H}^+ would be reduced (E∘=0.00 VE^\circ = 0.00\text{ V}) and Cu\text{Cu} oxidised (E∘=+0.34 VE^\circ = +0.34\text{ V}). This gives Ecell∘=0.00−(+0.34)=−0.34 V<0E^\circ_{\text{cell}} = 0.00 - (+0.34) = -0.34\text{ V} < 0, so the written proton-to-hydrogen reaction is unfavourable under those conditions. The corresponding zinc reaction gives Ecell∘=0.00−(−0.76)=+0.76 V>0E^\circ_{\text{cell}} = 0.00 - (-0.76) = +0.76\text{ V} > 0, so zinc can reduce protons to hydrogen under the model conditions.

Limitations of E∘E^\circ Predictions (High-Yield EA Short-Response)

Even when Ecell∘E^\circ_{\text{cell}} predicts a clear outcome, laboratory observations can differ for two major reasons:

  1. Conditions of the experiment: The QCAA table gives potentials for standard states at 298 K298\text{ K}. Concentrations, gas pressures and temperature can differ in the actual cell. Changing reactant concentrations shifts half-cell equilibria according to Le Châtelier's principle and alters the actual potential EcellE_{\text{cell}}. If the standard cell potential is close to zero, a change in composition can even reverse the favourable direction.
  2. High activation energy and slow kinetics: A positive Ecell∘E^\circ_{\text{cell}} demonstrates thermodynamic feasibility, not reaction rate. A mixture with Ecell∘>0E^\circ_{\text{cell}} > 0 can appear completely unreactive at 298 K298\text{ K} if its activation energy (EaE_a) is too high—for example, H2(g)\text{H}_2(\text{g}) and O2(g)\text{O}_2(\text{g}) coexist at room temperature without reacting until sparked or catalysed, and acidified MnO4−\text{MnO}_4^- reacts slowly with C2O42−\text{C}_2\text{O}_4^{2-} until warmed or autocatalysed by Mn2+\text{Mn}^{2+}. Additionally, protective oxide layers (such as Al2O3\text{Al}_2\text{O}_3 on aluminium) can kinetically passivate reactive metals.

Comparing Two Cells with the Same Cathode

The table gives +0.34 V+0.34\text{ V} for Cu2+/Cu\text{Cu}^{2+}/\text{Cu}, −0.44 V-0.44\text{ V} for Fe2+/Fe\text{Fe}^{2+}/\text{Fe} and −0.76 V-0.76\text{ V} for Zn2+/Zn\text{Zn}^{2+}/\text{Zn}. The iron–copper cell has 0.34−(−0.44)=+0.78 V0.34-(-0.44)=+0.78\text{ V}. The zinc–copper cell has 0.34−(−0.76)=+1.10 V0.34-(-0.76)=+1.10\text{ V}. Both forward reactions are thermodynamically favourable under standard conditions. Zinc gives the larger standard potential difference for this cathode.

Loading diagram...
Predicting Redox Spontaneity and Evaluating Limitations Using E° Values
Test Your Knowledge

Using the ideal concentration convention for H⁺, which setup represents the standard hydrogen electrode reference for the 298 K QCAA table?

A

273 K, 100 kPa H2(g), 1.0 mol dm^-3 H+(aq), copper electrode

B

298 K, 101.3 kPa H2(g), 0.10 mol dm^-3 H+(aq), graphite electrode

C

298 K, 100 kPa H2(g), 2.0 mol dm^-3 H+(aq), platinum electrode

D

298 K, 100 kPa H2(g), 1.0 mol dm^-3 H+(aq), platinised platinum electrode

Test Your Knowledge

Given Fe3+(aq) + e- <-> Fe2+(aq) (E° = +0.77 V) and Mg2+(aq) + 2e- <-> Mg(s) (E° = -2.36 V), what is the standard cell potential E°cell for Mg(s) + 2Fe3+(aq) -> Mg2+(aq) + 2Fe2+(aq)?

A

+3.91 V

B

+3.13 V

C

-1.60 V

D

+1.60 V

Test Your Knowledge

At standard-state conditions and 298 K, a written redox reaction has E°cell = +0.95 V. A short observation shows no visible change. Which explanation is consistent with the potential?

A

The standard cell potential must be multiplied by the number of electrons transferred before predicting spontaneity.

B

A positive E°cell indicates an endothermic reaction that requires external electrical energy.

C

The forward reaction is thermodynamically favourable, but a kinetic barrier can make its rate very slow.

D

All spontaneous redox reactions reverse direction unless a KNO3 salt bridge is present.

Sections you finish are checked off in the contents.