Cheat sheet

Master Plumber Exam Cheat Sheet

Practice Questions

Administration and General Regulations

46%of exam

Plumbing Fixtures

14%of exam

Fixture LayoutWater Heater SafetyOccupancy CountsRelief Discharge

Water Supply and Distribution

11%of exam

Sanitary Drainage

11%of exam

Plumbing Vent Requirements

8%of exam

Traps, Interceptors, and Separators

8%of exam

Storm Drainage

2%of exam

Quick Facts

Exam owner
International Code Council
Program
National Contractor/Trades
G24-N
2018 IPC, 70% passing score
F24-N
2015 IPC, 70% passing score
T24-N reference
2021 International Plumbing Code
T24-N passing score
70% or 75%, by ID
F24-N Pearson registration ends
December 1, 2026
T24-N Pearson registration opens
December 1, 2026
Questions
100 multiple-choice
Time
4 hours
Format
Open-book Pearson VUE CBT
ICC exam fee
$120 per exam
Licensing
Confirm exam acceptance with jurisdiction

Code Lookup Order

Edition → topic → section → table → footnotes

G24-N uses 2018 IPCF24-N uses 2015 IPCT24-N uses 2021 IPCCheck exceptions before selecting value

Installation Lookup

  1. Code term changes the answer→Chapter 2 definitions(Check exact term first)
  2. Selecting pipe support spacing→Table 308.5(Material and orientation)
  3. Selecting underground drainage pipe→Table 702.2(Building drainage and vent)
  4. Testing plastic DWV→Water test §312.2(Air testing prohibited)
  5. Hydrotesting potable supply piping→Section 312.5(At least working pressure)
  6. Calculating required fixture counts→Table 403.1(Start with occupancy classification)

Exam Codes and Editions

G24-N
2018 IPC, 70% passing score
F24-N
2015 IPC, 70% passing scoreRegistration ends December 1, 2026
T24-N-70%
2021 IPC, 70% passing scoreOpens December 1, 2026
T24-N-75%
2021 IPC, 75% passing scoreOpens December 1, 2026
Exam pacing
Average 2.4 minutes per question

Plans and Measurements

Plan view
Horizontal routing from above
Riser diagram
Vertical routing and branch connections
Drawing legend
Decode line types and symbols
Pipe invert
Inside bottom of pipe
Developed length
Along pipe and fitting centerlinesCh. 2
Slope
Vertical fall ÷ horizontal run
40 ft at ¼ in/ft
10 in of fall
Flood level rim
Fixture edge where water overflowsCh. 2

Installation and Materials

Pipe and fitting sizes
Nominal unless specified§301.5
Material identification
Manufacturer marking and required standards§303
Foundation wall penetration
Relieving arch or oversized sleeve§305.3
Buried pipe
Continuous load-bearing bedding§306
Cutting and notching
Check structural safety provisions§307
Hanger spacing
Match material and orientationTable 308.5
Potable pipe materials
Separate service and distribution tablesTables 605.3–605.4
Drain and vent materials
Separate aboveground and underground tablesTables 702.1–702.2

Tests and Inspections

DWV
Drain, waste, and vent
DWV water test head
10 ft water head minimum§312.2
DWV head exception
Uppermost 10 ft of system§312.2
Successive DWV water tests
Overlap preceding section's upper 10 ft
DWV water test hold
At least 15 minutes
DWV air test
Nonplastic only, 5 psi, ≥15 min§312.3
Water supply hydrostatic test
At least working pressure≥15 min, §312.5
Water supply air test
Nonplastic only, ≥50 psi, ≥15 min§312.5
Supply test water
Use potable source§312.5
Test pressure ≤10 psi
Gauge increments ≤0.10 psi§312.1.1

Typical Toilet Clearances

15 side • 21 front • 30 center spacing

Inches under §405.3.130 between unpartitioned fixturesCheck accessibility exceptions

Fixture Layout

Minimum fixture counts
Occupancy and occupant loadTable 403.1
Toilet centerline to obstruction
15 in typical minimum§405.3.1
Unpartitioned adjacent toilet centers
30 in minimum spacing§405.3.1
Toilet front clearance
21 in typical minimum§405.3.1
Accessible fixtures
Check separate accessibility provisions§404
Accessible children's toilet exception
12 in minimum on one side2018/2021 §405.3.1
Flushed fixtures
Check tank or flushometer requirements2015 §425, 2018/2021 §415

Water Heater Safety

T&P relief valve
Temperature and pressure protection§504.4
Relief discharge path
Gravity flow with observable termination§504.6
Relief discharge outlet
Full-size, same-room air gap§504.6
Relief discharge piping
Dedicated, valve-free, trap-free line§504.6
Storage tank leakage hazard
Provide approved pan§504.7
Bottom-fed heater
Vacuum relief valve§504.2
Closed supply to storage heater
Cold-side expansion control downstream§607.3

Static and Residual Pressure

Static pressure

  • Measured with flow stopped
  • Building maximum §604.8

Residual pressure

  • Available while water flows
  • Fixture minimum Table 604.3

Identify the measurement condition

Water Supply Lookup

  1. Fixture needs minimum flow pressure→Table 604.3(Use pressure under flow)
  2. Source pressure cannot meet demand→Booster system §604.7(Check §606.5)
  3. Building static exceeds 80 psi→Regulator with strainer §604.8(Check service-line and riser exception)
  4. Selecting potable backflow protection→Table 608.1(Match hazard and pressure conditions)
  5. Check valve feeds storage heater→Expansion control §607.3(2015 specifies expansion tank)

Supply and Pressure

Fixture supply performance
Required flow and residual pressureTable 604.3
Variable street pressure
Design for minimum available pressure§604.6
Inadequate fixture flow pressure
Check booster system requirements§604.7
Building static pressure above 80 psi
Approved regulator with strainer§604.8
Regulated building pressure
80 psi static or lowerCheck §604.8 exception
Quick-closing valve
Water hammer arrestor§604.9
Water supply fixture units
Estimate probable supply demandAppendix E method
Elevated outlet
Deduct pressure for elevation rise≈0.433 psi/ft

Backpressure and Backsiphonage

Backpressure

  • Downstream pressure overcomes supply
  • Check protection for reversed pressure

Backsiphonage

  • Supply pressure falls below atmospheric
  • Check protection for suction

Match assembly to reversal modes

Backflow Protection

Cross-connection
Potential path for potable contamination
Backsiphonage
Reversal from supply-side negative pressure
Backpressure
Downstream pressure exceeds supply pressure
Potable outlet air gap
Clear space above flood rim
Pressure vacuum breaker
High/low hazard, backsiphonage onlyTable 608.1
Double-check assembly
Low hazard, both reversal modesTable 608.1
Reduced pressure principle assembly
High/low hazard, both reversal modesTable 608.1
Assembly selection
Check hazard and reversal modeTable 608.1

Fixture Unit Mapping

Supply units feed • Drainage units drain

Supply units estimate demandDrainage units size waste piping

Building Drain and Building Sewer

Building drain

  • Lowest piping collecting interior drainage
  • Extends 30 in beyond walls

Building sewer

  • Begins where building drain ends
  • Conveys discharge to disposal

Locate the junction cleanout

Drainage Lookup

  1. Sizing sanitary building sewer→Table 710.1(1)(DFUs and pipe slope)
  2. Sizing fixture branch or stack→Table 710.1(2)(Read applicable load column)
  3. Sanitary discharge cannot drain by gravity→Check sump and pump §712(Verify gravity route and exceptions)
  4. Fixture floor below upstream cover→Check backwater valve rule(Next upstream public sewer manhole)
  5. Draining commercial food-preparation equipment→Indirect waste air gap(Start at §802.1.1)
  6. Sizing a horizontal storm drain→Table 1106.2(Use flow and slope)

Gravity Drainage

Drainage fixture units (DFU)
Relative sanitary discharge loadTable 709.1
Building drain or sewer sizing
Sum DFUs, select slope columnTable 710.1(1)
Fixture branches and stacks
Use branch or stack columnTable 710.1(2)
Horizontal drain ≤2½ in
¼ in per ft minimumTable 704.1
Horizontal drain 3–6 in
⅛ in per ft baselineTable 704.1
Horizontal drain ≥8 in
¹⁄₁₆ in per ft baselineTable 704.1
Upstream of grease interceptor
¼ in per ft minimum2018/2021 §704.1
Drain-to-sewer junction cleanout
At junction or ≤10 ft upstream§708.1.3
Drainage fitting selection
Match pattern to flow directionTable 706.3

Air Gap and Air Break

Indirect waste air gap

  • Outlet clears receptor flood rim
  • ≥2× effective waste opening

Indirect waste air break

  • Outlet clears receptor trap seal
  • Use where expressly permitted

Use the required receptor separation

Indirect Waste and Pumps

Commercial food preparation fixtures
Indirect waste through air gap§802.1.1
Indirect discharge installation
Check receptor, trap, and vent2015 §802.2, 2018/2021 §802.3
Drainage air gap
≥2× effective opening above rim
Drainage air break
Outlet above receptor trap seal
Below gravity sewer elevation
Covered, vented sump with pump§712.1
Sump pump discharge
Check valve then accessible shutoff§712.2
Backwater valve trigger
Floor below next upstream manholePublic sewer cover elevation
Backwater valve section
2015 §715.1, 2018/2021 §714.1

Horizontal Wet Vent Limits

Two bathroom groups, one floor

Connect fixture drains independentlyOther fixtures join downstreamConfirm §912 sizing

Dry Vent and Wet Vent

Dry vent

  • Carries air
  • Check §905 connections and grade

Wet vent

  • Carries drainage and air
  • Check §912 fixture groups

Trace drainage before choosing vent

Vent Lookup

  1. Finding trap-to-vent limit→Table 909.1(Trap size and slope)
  2. Dry vent joins horizontal drain→Section 905.3(Connect above drain centerline)
  3. Two bathroom groups share level→Check wet vent §912(Verify fixture and connection limits)
  4. Considering an air admittance valve→Section 918(Check access and outdoor vent)
  5. Locating roof vent termination→Section 903(Check jurisdiction-specified roof height)

Vent Layout and Sizing

Drainage vent
Admits or releases air
Trap-to-vent distance
Measure from weir along drainTable 909.1
Trap arm at ¼ in/ft
1½ in: 6 ft maximumTable 909.1
Self-siphoning fixtures
Trap-to-vent developed-length exception§909.1
Dry vent on horizontal drain
Connect above drain centerline§905.3
Dry vent before horizontal offset
Rise ≥6 in above rimHighest trapped fixture served
Horizontal wet vent
Up to two same-floor bathroom groups§912.1
Vent terminals
Check openings, roof use, frost§903
Air admittance valve (AAV)
Admits air under negative pressure§918
Systems using air admittance valves
At least one outdoor stack ventOr outdoor vent stack §918.7

Trap and Grease Interceptor

Fixture trap

  • Liquid seal blocks sewer gas
  • Check seal depth and protection

Grease interceptor

  • Captures grease-bearing waste constituents
  • Allow access for service

Identify the function first

Trap and Interceptor Lookup

  1. Trap seal subject to evaporation→Seal protection §1002.4.1(Check permitted primer or barrier)
  2. Food-prep fixture drains grease→Grease interceptor or removal device(Check §1003.3.1)
  3. Repair garage drains oily waste→Oil separator §1003.4(Check covered discharge and exceptions)
  4. Food waste disposer joins interceptor→Check edition §1003.3.2(2018/2021 prohibit grease interceptor connection)

Trap Seals and Separation

Fixture trap
Liquid seal blocks sewer gas§1002
Typical fixture trap seal
2–4 in liquid depth§1002.4
Special accessible fixture designs
Deeper trap seals permitted§1002.4
Emergency floor drain seal
Protect against seal loss§1002.4.1
Potable-water trap primer
Replenishes trap waterASSE 1018
Barrier-type seal protection
Limits floor drain seal evaporationASSE 1072
Grease interceptor
Retains fats, oils, and grease§1003.3
Oil separator
Separates oils from covered discharges§1003.4
Interceptor service
Provide access for maintenance§1003

Primary and Secondary Roof Drainage

Primary

  • Carries design roof runoff
  • Size by design flow

Secondary

  • Handles blocked primary drainage
  • Separate visible discharge endpoint

Size overflow independently

Roof and Storm Drainage

Stormwater disposal
Route to approved disposal§1101.2
Design rainfall
100-year hourly or approved local rate§1106.1
Vertical wall draining onto roof
Add half the wall area§1106.4
Roof drain design flow
Published flow at ponding head§1105.2
Horizontal storm pipe sizing
Match design flow and slopeTable 1106.2
Required roof drains, entrapment possible
Provide overflow drain or scupper§1108.1
Secondary system outlet
Separate, visible above-grade discharge§1108.2
Secondary system sizing
Assume primary flow is zero§1108.3

Common Traps

Code editions

G24-N uses 2018 IPC ≠ F24-N uses 2015 IPC

Book policy

Approved IPC is exam reference ≠ Cheat sheet is pre-exam review

Plastic pipe testing

DWV water test covers plastic ≠ DWV air test excludes plastic

Nonplastic air test pressures

DWV air test 5 psi ≠ Water supply air test ≥50 psi

Reversal targets

Backflow protection safeguards potable supply ≠ Backwater valve stops sewer backup

Sizing inputs

Sanitary drainage uses DFUs ≠ Storm drainage uses runoff flow

Trap seal loss

Venting limits pressure disturbances ≠ Seal protection addresses evaporation

Disposer to grease interceptor

2015 allows connection after solids interception ≠ 2018/2021 prohibit this connection

Two drainage destinations

Stormwater needs approved disposal ≠ Sewage-only sewers exclude stormwater

Last Minute

  1. 1.Match registration to IPC edition
  2. 2.Confirm jurisdiction accepts exam ID
  3. 3.DWV water test hold ≥15 minutes
  4. 4.Toilet front clearance typically 21 in
  5. 5.Check regulator above 80 psi static
  6. 6.Size sanitary drains by fixture units
  7. 7.Trap-to-vent limits use Table 909.1
  8. 8.Typical trap seal depth 2–4 in
  9. 9.Apply table footnotes before choosing
  10. 10.Keep overflow discharge separate and visible
Same family resources

Explore More Plumber License

Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.