Free Practice Questions for IN Plumber

Exam-style questions and explanations by OpenExamPrep.

✓ No registration✓ No credit card
Exam pass rate: ~50-60%
328+ Questions
100% Free

Loading practice questions...

Exam Review

Key Facts: IN Plumber Exam

70%

Passing Score

Indiana Professional Licensing Agency (PLA)

90

Questions

3 hours limit

$30-100

Exam Fee

Prov (formerly PSI)

IPC

Code Base

Indiana adoption

Indiana's journeyman plumber exam is based on the IPC and administered by Prov (formerly PSI). Indiana uses the IPC with state amendments. The exam is administered by Prov (formerly PSI). Indiana has one of the lowest exam fees in the country. The exam requires 70% to pass and tests drainage, water supply, venting, gas piping, and fixture knowledge.

Sample IN Plumber Practice Questions

Try these sample questions to review concepts for the IN Plumber exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 328+ question experience with AI tutoring.

1Under the IPC as adopted by Indiana, what is the minimum size of a building sewer?
A.2 inches
B.3 inches
C.4 inches
D.6 inches
Explanation: Per IPC building sewer requirements, the minimum size is 3 inches under the IPC. This ensures adequate capacity for the building drainage load and allows for proper maintenance access.
2Per the IPC as adopted by Indiana, what is the minimum slope for a 4-inch horizontal drainage pipe?
A.1/16 inch per foot
B.1/8 inch per foot
C.1/4 inch per foot
D.1/2 inch per foot
Explanation: Per IPC drainage slope tables, horizontal drainage pipes 3 inches and larger require a minimum slope of 1/8 inch per foot. This ensures adequate velocity (approximately 2 fps) to transport solids through the drainage system.
3What is the DFU value for a residential water closet (1.6 gpf) under the IPC?
A.2 DFU
B.3 DFU
C.4 DFU
D.6 DFU
Explanation: Per IPC fixture unit tables, a residential water closet with 1.6 gpf is rated at 3 DFU. This value is used for drainage and vent pipe sizing calculations throughout the plumbing system.
4Per the IPC as adopted by Indiana, what is the maximum distance between cleanouts on a horizontal drainage pipe?
A.50 feet
B.75 feet
C.100 feet
D.150 feet
Explanation: Per IPC cleanout requirements, cleanouts must be installed at intervals not exceeding 100 feet on horizontal drainage lines. Proper cleanout spacing ensures the entire system can be maintained and cleared of blockages.
5Under Indiana regulations, what type of backflow preventer is required for a high-hazard cross-connection?
A.Atmospheric vacuum breaker (AVB)
B.Pressure vacuum breaker (PVB)
C.Double check valve assembly (DCVA)
D.Reduced pressure zone (RPZ) assembly
Explanation: Per IPC backflow prevention requirements, a reduced pressure zone (RPZ) assembly is required for high-hazard cross-connections. The RPZ provides the highest level of protection with a relief valve between two check valves.
6Per the IPC as adopted by Indiana, what is the minimum water supply pipe size for a bathtub with shower?
A.3/8 inch
B.1/2 inch
C.3/4 inch
D.1 inch
Explanation: Per IPC fixture supply sizing tables, the minimum supply pipe size for a bathtub with shower is 1/2 inch. This ensures adequate flow and pressure at the fixture for proper operation.
7What is the maximum water temperature setting for a residential water heater per the IPC?
A.110°F
B.120°F
C.140°F
D.180°F
Explanation: Per IPC hot water requirements, the maximum delivery temperature at residential fixtures is 120°F. Anti-scald devices or thermostatic mixing valves must limit output temperature to prevent burns.
8Per the IPC as adopted by Indiana, what is the minimum trap seal depth for a standard plumbing fixture?
A.1 inch
B.2 inches
C.3 inches
D.4 inches
Explanation: Per IPC trap requirements, the minimum trap seal depth is 2 inches and the maximum is 4 inches. The water seal prevents sewer gases from entering the building through fixture drains.
9Under the IPC as adopted by Indiana, what is the minimum vent pipe size?
A.3/4 inch
B.1 inch
C.1-1/4 inches
D.1-1/2 inches
Explanation: Per IPC venting requirements, the minimum vent pipe size is 1-1/4 inches. No vent pipe shall be less than 1-1/4 inches in diameter. The vent must also be at least one-half the diameter of the drain it serves.
10Per the IPC as adopted by Indiana, what is the maximum static water pressure in a building distribution system?
A.60 psi
B.80 psi
C.100 psi
D.125 psi
Explanation: Per IPC water pressure requirements, water pressure shall not exceed 80 psi static. Where pressures exceed 80 psi, a pressure-reducing valve must be installed to prevent fixture damage and pipe noise.

About the IN Plumber Exam

Indiana journeyman plumber exam administered by Prov under the Professional Licensing Agency. Based on the International Plumbing Code (IPC). 80-100 multiple-choice questions with a 3-hour time limit requiring 70% to pass.

Exam sponsor: Indiana Professional Licensing Agency (PLA). The requirements and fees below concern the certification or admission exam, separate from our free practice resources.

Questions

90 questions

Time Limit

3 hours

Passing Score

70%

Exam / Certification Fees

$30-100

Exam sponsor website

Reported exam pass rate: ~50-60%. This describes exam candidates, not OpenExamPrep users or results from using our resources. Exam sponsor website

Fees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.

Our practice resources: topics covered

We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.

25%

Drainage & Waste Systems

Drain sizing, DFU calculations, slope requirements, cleanouts per IPC

20%

Water Supply & Distribution

Pipe sizing, backflow prevention, water heaters, pressure regulation per IPC

20%

Venting Systems

Vent sizing, wet venting, AAVs, vent termination, circuit venting per IPC

15%

Gas Piping

Gas pipe sizing, appliance venting, pressure testing, BTU calculations per IFGC

20%

Fixtures, Materials & Indiana Code

Fixture installation, materials, joints, permits, inspections, and Indiana-specific requirements

Preparing for the IN Plumber Exam

What You Need to Know

  • Passing score: 70%
  • Exam length: 90 questions
  • Time limit: 3 hours
  • Exam / certification fees: $30-100 Official sources

Using Our Practice Resources

  • Work through all 328 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

IN Plumber: Suggested Study Strategy

1Master IPC drainage fixture unit (DFU) values and pipe sizing tables
2Study backflow prevention device selection and cross-connection control
3Memorize minimum pipe sizes, slopes, and clearances for common fixtures
4Practice gas pipe sizing calculations using IFGC tables
5Understand wet venting and circuit venting provisions in the IPC
6Learn Indiana-specific permit and inspection requirements

Frequently Asked Questions

What code does Indiana use for the plumber exam?

Indiana uses the IPC. The exam covers drainage, venting, water supply, gas piping, and fixture requirements as adopted by the state.

Who administers the Indiana plumber exam?

The exam is administered by Prov (formerly PSI) under the Indiana Professional Licensing Agency (PLA).

How many questions are on the Indiana plumber exam?

The Indiana plumber exam has approximately 90 questions with a 3 hours time limit. A score of 70% is required to pass.

Is the IN plumber exam open book?

Most Prov (formerly PSI)-administered plumber exams allow a bound copy of the adopted code. Check with the Indiana Professional Licensing Agency (PLA) for approved reference materials.