10.3 Paper/TLC Chromatography (Rf) & Amino-Acid Electrophoresis
Key Takeaways
Paper chromatography can involve partitioning into water held by cellulose. Silica TLC commonly involves adsorption to the solid surface.
Measure the spot centre and solvent front from the same origin, then divide the first distance by the second.
Compare sample and reference spots under the same conditions. A matching Rf supports a proposed identity.
At pH below pI the average charge is positive and migration is to the cathode. At pH above pI the average charge is negative and migration is to the anode.
The pI gives the direction of net movement. Relative distances depend on mobility under the stated conditions.
Paper/TLC Chromatography () & Amino-Acid Electrophoresis
Paper and Thin-Layer Chromatography (TLC)
In ascending planar chromatography, solvent moves up a paper strip or coated plate by capillary action while the stationary phase stays in place. Each solute spends part of its time moving with the solvent and part interacting with the stationary phase. How it distributes between the two affects how far it travels.
- Paper chromatography. The moving phase is a solvent or solvent mixture. In a common setup, cellulose holds water, which can act as a stationary liquid phase. A solute can partition between this retained liquid and the moving solvent.
- Normal-phase silica TLC. Silica is a polar stationary solid. A solute that adsorbs more strongly to silica relative to its attraction to the mobile phase generally moves a shorter distance. Solvent composition affects that competition.
Hydrogen bonding, dipolar interactions and dispersion all affect separation. For amino acids, solvent and pH can also change the species present and its interactions. Use the phases and standards supplied in the problem when ordering spots.
Calculating Retention Factor ()
Use the following measurement rules for planar chromatography.
- Origin and end points: Draw the baseline in graphite pencil (never ink, which dissolves in the solvent and streaks). Measure both distances from the origin line—to the centre of the spot for the component, and to the solvent front (marked before the plate dries) for the solvent.
- Bounds and units: is dimensionless. A resolved spot is between the origin and solvent front. A spot still at the origin gives zero, and a spot indistinguishable from the front is near one. If the calculated ratio exceeds one, recheck both origin measurements and the order of division.
- Controlled comparison condition: An value is a comparison made under matched stationary phase, mobile phase composition and development conditions—ideally spotted side-by-side on the same plate. Even then, two different compounds can share the same in one solvent, so matching supports identity but does not prove it alone.
Worked TLC Example: On a silica TLC plate, the solvent front travels above the pencil origin. Spot A has its centre above the origin and Spot B has its centre above the origin.
Under these conditions, B spends more of the run moving with the solvent, relative to its interaction with the stationary phase. If standards run on the same plate give for serine and for leucine, this supports assigning A to serine and B to leucine. These numbers are example results for one run.
Amino-Acid & Peptide Electrophoresis
In electrophoresis, a direct electric field is applied across a support containing an aqueous buffer. The buffer controls the acid–base environment. A dissolved amino acid can occupy several protonation states, and the average charge governs the direction of net movement.
| Buffer condition | Average net charge | Expected direction in the exam model |
|---|---|---|
| pH below pI | Positive | Towards the negative cathode |
| pH equal to pI | Zero | Stays near the origin |
| pH above pI | Negative | Towards the positive anode |
Two amino acids may migrate in the same direction at a fixed pH. The distance they travel depends on their mobility in that buffer and support, as well as the field and duration. Mobility depends on charge and frictional resistance. A larger pH difference from the pI or a smaller molar mass alone cannot establish which moves farther.
QCAA Chemistry Formula and Data Book (June 2026) pI Values
| Amino Acid | Abbreviation | Side-Chain Character | Isoelectric Point () |
|---|---|---|---|
| Aspartic acid | Asp | Acidic (extra ) | |
| Glutamic acid | Glu | Acidic (extra ) | |
| Alanine | Ala | Neutral non-polar | |
| Glycine | Gly | Neutral non-polar | |
| Histidine | His | Weakly basic side chain | |
| Lysine | Lys | Basic (extra ) | |
| Arginine | Arg | Strongly basic side chain |
Worked Electrophoresis Separation Examples
Example 1: Comparing Directions at pH 6.1
Apply the table to aspartic acid, alanine, histidine and lysine on a strip buffered at pH 6.1.
- Aspartic acid () has a negative average charge and moves towards the anode.
- Alanine (data-book ) has zero average charge in the model and stays near the origin.
- Histidine () and lysine () both have a positive average charge and move towards the cathode. Use reference spots or another run to distinguish them.
At pH 7.6, histidine stays near the origin and lysine still moves towards the cathode, so the second buffer distinguishes the two. If a sample contains alanine and glycine, the data book assigns both . This rule predicts the same direction at a given pH for both. Test an alternative such as chromatography with suitable reference samples.
Example 2: Identify an Unknown from Two Strips
A sample contains two amino acids chosen from aspartic acid, glycine and histidine. On a pH 6.1 strip, one spot stays at the origin and one moves to the cathode. On a fresh pH 7.6 strip, one spot moves to the anode and one stays at the origin.
Glycine () stays at the origin on the first strip and moves towards the anode on the second. Histidine () moves towards the cathode on the first and stays at the origin on the second. Aspartic acid would move towards the anode on both strips. The joint observations support glycine and histidine. Compare the directions relative to each origin, and use the electrode labels rather than the left and right sides of the page.
A student runs a normal-phase silica TLC plate using hexane/ethyl acetate as the mobile phase. The solvent front moves 6.4 cm from the pencil origin line, while Component X forms an oval spot whose bottom edge is 4.4 cm, centre is 4.8 cm, and top edge is 5.2 cm above the origin. Which statement about Component X is correct?
Rf = 1.33, and Component X is strongly adsorbed to the silica stationary phase
Rf = 0.75 using the spot centre and solvent front measured from the origin.
Rf = 0.69, and the value matches any published silica TLC table regardless of solvent
Rf = 0.81, because solvent distance is measured to the top edge of the spot
A mixture of glutamic acid (pI = 3.2), glycine (pI = 6.1), and arginine (pI = 10.7) is separated by paper electrophoresis in a buffer at pH = 6.1. Which migration pattern is observed?
Glutamic acid moves to the cathode (-), glycine moves to the anode (+), and arginine stays at the origin
All three amino acids move toward the anode (+) because pH 6.1 is basic relative to water
Glutamic acid stays at the origin, while glycine and arginine both move toward the cathode (-)
Glutamic acid moves toward the anode (+), glycine remains at the origin, and arginine moves toward the cathode (-)
Which buffer pH is most suitable for separating a mixture of histidine (pI = 7.6), lysine (pI = 9.7), and aspartic acid (pI = 3.0) so that one species moves toward the anode (+), one stays near the origin, and one moves toward the cathode (-)?
pH = 7.6
pH = 3.0
pH = 9.7
pH = 11.0
Sections you finish are checked off in the contents.