5.3 Galvanic Cells: Structure, Ion Migration & Cell Notation

Key Takeaways

  • Galvanic cells convert chemical energy into electrical energy. The laboratory two-beaker design separates the reactants and connects the solutions through a salt bridge.

  • Oxidation always occurs at the anode (negative electrode in a galvanic cell) and reduction always occurs at the cathode (positive electrode in a galvanic cell).

  • Electrons flow through the external wire from anode to cathode, whereas ions migrate through the salt bridge (anions to the anode, cations to the cathode) to maintain electrical neutrality.

  • When the intended redox couple supplies no conducting solid, use a compatible electrode such as platinum to connect the solution to the circuit.

  • For notation written in the galvanic discharge direction, put the anode at left and cathode at right. Use phase boundaries and commas to distinguish separate phases from species in the same solution.

Last updated: November 2026

5.3 Galvanic Cells: Structure, Ion Migration & Cell Notation

When a strip of zinc is placed directly into aqueous CuSO4\text{CuSO}_4, electrons transfer at the metal–solution interface and the process can release heat. A galvanic cell (also called a voltaic cell) can deliver electrical work by directing electrons through an external circuit. The laboratory two-beaker design uses separate half-cells and a salt bridge for ionic connection.

Core Components, Polarity & Charge Flow

This two-beaker design has two charge paths. Electrons move through the external metallic circuit and ions move through the electrolyte and salt bridge.

FeatureAnode Half-CellCathode Half-Cell
Reaction occurringOxidation (loss of e−e^-) — AN OXReduction (gain of e−e^-) — RED CAT
Polarity (galvanic cell)Negative (−-) (source of electrons)Positive (++) (sink for electrons)
External wire flowElectrons exit anode into wireElectrons enter cathode from wire
Salt bridge ion migrationAnions migrate toward anodeCations migrate toward cathode
Active metal mass changeDecreases as metal dissolves (e.g., Zn→Zn2+\text{Zn} \rightarrow \text{Zn}^{2+})Increases as metal deposits (e.g., Cu2+→Cu\text{Cu}^{2+} \rightarrow \text{Cu})

Assigning the Charge Paths

  • AN OX / RED CAT: ANode = OXidation; REDuction = CAThode. (This holds for both galvanic and electrolytic cells.)
  • Alphabetical electron flow: In a galvanic cell delivering current, electrons flow through the wire from Anode to Cathode (A →\rightarrow C).
  • Ion migration: Cations flow to the cathode; anions flow to the anode.

The Salt Bridge & Electrical Neutrality

Without a conducting ion path, charge imbalance rapidly stops sustained current in the two-beaker cell. As Zn(s)→Zn2+(aq)+2e−\text{Zn}(\text{s}) \rightarrow \text{Zn}^{2+}(\text{aq}) + 2e^- proceeds at the zinc anode, excess positive Zn2+\text{Zn}^{2+} charge accumulates in the anode beaker; simultaneously, as Cu2+(aq)+2e−→Cu(s)\text{Cu}^{2+}(\text{aq}) + 2e^- \rightarrow \text{Cu}(\text{s}) proceeds at the copper cathode, positive charge is depleted from the cathode beaker, leaving excess SO42−\text{SO}_4^{2-} anions.

The salt bridge—typically filter paper soaked in a concentrated inert electrolyte such as KNO3(aq)\text{KNO}_3(\text{aq}) or NH4NO3(aq)\text{NH}_4\text{NO}_3(\text{aq})—completes the circuit and maintains near electrical neutrality in both half-cells:

  • Anions (such as NO3−\text{NO}_3^-) migrate from the salt bridge into the anode half-cell to balance newly formed cations.
  • Cations (such as K+\text{K}^+) migrate from the salt bridge into the cathode half-cell to replace reduced cations.

Exam Trap: Choose a salt bridge electrolyte whose ions do not precipitate or react with either half-cell. For example, KCl(aq)\text{KCl}(\text{aq}) must not be used if a half-cell contains Ag+(aq)\text{Ag}^+(\text{aq}), because Ag+\text{Ag}^+ and Cl−\text{Cl}^- precipitate insoluble AgCl(s)\text{AgCl}(\text{s}), blocking ion flow and altering [Ag+][\text{Ag}^+]. Also remember: electrons never travel through the salt bridge or electrolyte.

Inert Electrodes (Platinum and Graphite)

Many redox couples do not include a solid metal capable of acting as an electrode—for example:

  • Aqueous ion/ion couples: Fe3+(aq)/Fe2+(aq)\text{Fe}^{3+}(\text{aq}) / \text{Fe}^{2+}(\text{aq}) or MnO4−(aq),H+(aq)/Mn2+(aq)\text{MnO}_4^-(\text{aq}), \text{H}^+(\text{aq}) / \text{Mn}^{2+}(\text{aq}).
  • Gas/ion couples: H+(aq)/H2(g)\text{H}^+(\text{aq}) / \text{H}_2(\text{g}) or Cl2(g)/Cl−(aq)\text{Cl}_2(\text{g}) / \text{Cl}^-(\text{aq}).

In these half-cells, an inert electrode may be made of platinum (Pt\text{Pt}) or graphite (C\text{C}) is immersed in the solution. The inert electrode conducts electrons into or out of the external circuit and provides a catalytic surface for electron transfer without being consumed or produced in the intended half-reaction. Choose material compatible with the operating conditions.

IUPAC Cell Notation (Cell Diagrams)

Rather than sketching a full apparatus diagram every time, chemists represent a galvanic cell using standard IUPAC cell notation, placing the anode (oxidation) half-cell on the left for a cell written in its discharge direction and the cathode (reduction) half-cell on the right:

Anode∣Anode ion (1 M)∥Cathode ion (1 M)∣Cathode\text{Anode} \mid \text{Anode ion } (1\text{ M}) \parallel \text{Cathode ion } (1\text{ M}) \mid \text{Cathode}

Notice the punctuation conventions (where 1 M1\text{ M} denotes the standard 1.0 mol dm−31.0\text{ mol dm}^{-3} concentration):

  • Single vertical line (∣\mid): Represents a phase boundary (for example, solid metal in contact with an aqueous solution, or gas in contact with an aqueous solution).
  • Double vertical line (∥\parallel): Represents the liquid junction, drawn here as a salt bridge between the two half-cells.
  • Comma (,,): Separates two species in the same phase (typically two dissolved aqueous species in the same beaker).

Worked Cell-Notation Examples

  1. Zinc–copper (Daniell) cell:
Zn(s)∣Zn2+(aq,1 M)∥Cu2+(aq,1 M)∣Cu(s)\text{Zn}(\text{s}) \mid \text{Zn}^{2+}(\text{aq}, 1\text{ M}) \parallel \text{Cu}^{2+}(\text{aq}, 1\text{ M}) \mid \text{Cu}(\text{s})
  1. Zinc–iron(III)/iron(II) cell (requiring an inert Pt\text{Pt} cathode): Both Fe3+\text{Fe}^{3+} and Fe2+\text{Fe}^{2+} are aqueous in the right-hand beaker, so they are separated by a comma, with Pt(s)\text{Pt}(\text{s}) placed at the outer right terminal:
Zn(s)∣Zn2+(aq,1 M)∥Fe3+(aq,1 M),Fe2+(aq,1 M)∣Pt(s)\text{Zn}(\text{s}) \mid \text{Zn}^{2+}(\text{aq}, 1\text{ M}) \parallel \text{Fe}^{3+}(\text{aq}, 1\text{ M}), \text{Fe}^{2+}(\text{aq}, 1\text{ M}) \mid \text{Pt}(\text{s})
  1. Standard hydrogen–silver cell (gas anode with inert Pt\text{Pt}): Place the inert electrode at the far left before the gas phase boundary:
Pt(s)∣H2(g,100 kPa)∣H+(aq,1 M)∥Ag+(aq,1 M)∣Ag(s)\text{Pt}(\text{s}) \mid \text{H}_2(\text{g}, 100\text{ kPa}) \mid \text{H}^+(\text{aq}, 1\text{ M}) \parallel \text{Ag}^+(\text{aq}, 1\text{ M}) \mid \text{Ag}(\text{s})

When reading cell notation in an exam question, immediately split the string at ∥\parallel: everything to the left represents the oxidation half-reaction, and everything to the right represents the reduction half-reaction.

Worked Interpretation: From Cell Notation to Experimental Observations

Consider a model cell with a clean active zinc electrode, represented as Zn(s)∣Zn2+(aq,1 M)∥Cu2+(aq,1 M)∣Cu(s)\text{Zn}(\text{s}) \mid \text{Zn}^{2+}(\text{aq}, 1\text{ M}) \parallel \text{Cu}^{2+}(\text{aq}, 1\text{ M}) \mid \text{Cu}(\text{s}) with an NH4NO3(aq)\text{NH}_4\text{NO}_3(\text{aq}) salt bridge:

  1. Identify half-cells and reactions: Zinc sits left of ∥\parallel, so it is the negative anode undergoing oxidation (Zn(s)→Zn2+(aq)+2e−\text{Zn}(\text{s}) \rightarrow \text{Zn}^{2+}(\text{aq}) + 2e^-). Copper sits right of ∥\parallel, so it is the positive cathode undergoing reduction (Cu2+(aq)+2e−→Cu(s)\text{Cu}^{2+}(\text{aq}) + 2e^- \rightarrow \text{Cu}(\text{s})).
  2. Overall balanced equation: Each half-equation uses two electrons. Adding and cancelling them gives Zn(s)+Cu2+(aq)→Zn2+(aq)+Cu(s)\text{Zn(s)} + \text{Cu}^{2+}\text{(aq)} \rightarrow \text{Zn}^{2+}\text{(aq)} + \text{Cu(s)}.
  3. Macroscopic observations: Over time, the zinc electrode loses mass as it dissolves, the copper electrode gains mass as reddish-brown copper plates onto it, and the blue colour of the Cu2+(aq)\text{Cu}^{2+}(\text{aq}) solution fades. Simultaneously, electrons flow externally from Zn\text{Zn} to Cu\text{Cu}, while NO3−\text{NO}_3^- anions migrate into the Zn2+\text{Zn}^{2+} half-cell and NH4+\text{NH}_4^+ cations migrate into the Cu2+\text{Cu}^{2+} half-cell.
Loading diagram...
Charge Flow in a Zn/Cu Galvanic Cell (External Electrons vs Salt-Bridge Ions)
Test Your Knowledge

In a galvanic cell constructed from a magnesium half-cell (Mg/Mg2+) and a silver half-cell (Ag/Ag+) linked by a KNO3(aq) salt bridge, which statement correctly describes charge movement during discharge?

A

Electrons flow through the salt bridge from Mg to Ag, while K+ ions move toward the Mg half-cell.

B

Electrons flow through the wire from Ag to Mg, while NO3- ions move toward the Ag half-cell.

C

Electrons flow through the external wire from Mg to Ag, while K+ ions migrate into the Ag+ half-cell.

D

NO3- ions enter the Ag+ half-cell to balance the deposition of solid silver.

Test Your Knowledge

A galvanic cell is written in its discharge direction. Iron is oxidised to Fe²⁺ and acidified permanganate is reduced to Mn²⁺ at a platinum electrode. Which line notation matches the stated processes?

A

Pt(s) | MnO4-(aq, 1 M), H+(aq, 1 M), Mn2+(aq, 1 M) || Fe2+(aq, 1 M) | Fe(s)

B

Fe(s) | Fe2+(aq, 1 M) || MnO4-(aq, 1 M), H+(aq, 1 M), Mn2+(aq, 1 M) | Pt(s)

C

Fe(s) || Fe2+(aq, 1 M) | MnO4-(aq, 1 M) | Mn2+(aq, 1 M) | Pt(s)

D

Fe(s) | Fe2+(aq, 1 M) || MnO4-(aq, 1 M) | H+(aq, 1 M) | Mn2+(aq, 1 M) | Pt(s)

Test Your Knowledge

Why should KCl(aq) NOT be used as the salt bridge electrolyte in a galvanic cell containing an Ag(s) | Ag+(aq) half-cell?

A

Cl- ions react with Ag+ ions to form insoluble AgCl(s), disrupting ion migration and altering [Ag+].

B

K+ ions will be preferentially reduced at the cathode instead of Ag+ ions.

C

Cl- ions carry electrons across the salt bridge, short-circuiting the voltmeter.

D

KCl(aq) is a weak electrolyte that cannot conduct ions in aqueous solution.

Sections you finish are checked off in the contents.