1.2 Navigating the 2006 IPC & 2012 Indiana Amendments

Key Takeaways

  • The Indiana Plumbing Code is the 2006 International Plumbing Code as amended and adopted by the Fire Prevention and Building Safety Commission at 675 IAC 16-1.4, titled the 2012 Indiana Plumbing Code.
  • Indiana deletes model IPC Chapter 1 and substitutes its own Sections 101.1 through 101.9, which route administration, plan review and appeals to the General Administrative Rules at 675 IAC 12 and state at 101.2 that the plumbing code does not regulate plumber licensure, which lives in IC 25-28.5.
  • Indiana Section 101.3 makes appendix provisions unenforceable unless specifically adopted: Appendix C (gray water) and Appendix E (water pipe sizing) are adopted, while Appendices A, B, D, F and G are not.
  • Mastering table lookups such as Table 709.1 for DFU values, Table 710.1(1) and 710.1(2) for drainage sizing, Table 906.1 for trap-to-vent distance, and Table 916.1 for vent sizing is essential for exam pacing.
  • Indiana deleted IPC Section 403 and Section 404 outright and inserted 'See Chapter 29 of the Indiana Building Code,' so minimum-fixture-count questions are answered from the building code, not the plumbing code.
Last updated: September 2026

1.2 Navigating the 2006 IPC & 2012 Indiana Amendments

Core Principle: In Indiana, plumbing installations are governed by a dual-tier code framework. The base model code is the 2006 International Plumbing Code (IPC) published by the International Code Council (ICC). However, the model code is legally enforced only as amended and adopted by the Indiana Fire Prevention and Building Safety Commission (FPBSC) under Title 675, Article 16, Rule 1.4 of the Indiana Administrative Code (675 IAC 16-1.4), known as the 2012 Indiana Plumbing Code.


The Dual-Layer Architecture of Indiana Plumbing Law

To succeed on the Indiana Journeyman Plumber exam, candidates must understand how model code language interacts with state-specific administrative amendments. A common error made by test-takers is reading a section directly out of the standard model IPC without verifying whether Indiana has amended, rewritten, or completely deleted that section in 675 IAC 16-1.4.

+-------------------------------------------------------------------------+
|                 INDIANA PLUMBING CODE HIERARCHY                         |
+-------------------------------------------------------------------------+
| 1. Indiana Statutes (IC 25-28.5 & IC 22-12/13/15) - Legislative Law    |
|       |                                                                 |
|       v                                                                 |
| 2. 675 IAC 16-1.4 (2012 Indiana Amendments) - State Administrative Rule |
|       |   (Deletes, modifies, or adds sections to the model code)       |
|       v                                                                 |
| 3. 2006 International Plumbing Code (IPC) - Base Model Code             |
|           (Applies only where NOT modified by 675 IAC 16-1.4)           |
+-------------------------------------------------------------------------+

When a conflict arises between the text of the model 2006 IPC and 675 IAC 16-1.4, the Indiana amendment always takes legal precedence. If the Indiana amendment deletes a section, that section is entirely void in Indiana.


Chapter-by-Chapter Technical Breakdown of the 2006 IPC

The 2006 IPC is structured logically, tracking the path of water into a building and the discharge of wastewater and storm drainage out of the building. Becoming intimately familiar with each chapter's scope enables rapid section targeting during the exam.

Chapter 1: Administration

  • Model Scope: Duties of code officials, permits, plan review, fees, and violations.
  • Indiana Impact: 675 IAC 16-1.4-2 deletes model Chapter 1 and inserts a short Indiana Chapter 1 in its place (Sections 101.1 through 101.9). The Indiana text does the real administrative work by reference: plans go to 675 IAC 12-6, existing construction and code conflicts to 675 IAC 12-4, alternative methods to 675 IAC 12-6-11, and appeals to IC 4-21.5 and IC 22-12-7.
  • Two Indiana Chapter 1 facts worth tabbing: 101.2 says the code "does not regulate licensure requirements for plumbers. Such licensure requirements are set out in IC 25-28.5." 101.3 says "Provisions in the appendices are not enforceable unless specifically adopted."

Which Appendices Actually Count in Indiana

Because of Section 101.3, appendix questions are a classic trap. 675 IAC 16-1.4 resolves each appendix explicitly:

AppendixSubjectIndiana Status
APlumbing Permit Fee ScheduleText deleted; "See local ordinance"
BRates of Rainfall for Various CitiesNot adopted, informational only
CGray Water Recycling SystemsAdopted (gray water redefined; Section C103 deleted)
DDegree Day and Design TemperaturesNot adopted, informational only
ESizing of Water Piping SystemAdopted (two cross-reference corrections in E201.1)
FStructural SafetyNot adopted; for cutting, notching and boring in wood members see the Indiana Building Code (675 IAC 13) or Indiana Residential Code (675 IAC 14)
GVacuum Drainage SystemNot adopted, informational only

Appendix E being adopted matters: it is the enforceable water-pipe-sizing method, and Table E103.3(2) is where water supply fixture unit (WSFU) values live. Appendix B being informational matters too: storm sizing starts from Figure 1106.1 (100-year, 1-hour rainfall), not from an appendix city list.

Chapter 2: Definitions

  • Model Scope: Crucial engineering and legal definitions.
  • Exam Strategy: Never guess at technical terminology. Look up terms such as Air Gap (Drainage), Air Gap (Water Distribution), Branch Interval, Cleanout, Developed Length, Drainage Fixture Unit (DFU), Invert, Stack Vent, Vent Stack, and Water Supply Fixture Unit (WSFU) in Chapter 2.

Chapter 3: General Regulations

  • Model Scope: General installation standards, protection of piping against physical damage and corrosion, trenching and backfilling, piping sleeving through concrete walls, structural safety (drilling and notching joists and studs), and pipe hanger spacing.
  • Key Tables: Table 308.5 (Hanger Spacing — maximum horizontal and vertical support intervals by piping material).
  • Indiana Impact: 675 IAC 16-1.4-4 rewrites 305.6.1 (waterlines) and adds 305.6.2 with Table 305.6.2, a county-by-county minimum bury depth for exterior water supply piping (36, 42 or 48 inches). It also adds "No plumbing pipes shall be directly embedded in concrete or masonry" to 305.3, changes the shield-plate thickness in 305.8 to 0.0575 inch (No. 16 gage), and deletes Sections 308.6 and 311 entirely.

Chapter 4: Fixtures, Faucets, and Fixture Fittings

  • Model Scope: Quality and design of plumbing fixtures, clearances from walls and partitions, accessible fixture standards, urinal partitions, and maximum water consumption flow rates.
  • Indiana Impact: 675 IAC 16-1.4-5 deletes Sections 403 and 404 in their entirety and inserts "See Chapter 29 of the Indiana Building Code." Sections 405.2, 405.3, 405.3.1, 410.1 and 410.2 get the same treatment, and the last sentence of 419.2 does too. So minimum fixture counts, accessible facilities, water closet clearances and drinking-fountain rules are answered out of IBC/Indiana Building Code Chapter 29, not the plumbing code. Indiana also adds ASME A112.19.19 (vitreous china nonwater urinals) to Section 419.1 and adds a backflow requirement to Section 413.4 for food waste grinders.
  • What still lives in Chapter 4: the fixture rules in Sections 407 (lavatories), 416 (tempered water for public hand washing), 417 (showers), 419 (urinals), 424 (faucets and valves) and 425 (flushing devices). Note that the maximum-flow table, Table 604.4, is a Chapter 6 table, not a Chapter 4 table.

Chapter 5: Water Heaters

  • Model Scope: Water heater design, pressure relief valves, temperature and pressure (T&P) relief valve discharge piping standards, drip pans, elevation of ignition sources in residential garages (minimum 18 inches above floor), and combustion air requirements.
  • Key Code Sections: Section 504.5 (relief valve setting: not more than 210°F and not exceeding the rated working pressure or 150 psi, whichever is less), Section 504.6 (T&P discharge piping), Section 504.7.1/504.7.2 (pan and pan drain).
  • Indiana Impact: 675 IAC 16-1.4-6 adds Section 502.1.1 (ignition sources elevated not less than eighteen (18) inches above the floor in garages and hazardous locations), adds 502.1.1.1 (parking-garage vestibule rule), adds 502.2.1 (fuel-fired appliances prohibited in sleeping rooms, bathrooms, toilet rooms, storage closets and surgical rooms), rewrites 504.2 (bottom fed water heaters) and adds 504.2.1 (cold water piping must rise above the top of the water heater before connecting to the tank inlet).

Chapter 6: Water Supply and Distribution

  • Model Scope: Water service pipe sizing, water distribution pipe materials, maximum allowable working pressures (80 psi maximum static pressure before requiring a pressure-reducing valve), water hammer arrestors, and backflow prevention.
  • Key Sections & Tables: Table 605.3 (Water Service Pipe Materials), Table 605.4 (Water Distribution Pipe Materials), Table 604.3 (required flow rate and flow pressure at fixture outlets), Table 604.5 (minimum fixture supply sizes), and Section 608 (Protection of Potable Water Supply and Backflow Devices).
  • Indiana Impact: 675 IAC 16-1.4-7 strikes "M or WM" from the copper entry in Table 605.3, so Type M copper is not an approved water service material in Indiana. It also rewrites 608.14.1 (12-inch clearance below the assembly; permanent platform above 5 feet; RPZ mounted horizontally), rewrites 608.15.4 (AVB critical level 6 inches above the flood level rim, PVB 12 inches above all downstream piping), adds 608.1.1 (assembly tested at installation and after relocation) and 608.1.2 (listed assemblies for hot water above 110°F), and reclassifies carbonated beverage machines in Table 608.1 as high hazard.

Chapter 7: Sanitary Drainage

  • Model Scope: Drainage piping materials, minimum pipe slopes, sizing soil and waste stacks, building drain sizing, building sewer sizing, cleanout locations and clearances, sumps and ejectors, and backwater valves.
  • Key Tables:
    • Table 704.1 (minimum slope of horizontal drainage pipe)
    • Table 706.3 (fittings permitted for each change in direction)
    • Table 709.1 (Drainage Fixture Unit values for individual fixtures and groups)
    • Table 709.2 (DFU values for unlisted fixtures, by trap size)
    • Table 710.1(1) (Building Drain and Sewer Sizing based on slope and DFU load)
    • Table 710.1(2) (Horizontal Fixture Branch and Stack Sizing)
  • Indiana Impact: 675 IAC 16-1.4-8 adds Section 710.3, setting a 2-inch nominal minimum for any sanitary drainage pipe installed underground within a building, amends Table 710.1(2) (2,900 becomes 3,900), strikes "M or DWV" from the copper entry in Table 702.2, strikes "side inlets or" from Section 706.3, and deletes the fourth sentence of Section 708.3.5.

Chapter 8: Indirect and Special Waste

  • Model Scope: Indirect waste piping, air gaps versus air breaks, commercial food preparation sinks, dishwashers, ice machines, sterile healthcare equipment, and chemical waste neutralization.
  • Key Sections: Section 802.1 (Where indirect waste is required) and Section 802.2 (Air gaps vs. air breaks).

Chapter 9: Vents

  • Model Scope: Vent sizing, stack vents, vent stacks, individual venting, common venting, wet venting, circuit venting, combination waste and vent systems, island fixture vents, and vent terminals through roofs.
  • Key Tables & Sections:
    • Table 906.1 (Distance of Fixture Trap from Vent)
    • Table 908.3 (Common Vent Sizes)
    • Table 909.3 (Wet Vent Size by DFU load)
    • Table 910.4 (Waste Stack Vent Size)
    • Table 912.3 (Size of Combination Drain and Vent Pipe)
    • Table 916.1 (Size and Developed Length of Stack Vents and Vent Stacks) and Table 916.5.1 (Size and Length of Sump Vents)
    • Section 917 (Air Admittance Valves)
  • Indiana Impact: 675 IAC 16-1.4-10 fills the blank in 904.1 with six (6) inches, adds a floor drain exception to 901.2.1, deletes the stack-type AAV reference to ASSE 1050 from 917.1, rewrites 917.3.3 so that AAVs shall not serve as the vent terminal for vent stacks or stack vents, strikes the stack-type AAV location sentence from 917.4, and adds to 917.8 that AAVs shall not be used to vent sump pits.

Chapter 10: Traps, Interceptors, and Separators

  • Model Scope: Trap seals (minimum 2-inch, maximum 4-inch liquid seal), trap primers, prohibited traps (bell traps, crown-vented traps, full S-traps, running traps without vents), grease interceptors, oil-water separators, and sand interceptors.
  • Key Sections: Section 1002.3 (prohibited traps), Section 1002.4 (trap seal depth and primers), Section 1003 (interceptors and separators) with Table 1003.3.4.1 (grease interceptor capacity).
  • Indiana Impact: 675 IAC 16-1.4-11 amends 1002.1 exception 2 to allow a combination fixture "up to three (3) compartments" on one trap, and adds to 1003.1 that a cleanout shall be installed immediately downstream of the interceptor or separator.

Chapter 11: Storm Drainage

  • Model Scope: Sizing roof drains, vertical conductors (leaders), horizontal storm drains, secondary (emergency) overflow roof drains, and subsoil drainage sumps.
  • Key Tables: Figure 1106.1 (100-year, 1-hour rainfall rate), Table 1106.2 (Size of Vertical Conductors and Leaders), Table 1106.3 (Size of Horizontal Storm Drainage Piping), Table 1106.6 (Size of Semicircular Roof Gutters), and Table 1102.4 (Building Storm Sewer Pipe Materials).
  • Indiana Impact: 675 IAC 16-1.4-12 deletes Section 1107.2 without substitution and adds Section 1113.1.5, requiring water-powered sump pumps to comply with Section 608.

Key Indiana Amendments in 675 IAC 16-1.4

The table below highlights the most significant Indiana state amendments that candidates encounter on the examination:

2006 IPC SectionSubject MatterIndiana Amendment Action (675 IAC 16-1.4)Practical Exam Consequence
Chapter 1Scope and AdministrationDeleted and replaced with Indiana Sections 101.1–101.9Permits, plan review, variances and appeals run through 675 IAC 12; licensure is in IC 25-28.5.
Section 305.3Stress and StrainThird sentence added"No plumbing pipes shall be directly embedded in concrete or masonry."
Section 305.6.1 / new 305.6.2Waterline freezing; bury depthRewritten, plus a new section and Table 305.6.2Exterior water supply piping must be buried to a county-specific depth of 36, 42 or 48 inches measured from finished grade to the top of the pipe. No waterlines concealed in outside walls above grade.
Section 305.8Protective shield platesAmendedPlate thickness becomes 0.0575 inch (No. 16 gage) steel, replacing the model 0.062 inch.
Sections 308.6 and 311Sway bracing; toilet facilities for workersDeleted without substitutionDo not answer from those model sections.
Section 312.9.1 / 312.9.2Backflow assembly testing312.9.1 amended; 312.9.2 deleted"Annual" testing becomes testing at the time of installation. Paired with new 608.1.1, assemblies are tested at installation and after relocation.
Sections 403, 404, 405.2, 405.3, 405.3.1, 410.1, 410.2Minimum and accessible facilities, fixture setting, drinking fountainsDeleted; "See Chapter 29 of the Indiana Building Code"Fixture-count, clearance and accessibility answers come from the building code.
Section 502.1.1 (new)Elevation of ignition sourceAddedIgnition sources in garages and hazardous locations must be at least 18 inches above the floor.
Section 504.2 / 504.2.1 (new)Bottom fed water heatersRewritten / addedCheck valve plus expansion tank, or a vacuum relief valve; cold water piping must rise above the top of the heater before connecting to the tank inlet.
Table 605.3 / Table 702.2Copper tubing typesAmendedType M copper is struck from water service; M and DWV copper struck from underground sanitary drainage.
Section 608.14.1 and 608.15.4Backflow preventer location; vacuum breakersRewritten12-inch clearance under the assembly, permanent platform above 5 feet, RPZ horizontal; AVB critical level 6 inches above the flood level rim, PVB 12 inches above all downstream piping and outlets.
Section 710.3 (new)Minimum underground drainage sizeAddedMinimum 2-inch nominal sanitary drainage pipe underground within a building.
Section 802.4Clothes washer standpipeSentence added"A trap for a clothes-washer standpipe receptor shall not be installed below the floor."
Section 904.1Vent roof extension heightBlank filledOpen vent pipes terminate at least six (6) inches above the roof.
Sections 917.3.3 and 917.8Air Admittance ValvesRewritten / amendedAAVs shall not serve as the vent terminal for vent stacks or stack vents, and shall not be used to vent sump pits. ASSE 1050 (stack-type AAV) is struck from the referenced standards.
Sections 1002.1 and 1003.1Traps and interceptorsAmendedA combination fixture up to three compartments may share one trap; a cleanout is required immediately downstream of every interceptor or separator.
Section 1107.2Secondary roof drain separate systemsDeleted without substitutionDo not cite 1107.2 in Indiana; sizing of secondary drains stays in 1107.3.
Chapter 12Special Piping and Storage SystemsDeleted; "See the Indiana Fire Code (675 IAC 22)"Medical gas and similar systems are answered from the fire code.

Speed-Searching Techniques During the Exam

Under timed conditions, the difference between passing and failing is the ability to locate code text in 30 to 45 seconds rather than 3 to 4 minutes. Use these three systematic search rules:

1. The "Code Noun" Rule

When reading a question stem, extract the primary technical noun rather than descriptive adjectives. For example, if a question asks: "What is the maximum horizontal distance permitted between supports for 3-inch Schedule 40 PVC DWV piping?"

  • Do NOT look up "Maximum" or "Horizontal".
  • Look up Hangers or Piping Supports in the index.
  • Notice that Hangers and Supports are governed by Chapter 3 (Section 308).
  • Proceed directly to Table 308.5, find the row "PVC pipe", and read the maximum horizontal spacing (4 feet).

2. The Index-First Protocol

The index of the 2006 IPC is exceptionally detailed. If you do not know the exact section number off the top of your head, go straight to the back of the book. Look up the primary topic (e.g., Traps, Vents, Water Heaters, Cleanouts), review the sub-entries, and jump directly to the section citation.

3. Verification Against 675 IAC 16-1.4

Once you find a section in the 2006 IPC, perform a mental check: Is this an item commonly modified by Indiana?

  • Administrative authority? (Check Indiana Chapter 1, 675 IAC 12 and IC 25-28.5)
  • Burial depth of a water service? (Check Indiana Table 305.6.2 — it is county by county)
  • Minimum fixture count, water closet clearance or accessibility? (Check Chapter 29 of the Indiana Building Code)
  • Backflow preventer location or vacuum breaker height? (Check amended 608.14.1 and 608.15.4)
  • Air admittance valve on a stack or a sump pit? (Check amended 917.3.3 and 917.8 — both prohibited)
  • An appendix answer? (Check 101.3 first — only Appendices C and E are adopted)

Keeping your 675 IAC 16-1.4 amendment document tabbed right beside your IPC allows you to verify state exceptions in seconds.

Test Your Knowledge

Under 675 IAC 16-1.4, what happens to Chapter 1 (Administration) of the model 2006 IPC in Indiana?

A
B
C
D
Test Your Knowledge

In the 2006 International Plumbing Code, which table must a plumber reference to determine the maximum permissible horizontal developed length between a fixture trap and its qualifying vent?

A
B
C
D
Test Your Knowledge

A question asks you to size a water distribution system using the IPC appendix method. Which appendix may you rely on in Indiana, and why?

A
B
C
D