7.1 Reading Plumbing Drawings, Isometrics, Symbols & Schedules
Key Takeaways
The Prov Alabama Journeyman Plumber exam has 5 questions on Drawings and Plan Reading out of 75, and plan sizing skills also support the 9 Sizing and Design questions.
Isometric riser diagrams show horizontal pipe at 30 degrees from horizontal and vertical pipe as true vertical lines; they are not to scale, so lengths come from the plans or the given dimensions.
Drafting symbols for pipe turning toward or away from the viewer, line types and valves vary between offices, so the drawing legend and fixture schedule always govern.
A plumbing fixture schedule lists each fixture mark with its model, connection sizes and often its dfu and wsfu, and plan questions are usually answered by adding loads from the schedule along the flow path.
Plan-review questions usually test code points visible on a drawing, such as sanitary tees used vertical to horizontal, vents turning horizontal below the flood rim, cleanout spacing and missing backflow protection.
Why this section matters
The exam gives 5 questions to Drawings and Plan Reading. Those questions, plus many Sizing and Design items, show a floor plan or an isometric and ask you to read sizes, find a load, or spot a violation. Reading drawings quickly saves minutes for the harder calculations.
The sheets in a plumbing set
| Sheet type | What it shows | Plumbing use |
|---|---|---|
| Architectural floor plans (A-series) | Walls, doors, rooms and fixture locations | Wall thickness, chase space, accessible clearances |
| Plumbing floor plans (P-series) | Pipe routing, sizes, cleanouts, floor drains, riser locations | Horizontal layout; underground and above-ceiling runs |
| Isometric riser diagrams | Three-dimensional pipe paths for water, DWV and vents | Connections, fittings, venting method, flow direction |
| Sections and elevations | Vertical cuts through the building | Slab and ceiling elevations, inverts, sleeves |
| Details | Enlarged assemblies | Water heater piping, backflow assemblies, interceptors, cleanout plugs |
| Schedules and legends | Fixture marks (P-1, P-2), models, connection sizes, notes | Fixture units, trap and supply sizes, symbol meanings |
| Site or civil sheets | Building sewer, water service, manholes | Invert elevations, separation, tie-in points |
Where a drawing and the written specifications conflict, the contract documents usually say which governs. On a code exam, the code governs over a drawing that shows a violation.
Isometric drawings
An isometric riser diagram shows piping in three dimensions on a flat sheet:
- Vertical pipe is drawn as a true vertical line.
- Horizontal pipe runs along two axes drawn at 30 degrees above horizontal, to the left and to the right.
- Offsets at 45 degrees are often drawn with a shaded or hatched triangle that shows which plane the offset lies in.
Isometrics are usually not to scale. They show connection order, fittings, venting and flow direction. Take lengths from the dimensioned plans or from the problem statement.
vertical (true plumb)
|
|
30 deg ______|______ 30 deg
/ \
left horizontal right horizontal
Line types and symbols
Offices use different conventions, so always read the legend first. Common conventions:
| System | Typical label or line |
|---|---|
| Domestic cold water | CW, solid line with a long dash-short dash pattern |
| Domestic hot water | HW, dash with two short dashes |
| Hot water return | HWR, dash with three short dashes |
| Sanitary waste or soil | W or S, heavy solid line |
| Vent | V, dashed line |
| Storm drain | ST or SD |
| Gas | G |
| Acid waste | AW |
| Fitting or device | Typical symbol |
|---|---|
| Pipe turning up, toward the viewer | Circle with a center dot, or a full circle (check the legend) |
| Pipe turning down, away from the viewer | Half circle, or a circle with a cross (check the legend) |
| Gate valve | Two triangles tip to tip ("bow tie") |
| Globe valve | Bow tie with a solid dot between the triangles |
| Check valve | Bow tie with a flow arrow or an angled line |
| Cleanout | CO, FCO (floor), WCO (wall), COTG (cleanout to grade) |
| Floor drain | FD, square or circle with a grate pattern |
Schedules: where the numbers live
A plumbing fixture schedule gives each fixture a mark (for example P-1 water closet, P-2 lavatory) and lists its manufacturer and model, rough-in dimensions, trap size, cold, hot and waste connection sizes and often its dfu and wsfu. Read the schedule before you start adding:
- Is the water closet a public 1.6-gpf unit (4 dfu) or a private one (3 dfu)?
- Is it on a flushometer valve (10 wsfu public) or a tank (5 wsfu public)?
- Is the urinal 1 gallon per flush or less (2 dfu)?
- Is the shower head rated 5.7 gpm or less (2 dfu, 1-1/2-inch trap)?
Equipment schedules list water heaters (Btu/h, gallons, recovery), pumps (gpm at feet of head), and backflow assemblies (type and size).
Tracing systems on a drawing
Water:
- Public main, corporation stop and service pipe (at least 3/4 inch).
- Curb valve and meter, then a full-open valve on the meter discharge.
- Full-open valve at the building entrance.
- Containment backflow assembly, if the supplier requires it.
- PRV with a strainer if static pressure is over 80 psi.
- Mains and risers, with valves at riser bases where required, and the water heater's cold-water valve.
- Branches and fixture supplies, each ending within 30 inches of the fixture.
Drainage:
- Fixture and trap (2- to 4-inch seal).
- Fixture drain, within the Table 909.1 distance to the vent.
- Horizontal branch, sized by Table 710.1(2).
- Stack, sized by Table 710.1(2) for both total and per-interval load.
- Stack base, using Table 706.3 fittings.
- Building drain, sized by Table 710.1(1) at its slope, ending 30 inches outside the wall.
- Building sewer to the public sewer.
Vents:
- Vent takeoff above the drain centerline.
- Vertical rise to 6 inches above the highest flood rim.
- Branch vent graded to drain back.
- Vent stack or stack vent (sized by Table 906.1).
- Terminal: away from openings, at the local roof height.
A plan-review checklist (common exam "violations")
| Look for | Code |
|---|---|
| Sanitary tee used vertical to horizontal, or laid flat | Table 706.3 |
| Double sanitary tee on back-to-back water closets closer than 18 inches | 706.3 |
| Vent turning horizontal below the flood rim | 905.4 |
| Fixture drain too long or too much fall before the vent | 909.1, 909.2 |
| S trap, drum trap or building trap | 1002.3, 1002.6 |
| No cleanout within 100 feet, at a turn over 45 degrees, or at the drain-to-sewer junction | 708.1 |
| Hose bibb without a vacuum breaker; irrigation tap without backflow protection | 608.16.4.2, 608.17.5 |
| Relief valve line trapped, valved or reduced | 504.6 |
| Kitchen sink on a bathroom wet vent | 912.1 |
| Disposer draining to a grease interceptor | 1003.3.2 |
Exam traps
- Legend first. Symbols vary between offices.
- Isometrics are not to scale. Use the stated dimensions.
- Schedule first. Public versus private and flush valve versus tank change both dfu and wsfu.
- Blueprint weight: Drawings and Plan Reading is 5 of 75 questions.
On an isometric riser diagram, how are horizontal pipes usually drawn?
As true horizontal lines at 0 degrees
On 30-degree axes, to the left and right
As dashed lines to show they are hidden
On 45-degree axes, to the left and right
A floor plan shows a circle with a center dot on a pipe line. What should you do to confirm what it means?
Assume it always means the pipe turns down, away from you
Assume it is always a cleanout brought up to the floor
Check the legend, since symbols vary between drafting offices
Ignore it, since plumbing plans do not use pipe symbols
According to the Prov candidate bulletin, how many of the 75 questions on the Alabama Journeyman Plumber exam cover Drawings and Plan Reading?
6 questions
10 questions
5 questions
20 questions