Which section of a safety data sheet lists recommended personal protective equipment?

Tap to reveal definition
Card 1 of 50Safety

Filter by Topic

Jump to Card

About These NATE Core Flashcards

These 50 flashcards are designed to help you memorize key terms and definitions for the NATE Core Knowledge Exam. Each card shows a term on the front and its definition on the back—the classic flashcard format for vocabulary memorization. Use these alongside our practice questions to build both recall and comprehension.

Topics Covered

Safety9 cards
Tools5 cards
Basic Construction4 cards
Using Basic Science5 cards
Achieving Desired Conditions7 cards
Taking Temperature & Humidity Measurements7 cards
Basic Electricity13 cards

Complete Flashcard Reference

Review every term in this set. Open any term to reveal its definition.

Which section of a safety data sheet lists recommended personal protective equipment?

Section 8, Exposure Controls/Personal Protection. It also lists applicable exposure limits and engineering controls.

What makes a ground-fault circuit interrupter (GFCI) trip?

It cuts power when current leaving the circuit differs enough from the current returning. The imbalance indicates current may be flowing along an unintended path.

Why can a capacitor remain hazardous after you lock out the equipment supply?

It can retain an electrical charge. Follow the equipment’s safe discharge procedure and verify that hazardous stored energy has been controlled before service.

Why can nitrogen leaking into a confined space make the air unsafe to breathe?

Nitrogen can displace oxygen. Follow the confined-space procedure and have the atmosphere tested before any authorized entry.

Can you use a stepladder’s top cap as a step?

No. Use a taller ladder if reaching the work would require standing on the top cap or top step.

What can form inside a copper tube if air remains in it during brazing?

Copper oxide scale can form and break loose inside the system. Flowing dry nitrogen as directed by the equipment manufacturer displaces the air and limits scale.

How should a compressed-gas cylinder used for brazing be secured at a construction site?

Secure it upright with a cylinder cart, chain, or other suitable restraint so it cannot tip over during use.

On an ABC extinguisher label, what does the letter C identify?

Suitability for a fire involving energized electrical equipment. Follow your site’s emergency plan.

Does attaching pressure gauges to a covered stationary refrigerant system count as work under EPA Section 608?

Yes. EPA includes attaching and detaching gauges in technician activities. Apprentices are exempt only when closely and continually supervised by a certified technician.

On a drawing at ¼ inch = 1 foot, what actual distance does a 1¾-inch line represent?

7 feet. Each inch on the drawing represents 4 feet, so multiply 1¾ by 4.

Which tool tells you whether a vertical equipment support is plumb?

A spirit level with a vertical vial. A centered bubble in that vial indicates the support is vertical.

What does a reamer remove after you cut copper tubing?

It removes the burr left at the cut edge. Deburring helps prepare the end for a fitting or for forming a flare.

What is the difference between swaging a copper tube end and flaring it?

Swaging expands the end into a socket for another tube of the same original size. Flaring forms a tapered lip that seats against a matching fitting.

Why use a correctly sized tubing bender on a tight bend?

The bender supports the tube through a controlled radius, reducing the chance that the tube will flatten or kink.

Where should you check a duct’s specified material and insulation requirements?

Check the project specifications for material and installation requirements. Use the drawings to locate the duct and coordinate its route.

What is the clear span of a truss?

The inside-to-inside distance between its bearing points. Measure between the facing sides of the supports.

On a building plan, what does fenestration refer to?

Openings and assemblies such as windows, skylights, and glazed doors. Their locations and performance affect heat gain and loss.

What should you do if a planned duct route crosses a roof truss member?

Coordinate a different route or obtain approval from a registered design professional before altering the truss. The member is part of an engineered load path.

What toxic gas can form when a carbon-based fuel burns incompletely?

Carbon monoxide (CO). It is colorless and odorless, so smell cannot reveal its presence.

A sealed gas occupies 3 ft³ at 28 psia. What is its pressure if the volume drops to 1.5 ft³ at constant temperature?

56 psia. Boyle’s law keeps absolute pressure times volume constant for a fixed amount of ideal gas at constant temperature.

What current flows through a 12 Ω resistor with 18 V DC across it?

1.5 A. Ohm’s law gives current as voltage divided by resistance, so 18 ÷ 12 = 1.5.

Two parallel loads draw 0.8 A and 1.3 A from the same DC supply. What current does the supply deliver?

2.1 A. The supply current is the sum of the two branch currents.

What is the cross-sectional area of a round duct with a 10-inch inside diameter?

About 78.5 in². Use πr² with a 5-inch inside radius.

Why can you feel colder beside a cold window even if the room air temperature is uniform?

Your body loses more heat by radiation to the colder surface. Comfort depends partly on the temperatures of surrounding surfaces.

Why can a short-cycling, oversized air conditioner leave a room humid?

It can satisfy the thermostat before the cooling coil has had enough run time to condense and drain much moisture.

How does a bathroom exhaust fan vented outdoors control shower moisture?

It removes humid air near the source before much of that moisture spreads to other rooms.

How does outdoor-air ventilation lower the concentration of an indoor-generated pollutant?

When the outdoor air is cleaner, exchanging it with indoor air dilutes the pollutant and carries some of it out of the building.

Why does a gap beside an HVAC filter reduce filtration?

Some air goes around the filter media through the gap, so particles in that air can recirculate even when the filter is efficient.

What airflow condition can cause a hiss at a supply grille?

High air velocity or turbulence at the opening can generate noise. A restriction or a sharp turn near the grille can contribute.

Why can a draft make a person feel cold without changing the thermostat reading?

Faster air moving past the body can increase convective heat loss, making the person feel cooler at the same air temperature.

A cooling coil condenses water vapor. What type of heat does that phase change release?

Latent heat. The coil absorbs energy released as vapor becomes liquid. Sensible cooling is the drop in air temperature.

What heat-transfer mechanism moves heat through the solid wall of a metal tube?

Conduction. Energy passes through the material from the warmer side toward the cooler side.

What does Btu/h express on an HVAC equipment rating?

A rate of heat transfer or capacity. A Btu measures an amount of energy, and Btu/h states how much energy is transferred per hour.

What temperature does an infrared thermometer read when aimed at a supply grille?

It estimates the grille’s surface temperature. To measure supply-air temperature, place a suitable air probe in the airstream.

Why does a ventilated wet-bulb thermometer usually read lower than dry bulb?

Water evaporating from the wet wick cools the sensor. In saturated air, there is no net evaporative cooling and the readings coincide.

Room air has a dew point of 58°F. What can happen on an exposed pipe surface at 52°F?

Water can condense on the pipe. The surface cools nearby air below its dew point.

At the same dry-bulb temperature, does the drier or more humid air sample have higher enthalpy?

The more humid one. At the same temperature, a higher humidity ratio raises moist-air enthalpy per pound of dry air.

What is the state of a normally open relay contact when its coil is de-energized?

The contact is open. In a standard relay, energizing the coil closes the normally open contact.

Which diagram shows where field-installed thermostat conductors connect at the unit?

Use the equipment’s field wiring diagram. It identifies terminal connections for on-site wiring.

A ladder diagram shows two safety switches in series with a contactor coil. What happens if either switch opens?

The coil loses current because the rung has a single path through both switches.

What does permanent mean in permanent split capacitor (PSC) motor?

The run capacitor stays in the auxiliary winding circuit during both starting and normal running.

What determines the direction a conventional three-phase scroll compressor motor turns?

The phase sequence at its supply terminals determines the direction. Follow the equipment instructions to verify correct rotation at startup.

What makes an electronically commutated motor (ECM) electronically commutated?

Onboard electronics switch current through the windings in sequence. The electronics can also control motor speed and torque.

Which damper actuator can hold a commanded intermediate position?

A proportional or modulating actuator. A two-position actuator drives to one of two endpoints.

Where do the meter probes go when measuring voltage across a control coil?

One probe goes on each coil terminal so the meter reads their potential difference. Use the correct AC or DC setting and suitably rated equipment.

Why isolate one lead of a component before checking its resistance?

With power isolated and stored energy controlled, disconnecting one lead removes alternate current paths that can skew the component reading.

Why clamp an ammeter around just one conductor of a two-wire load circuit?

The outgoing and returning currents produce opposing magnetic fields. Clamping both together can make the load current read near zero.

Why use a true-RMS meter to measure distorted AC current?

Within its rated range and bandwidth, it calculates the waveform’s effective current. An average-responding meter calibrated for a sine wave can misread a distorted waveform.

Why check a multimeter’s CAT rating as well as its voltage rating?

The CAT rating identifies the measurement environment and its transient hazards. Choose a meter and leads rated for both the point in the system and the voltage.

What does 4 mA represent in a standard 4–20 mA signal loop?

It is the live zero, or 0% of the measurement span. A reading near 0 mA can indicate an open loop or loss of power.

Frequently Asked Questions

How many questions are on the NATE Core exam, and how much time do I get?

The Traditional Pathway Core exam has 50 questions and a 90-minute time limit. It is closed book.

What score do I need to pass the NATE Core exam?

NATE requires 70%, or at least 35 correct answers out of 50. NATE does not publish a Core candidate pass rate.

Can I take the NATE Core exam without employer sponsorship?

Yes. Schedule with a NATE Testing Organization or book a live online proctored session through NATE. NATE lists no formal education requirement and recommends formal training and about two years of experience for the Traditional Pathway.

Does passing the Core exam earn NATE certification?

The Traditional Pathway requires a pass on both Core and a specialty exam. If you pass Core before the specialty exam, NATE gives you two years of Core exam credit.

When can I retake the NATE Core exam after failing?

NATE allows a repeat attempt and provides a score report by topic after a failed exam. Its public materials do not specify a fixed waiting period or a separate waiting period after three failures. Confirm timing with NATE or your Testing Organization.

How are the flashcards divided among the Core exam topics?

The official outline maps to 13 Basic Electricity, 9 Safety, 7 Achieving Desired Conditions, 7 Taking Temperature & Humidity Measurements, 5 Tools, 5 Using Basic Science, and 4 Basic Construction cards.

Same family resources

Explore More NATE HVAC Certifications

Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.