Free Practice Questions for IN Plumber

Exam-style questions and explanations by OpenExamPrep.

✓ No registration✓ No credit card
328+ Questions
100% Free
Exam Review

Key Facts: IN Plumber Exam

Pass/Fail

Scoring

Prov CIB (cut score not published)

90

Questions

3 hours limit

$75

Exam Fee

Prov, Inc.

2006 IPC

Code Base

675 IAC 16-1.4

Indiana's journeyman plumber exam is administered by Prov, Inc. for the Indiana Professional Licensing Agency (PLA). The test consists of 90 open-book multiple-choice questions in 3 hours; Prov scores it pass/fail against an undisclosed cut score and does not publish a passing percentage. Content is based on the 2006 International Plumbing Code, 2nd printing, Indiana Edition, the 2012 Indiana Amendments (675 IAC 16-1.4), and a compilation of the Indiana Code and Indiana Administrative Code (IC 25-28.5 / 860 IAC).

Sample IN Plumber Practice Questions

Try these sample questions to review concepts for the IN Plumber exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 328+ question experience with AI tutoring.

1Under the IPC as adopted by Indiana, what is the minimum size of a building sewer?
A.2 inches
B.3 inches
C.4 inches
D.6 inches
Explanation: Per IPC building sewer requirements, the minimum size is 3 inches under the IPC. This ensures adequate capacity for the building drainage load and allows for proper maintenance access.
2Per the IPC as adopted by Indiana, what is the minimum slope for a 4-inch horizontal drainage pipe?
A.1/16 inch per foot
B.1/8 inch per foot
C.1/4 inch per foot
D.1/2 inch per foot
Explanation: Per IPC drainage slope tables, horizontal drainage pipes 3 inches and larger require a minimum slope of 1/8 inch per foot. This ensures adequate velocity (approximately 2 fps) to transport solids through the drainage system.
3What is the DFU value for a residential water closet (1.6 gpf) under the IPC?
A.2 DFU
B.3 DFU
C.4 DFU
D.6 DFU
Explanation: Per IPC fixture unit tables, a residential water closet with 1.6 gpf is rated at 3 DFU. This value is used for drainage and vent pipe sizing calculations throughout the plumbing system.
4Per the IPC as adopted by Indiana, what is the maximum distance between cleanouts on a horizontal drainage pipe?
A.50 feet
B.75 feet
C.100 feet
D.150 feet
Explanation: Per IPC cleanout requirements, cleanouts must be installed at intervals not exceeding 100 feet on horizontal drainage lines. Proper cleanout spacing ensures the entire system can be maintained and cleared of blockages.
5Under Indiana regulations, what type of backflow preventer is required for a high-hazard cross-connection?
A.Atmospheric vacuum breaker (AVB)
B.Pressure vacuum breaker (PVB)
C.Double check valve assembly (DCVA)
D.Reduced pressure zone (RPZ) assembly
Explanation: Per IPC backflow prevention requirements, a reduced pressure zone (RPZ) assembly is required for high-hazard cross-connections. The RPZ provides the highest level of protection with a relief valve between two check valves.
6Per the IPC as adopted by Indiana, what is the minimum water supply pipe size for a bathtub with shower?
A.3/8 inch
B.1/2 inch
C.3/4 inch
D.1 inch
Explanation: Per IPC fixture supply sizing tables, the minimum supply pipe size for a bathtub with shower is 1/2 inch. This ensures adequate flow and pressure at the fixture for proper operation.
7What is the maximum water temperature setting for a residential water heater per the IPC?
A.110°F
B.120°F
C.140°F
D.180°F
Explanation: Per IPC hot water requirements, the maximum delivery temperature at residential fixtures is 120°F. Anti-scald devices or thermostatic mixing valves must limit output temperature to prevent burns.
8Per the IPC as adopted by Indiana, what is the minimum trap seal depth for a standard plumbing fixture?
A.1 inch
B.2 inches
C.3 inches
D.4 inches
Explanation: Per IPC trap requirements, the minimum trap seal depth is 2 inches and the maximum is 4 inches. The water seal prevents sewer gases from entering the building through fixture drains.
9Under the IPC as adopted by Indiana, what is the minimum vent pipe size?
A.3/4 inch
B.1 inch
C.1-1/4 inches
D.1-1/2 inches
Explanation: Per IPC venting requirements, the minimum vent pipe size is 1-1/4 inches. No vent pipe shall be less than 1-1/4 inches in diameter. The vent must also be at least one-half the diameter of the drain it serves.
10Per the IPC as adopted by Indiana, what is the maximum static water pressure in a building distribution system?
A.60 psi
B.80 psi
C.100 psi
D.125 psi
Explanation: Per IPC water pressure requirements, water pressure shall not exceed 80 psi static. Where pressures exceed 80 psi, a pressure-reducing valve must be installed to prevent fixture damage and pipe noise.

About the IN Plumber Exam

Indiana journeyman plumber exam administered by Prov under the Indiana Plumbing Commission (PLA). Based on the 2006 International Plumbing Code, 2nd printing, Indiana Edition with the 2012 Indiana Amendments (675 IAC 16-1.4). 90 open-book multiple-choice questions with a 3-hour time limit.

Exam sponsor: Indiana Professional Licensing Agency (PLA) / Prov, Inc.. The requirements and fees below concern the certification or admission exam, separate from our free practice resources.

Questions

90 questions

Time Limit

3 hours

Passing Score

Not published; Prov reports pass/fail against an undisclosed cut score

Exam / Certification Fees

$75 exam fee + $30 PLA application fee

Exam sponsor website

Reported exam pass rate: Not published by the Indiana Plumbing Commission or Prov. Exam sponsor website

Fees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.

Our practice resources: topics covered

We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.

17 of 90 questions

Vents

Vent sizing, developed lengths, terminals, wet venting, circuit venting, and AAVs

15 of 90 questions

Sanitary Drainage

Drain sizing, DFU calculations, slope requirements, cleanouts, and sumps

14 of 90 questions

Water Supply and Distribution

WSFU sizing, backflow prevention, pressure regulation, and piping materials

10 of 90 questions

Fixtures

Fixture setting and clearances, minimum facilities, flushometer valves, traps, and interceptors

8 of 90 questions

Developed Length/Isometric Analysis

Isometric drawing interpretation, riser diagrams, and 45-degree offset calculations

7 of 90 questions

General Requirements

Piping protection, hanger spacing, structural notching and boring limits

7 of 90 questions

Water Heaters

Water heater sizing, T&P relief valves, discharge piping, and combustion air

6 of 90 questions

Storm Water Systems

Rainfall rates, roof drain sizing, vertical conductors, and horizontal storm drains

6 of 90 questions

Indiana Business

Plumbing Commission statutes (IC 25-28.5), rules (860 IAC), permits, and safety

Preparing for the IN Plumber Exam

What You Need to Know

  • Passing score: Not published; Prov reports pass/fail against an undisclosed cut score
  • Exam length: 90 questions
  • Time limit: 3 hours
  • Exam / certification fees: $75 exam fee + $30 PLA application fee Official sources

Using Our Practice Resources

  • Work through all 328 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

IN Plumber: Suggested Study Strategy

1Master IPC drainage fixture unit (DFU) values and pipe sizing tables
2Study backflow prevention device selection and cross-connection control
3Memorize minimum pipe sizes, slopes, and clearances for common fixtures
4Practice isometric riser diagram analysis and 45-degree offset calculations
5Understand wet venting and circuit venting provisions in the IPC
6Learn Indiana-specific amendments in 675 IAC 16-1.4 and PLA licensing rules

Frequently Asked Questions

What plumbing code is tested on the Indiana Journeyman Plumber exam?

The Indiana Journeyman Plumber examination tests the 2006 International Plumbing Code (Indiana Edition) incorporating the 2012 Indiana Amendments (675 IAC 16-1.4), alongside Indiana statutes (IC 25-28.5) and Plumbing Commission rules (860 IAC).

Who administers the Indiana plumber exam?

The exam is developed and administered by Prov, Inc. under contract with the Indiana Plumbing Commission within the Indiana Professional Licensing Agency (PLA).

How many questions are on the Indiana plumber exam and what is the passing score?

The Indiana Journeyman Plumber exam consists of 90 multiple-choice questions with a 3-hour (180-minute) time limit. Prov grades it immediately and reports pass or fail; the cut score is not published, and passing candidates receive no numerical grade.

Is the Indiana Journeyman Plumber exam open book?

Yes. The examination is open book. Candidates may bring approved reference books specified in the Prov Candidate Information Bulletin, including the 2006 IPC (Indiana Edition) and 2012 Indiana Amendments.