11.4 Hydrogen Fuel Cells (Acidic & Alkaline) & Energy Design

Key Takeaways

  • A hydrogen-oxygen fuel cell is a galvanic cell that converts chemical energy spontaneously into electrical energy using a continuous external supply of H2 and O2 rather than stored internal reactants

  • In an acidic (PEM) fuel cell, H2 -> 2H+ + 2e- occurs at the negative anode, O2 + 4H+ + 4e- -> 2H2O occurs at the positive cathode, and H+ ions migrate from anode to cathode

  • In an alkaline (KOH) fuel cell, H2 + 2OH- -> 2H2O + 2e- occurs at the negative anode, O2 + 2H2O + 4e- -> 4OH- occurs at the positive cathode, and OH- ions migrate from cathode to anode

  • Both acidic and alkaline hydrogen fuel cells share the identical overall equation 2H2(g) + O2(g) -> 2H2O(l) and standard cell potential E_cell = +1.23 V

  • Porous catalytic layers provide access for reactant gas, electrolyte ions and electrons. Separate the cell reaction from losses and emissions elsewhere in the system.

Last updated: November 2026

Hydrogen Fuel Cells (Acidic & Alkaline) & Energy Design

A hydrogen–oxygen fuel cell is an electrochemical cell that converts the chemical energy of externally supplied hydrogen and oxygen into electrical work through a spontaneous redox reaction. Its oxidation and reduction electrodes follow the galvanic principles in Chapter 5.

Comparing Fuel Cells, Primary/Secondary Galvanic Cells & Electrolytic Cells

FeatureConventional Galvanic Battery in DischargeHydrogen–Oxygen Fuel CellElectrolytic Cell
Energy ConversionChemical →\rightarrow Electrical (spontaneous)Chemical →\rightarrow Electrical (spontaneous)Electrical →\rightarrow Chemical (non-spontaneous)
Reactant SupplyFinite inventory of active materialsExternal supply of H2\text{H}_2 and O2\text{O}_2Power source drives conversion of available reactants
Anode Polarity & ReactionNegative (−-), oxidationNegative (−-), oxidation of H2\text{H}_2Positive (++), oxidation
Cathode Polarity & ReactionPositive (++), reductionPositive (++), reduction of O2\text{O}_2Negative (−-), reduction
Continued OperationCapacity falls during discharge. Secondary cells can be rechargedDepends on reactant supply and cell conditionRequires a sufficient applied voltage

Because fuel cells are galvanic in operation, AN OX (anode = oxidation) and RED CAT (cathode = reduction) hold just as in any galvanic cell, and the anode is negative (−-) while the cathode is positive (++).

Acidic (PEM) vs Alkaline (KOH\text{KOH}) Fuel Cell Equations

Regardless of whether the electrolyte is acidic or alkaline, the overall net cell equation is identical:

2H2(g)+O2(g)→2H2O(l)2\text{H}_2\text{(g)} + \text{O}_2\text{(g)} \rightarrow 2\text{H}_2\text{O(l)}

Use acidic or alkaline forms of the half-equations according to the electrolyte. The transferred ions cancel when the half-equations are added.

1. Acidic Hydrogen Fuel Cell (Proton Exchange Membrane, PEM)

A proton exchange membrane conducts protons, separates the gas feeds and is electronically insulating. The half-equations use the data-book acidic notation:

  • Anode (−-, oxidation): H2(g)→2H+(aq)+2e−\text{H}_2\text{(g)} \rightarrow 2\text{H}^+\text{(aq)} + 2e^- (tabulated reduction potential 0.00 V0.00\text{ V})
  • Cathode (++, reduction): O2(g)+4H+(aq)+4e−→2H2O(l)\text{O}_2\text{(g)} + 4\text{H}^+\text{(aq)} + 4e^- \rightarrow 2\text{H}_2\text{O(l)} (E∘=+1.23 VE^\circ = +1.23\text{ V})
  • Overall (doubling anode and cancelling 4e−4e^- and 4H+4\text{H}^+): 2H2(g)+O2(g)→2H2O(l)2\text{H}_2\text{(g)} + \text{O}_2\text{(g)} \rightarrow 2\text{H}_2\text{O(l)}
  • Standard EMF: Ecell∘=Ecathode∘−Eanode∘=+1.23−0.00=+1.23 VE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = +1.23 - 0.00 = +1.23\text{ V}.
  • Ion migration: Electrons travel through the external wire from anode to cathode; inside the cell, H+\text{H}^+ ions migrate from the anode to the cathode through the membrane to maintain electrical neutrality and supply H+\text{H}^+ for oxygen reduction.

2. Alkaline Hydrogen Fuel Cell (KOH\text{KOH} Electrolyte)

In concentrated aqueous KOH(aq)\text{KOH(aq)}, hydroxide ions (OH−\text{OH}^-) serve as the charge carrier:

  • Anode (−-, oxidation): H2(g)+2OH−(aq)→2H2O(l)+2e−\text{H}_2\text{(g)} + 2\text{OH}^-\text{(aq)} \rightarrow 2\text{H}_2\text{O(l)} + 2e^- (or doubled: 2H2(g)+4OH−(aq)→4H2O(l)+4e−2\text{H}_2\text{(g)} + 4\text{OH}^-\text{(aq)} \rightarrow 4\text{H}_2\text{O(l)} + 4e^-). The tabulated reduction potential for the reverse half-reaction is −0.83 V-0.83\text{ V}.
  • Cathode (++, reduction): O2(g)+2H2O(l)+4e−→4OH−(aq)\text{O}_2\text{(g)} + 2\text{H}_2\text{O(l)} + 4e^- \rightarrow 4\text{OH}^-\text{(aq)} (E∘=+0.40 VE^\circ = +0.40\text{ V})
  • Overall (cancelling 4e−4e^-, 4OH−4\text{OH}^-, and 2H2O2\text{H}_2\text{O}): 2H2(g)+O2(g)→2H2O(l)2\text{H}_2\text{(g)} + \text{O}_2\text{(g)} \rightarrow 2\text{H}_2\text{O(l)}
  • Standard EMF: Ecell∘=+0.40−(−0.83)=+1.23 VE^\circ_{\text{cell}} = +0.40 - (-0.83) = +1.23\text{ V}. Use the tabulated reduction potential for each electrode without multiplying the voltage by its balancing coefficient.
  • Ion migration: Because OH−\text{OH}^- ions are generated at the cathode and consumed at the anode, OH−\text{OH}^- ions migrate from the cathode to the anode through the KOH\text{KOH} electrolyte.

In an alkaline cell, carbon dioxide can react with hydroxide: CO2+2OH−→CO32−+H2O\text{CO}_2+2\text{OH}^-\rightarrow\text{CO}_3^{2-}+\text{H}_2\text{O}. Carbonation can reduce cell performance. Traditional liquid-alkaline systems can use scrubbed air or pure oxygen to limit this reaction.

Porous Catalytic Electrodes and Charge

A porous catalytic electrode brings reactant gas, an ion-conducting electrolyte and an electron-conducting solid into contact. A catalyst increases the rate of the electrode reaction. For example, platinum-based catalysts are used in many proton exchange membrane cells. Real voltage under load is below the reversible voltage because of activation, resistance and transport losses. The cell potential also depends on operating conditions.

Worked Example: Faraday's Law Applied to a Hydrogen Fuel Cell

A hydrogen fuel cell delivers a steady current of 10.0 A10.0\text{ A} for 30.0 minutes30.0\text{ minutes} (1800 s1800\text{ s}). Assume all measured current comes from the stated hydrogen oxidation reaction. Using F=96 485 C mol−1F = 96\,485\text{ C mol}^{-1} from the QCAA Formula and Data Book, calculate the volume of H2(g)\text{H}_2\text{(g)} consumed at STP (273 K,100 kPa,Vm=22.7 dm3 mol−1273\text{ K}, 100\text{ kPa}, V_m = 22.7\text{ dm}^3\text{ mol}^{-1}).

  1. Charge transferred: Q=It=10.0×1800=18 000 CQ = It = 10.0 \times 1800 = 18\,000\text{ C}.
  2. Moles of electrons: n(e−)=QF=18 00096 485=0.1866 moln(e^-) = \frac{Q}{F} = \frac{18\,000}{96\,485} = 0.1866\text{ mol}.
  3. From H2→2H++2e−\text{H}_2 \rightarrow 2\text{H}^+ + 2e^- (or H2+2OH−→2H2O+2e−\text{H}_2 + 2\text{OH}^- \rightarrow 2\text{H}_2\text{O} + 2e^-), 1 mol H21\text{ mol H}_2 supplies 2 mol e−2\text{ mol }e^-:
n(H2)=0.18662=0.0933 moln(\text{H}_2) = \frac{0.1866}{2} = 0.0933\text{ mol}
  1. STP gas volume: V(H2)=0.0933×22.7=2.12 dm3V(\text{H}_2) = 0.0933 \times 22.7 = 2.12\text{ dm}^3.

Energy and System Boundaries

The net cell reaction makes water. With pure hydrogen and oxygen there is no carbon in the chemical equation, so it gives no carbon dioxide at the cell. The emissions associated with supplying hydrogen depend on how the hydrogen is produced, compressed and transported. Natural gas reforming produces carbon dioxide. The emissions from electrolytic hydrogen depend in part on the electricity source.

Direct electrochemical conversion can provide electrical work without a combustion-driven heat engine. Comparing efficiency requires the same system boundary and the same heating-value convention. For example, compression of the incoming gases can consume part of the electricity generated. In a comparison question, separate the ideal electrode voltage, the output of the real stack and the performance of the complete system.

Loading diagram...
Ion and Electron Flow in Acidic (PEM) vs Alkaline (KOH) Hydrogen Fuel Cells
Test Your Knowledge

In an alkaline (KOH) hydrogen-oxygen fuel cell, which cathode half-equation and ion-migration direction are correct?

A

O2(g) + 4H+(aq) + 4e- -> 2H2O(l), with H+ migrating from anode to cathode

B

H2(g) + 2OH-(aq) -> 2H2O(l) + 2e-, with OH- migrating from anode to cathode

C

O2(g) + 2H2O(l) + 4e- -> 4OH-(aq), with OH- migrating from anode to cathode

D

O2(g) + 2H2O(l) + 4e- -> 4OH-(aq), with OH- migrating from cathode to anode

Test Your Knowledge

A hydrogen fuel cell supplies a constant current of 19.3 A for 1000 s (F = 96 485 C mol^-1). Assuming all measured current comes from hydrogen oxidation, what volume of H2(g) at STP (273 K, 100 kPa, V_m = 22.7 dm^3 mol^-1) is consumed?

A

1.14 dm^3

B

2.27 dm^3

C

4.54 dm^3

D

9.08 dm^3

Test Your Knowledge

Which statement best distinguishes a hydrogen-oxygen fuel cell from both a primary galvanic battery and an electrolytic cell?

A

A fuel cell drives a non-spontaneous reaction using external DC electricity, whereas a primary battery stores energy permanently.

B

A fuel cell has a positive anode and negative cathode, matching the polarity of an electrolytic cell.

C

A hydrogen fuel cell generates electrical energy by spontaneous reaction of externally supplied hydrogen and oxygen.

D

A fuel cell achieves 100% energy efficiency because no heat is ever released during operation.

Sections you finish are checked off in the contents.

Congratulations!

You've completed this section

Continue exploring other exams