4.2 Volumetric Analysis, Glassware Rinsing & Primary Standards
Key Takeaways
Use a primary standard of known purity and composition that can be handled accurately and reacts in a known mole ratio.
Final glassware rinsing follows a strict rule: rinse pipettes and burettes with the solution they deliver, but rinse volumetric flasks and conical flasks with deionised water only.
Use the concordance tolerance specified by the method or question. Exclude the rough titre and average only the accepted trials.
In dilution-plus-aliquot and back-titration problems, track total moles in the volumetric flask separately from moles in the titrated aliquot before applying stoichiometric mole ratios.
4.2 Volumetric Analysis, Glassware Rinsing & Primary Standards
Volumetric analysis determines an unknown concentration (or mass percentage) by reacting a measured volume of analyte with a standard solution of accurately known concentration. Achieving high accuracy in the QCE Chemistry syllabus requires choosing a valid primary standard, preparing it cleanly, rinsing each piece of glassware correctly, and tracking mole ratios carefully across dilutions.
Primary Standards & Preparing a Standard Solution
Common laboratory reagents such as and concentrated cannot be used directly as primary standards: solid is hygroscopic (absorbs atmospheric water) and reacts with atmospheric to form , while concentrated loses by volatilisation. Instead, they are reagents used to prepare solutions that can be standardised against a suitable reference. A solution whose concentration has been established by comparison is a secondary standard.
Check four practical properties when choosing a primary standard.
- High, known purity with a well-characterised composition and uncertainty.
- Stability in air: Non-hygroscopic, non-efflorescent (does not lose water of crystallisation), and unreactive with atmospheric or .
- Adequate mass for weighing: A higher molar mass is useful when it allows more material to be weighed for the same amount in moles, lowering relative weighing uncertainty.
- Ready solubility and stoichiometric reactivity: Dissolves completely in water and reacts rapidly without side reactions.
Anhydrous sodium carbonate (, ) can be used to standardise acids. Potassium hydrogen phthalate (KHP, , ) can be used to standardise bases. Follow the handling instructions for the standard you actually use.
Steps to Prepare a Standard Solution ( Volumetric Flask)
- Prepare the primary standard as specified by its handling instructions. Weigh the transferred mass by difference on an analytical balance.
- Dissolve completely in a small volume of deionised water, stirring with a glass rod.
- Transfer quantitatively through a funnel into a volumetric flask pre-rinsed with deionised water only; rinse the beaker, rod, and funnel several times with deionised water into the flask.
- Add deionised water until the meniscus approaches the calibration mark, then add drop-wise using a Pasteur pipette until the bottom of the meniscus sits level with the mark at eye height (preventing parallax error).
- Stopper and invert repeatedly to produce a homogeneous solution.
Final Glassware Rinsing Rules & Error Direction
Every piece of volumetric glassware is initially washed and rinsed with deionised water. The final rinse before use depends on whether the glassware delivers a known concentration or holds a known number of moles:
- Pipette and burette (final rinse: the solution they will deliver): Any residual droplets of deionised water left inside would dilute the solution being delivered, changing its concentration.
- Volumetric flask and conical flask (final rinse: deionised water only): Residual deionised water does not alter the total number of moles of solute placed inside (and in a volumetric flask, the total volume is subsequently made up to the calibration mark anyway).
| Glassware | Correct Final Rinse | Error If Rinsed Wrongly | Effect on Titre & Calculated Analyte Concentration |
|---|---|---|---|
| Volumetric flask | Deionised water only | Rinsed with standard solution | Extra solute remains; actual is higher than calculated; if used as titrant, produces a smaller titre and underestimates analyte concentration |
| Conical flask | Deionised water only | Rinsed with analyte solution | Extra analyte moles enter flask; requires a larger titre, overestimating analyte concentration |
| Conical flask | Deionised water only | Rinsed with titrant | Some analyte is pre-neutralised before titration starts; gives a smaller titre, underestimating analyte concentration |
| Pipette (delivering analyte) | Analyte solution | Left wet with deionised water | Aliquot is diluted; fewer moles of analyte enter conical flask, giving a smaller titre and underestimating analyte concentration |
| Burette (delivering standard titrant) | Standard titrant | Left wet with deionised water | Titrant is diluted; a larger titre is needed to supply the same moles of titrant, overestimating analyte concentration |
Concordant Titres & Worked Dilution Calculation
In titration experiments, the first trial is typically a rough rangefinder run and is excluded from calculations. Look for closely agreeing repeated values. For the following worked example, the method accepts three titres with a highest-to-lowest spread of at most . Apply the stated method or question tolerance rather than assuming that it is universal.
Worked Example 1: Dilution + Aliquot Titration
Question: A sample of commercial vinegar is pipetted into a volumetric flask and diluted to the mark with deionised water. Next, aliquots of the diluted vinegar are titrated against using phenolphthalein. The recorded titres are: Rough , Trial 1 , Trial 2 , Trial 3 , Trial 4 . Calculate the molar concentration of ethanoic acid () in the original undiluted vinegar.
Solution:
- Select concordant titres: Trials 1, 2, and 3 () span , so they are concordant. The rough trial and Trial 4 () are excluded.
- Mean concordant titre:
- Moles of and in the aliquot: From ( stoichiometry):
- Scale from aliquot to the volumetric flask:
- Concentration of the original () vinegar:
Back-Titration Calculations
A back-titration is used when a direct titration is impractical—for example, when the analyte is an insoluble solid (such as in limestone or antacid tablets), reacts too slowly, or is volatile (such as ). A precisely known excess of standard reagent A is added to consume the analyte completely, and the remaining unreacted A is titrated with standard reagent B.
Worked Example 2: Antacid Tablet Back-Titration
Question: A antacid tablet containing calcium carbonate (, ) is reacted with of (an excess). Assume other ingredients consume no acid and the dissolved has been removed before back-titration. The unreacted excess requires of to reach the end point. Calculate the percentage by mass of in the tablet.
Solution:
- Total initial moles of added:
- Moles of excess neutralised by ( ratio):
- Moles of that reacted with :
- Moles and mass of : From ( ratio):
- Percentage by mass of :
Exam Trap — Back-Titration with Dilution: If the reaction mixture containing excess is instead transferred to a volumetric flask and a aliquot is titrated, always scale up by before subtracting from .
Worked Example 3: Measuring Solubility by Titration
A filtered sample of saturated calcium hydroxide solution takes of hydrochloric acid to reach equivalence. Assume dissolved calcium hydroxide supplies the hydroxide and there is no undissolved solid in the aliquot. The measured acid amount, , equals the amount of hydroxide.
The sample represents half that amount of dissolved calcium hydroxide, . Divide by to obtain its molar solubility, . With a molar mass of , the result is . An unfiltered sample would be unsuitable because suspended solid could dissolve as acid is added and consume extra titrant.
Why is solid sodium hydroxide (NaOH) unsuitable as a primary standard in volumetric analysis?
It has too high a molar mass to dissolve rapidly in water.
It absorbs atmospheric moisture and carbon dioxide, so its true mass of NaOH is uncertain.
It reacts too slowly with strong acids such as HCl.
It cannot form a homogeneous solution in a volumetric flask.
A student titrates 25.00 cm3 aliquots of an unknown HCl solution in a conical flask against standard NaOH from a burette. Which rinsing error would cause the calculated concentration of HCl to be higher than its true value?
Rinsing the pipette with deionised water immediately before transferring the HCl aliquot
Rinsing the conical flask with deionised water immediately before adding the HCl aliquot
Rinsing the conical flask with standard NaOH before adding the HCl aliquot
Rinsing the burette with deionised water immediately before filling it with standard NaOH
A method accepts three concordant titres with a spread of at most 0.10 cm³. The results are 18.90 (rough), 18.35, 18.25, 18.60 and 18.30 cm³. What is the mean of the accepted titres?
18.30 cm3
18.38 cm3
18.48 cm3
18.32 cm3
Sections you finish are checked off in the contents.