What is process safety, and how does it differ from personal (occupational) safety?

Tap to reveal definition
Card 1 of 50Process Safety Leadership

Filter by Topic

Jump to Card

About These NEBOSH PSM Flashcards

These 50 flashcards are designed to help you memorize key terms and definitions for the NEBOSH HSE Certificate in Process Safety Management. Each card shows a term on the front and its definition on the back—the classic flashcard format for vocabulary memorization. Use these alongside our practice questions to build both recall and comprehension.

Topics Covered

Process Safety Leadership7 cards
Process Safety Management Systems2 cards
Risk Assessment Techniques6 cards
Asset Integrity3 cards
Permit-to-Work3 cards
Shift Handover and Contractors2 cards
Operating Procedures and Safe Limits4 cards
Safety-Critical Elements3 cards
Utilities and Static Electricity4 cards
Dangerous Substances and Reactions5 cards
Bulk Storage2 cards
Fire and Explosion Hazards3 cards
Explosion Prevention and Protection4 cards
Emergency Planning2 cards

Complete Flashcard Reference

Review every term in this set. Open any term to reveal its definition.

What is process safety, and how does it differ from personal (occupational) safety?

Process safety uses engineering and management controls to prevent and limit major fires, explosions and toxic releases from hazardous processes. Personal safety addresses harm to individuals from work activities, such as falls and manual handling injuries. An improving injury rate can coexist with deteriorating barriers against a major accident.

Why did the 2005 BP Texas City explosion happen on a site with a low personal-injury rate?

During start-up of the ISOM unit, the raffinate splitter tower overfilled. Liquid discharged to an atmospheric blowdown drum and stack, which overflowed and formed a vapour cloud that ignited. Fifteen people died, many in or near temporary trailers. The CSB and Baker Panel documented how reliance on personal injury statistics gave a misleading picture of process safety performance.

What is the role of senior leadership and the board in process safety management?

The board sets priorities, allocates resources and reviews whether critical controls are effective. Leaders check process safety indicators, fund integrity work, and act on concerns from operators and maintenance staff. After Buncefield, the Process Safety Leadership Group published fuel-storage standards that reinforce the need for visible leadership.

What does 'dual assurance' mean when setting process safety performance indicators?

HSE guidance HSG254 asks you to pair indicators for each critical risk control system: a lagging indicator showing the control has already failed (a loss of containment, a relief valve that failed its test), and a leading indicator showing whether it is working as intended now (safety-critical inspections completed on time, overdue actions, alarm rationalisation status). Lagging data alone means you only learn about a barrier after it has failed.

Which failure caused the 1974 Flixborough explosion, and what does it teach about change?

A temporary 20-inch dogleg bypass connected reactors 4 and 6 after reactor 5 was removed. The improvised assembly lacked adequate design calculations and testing. Its failure released hot cyclohexane and caused a vapour cloud explosion that killed 28 people. Temporary plant changes need documented engineering assessment and approval before use.

What must a management of change (MOC) procedure cover before a change is approved?

Define the change and its technical basis, assess the hazards, obtain authorisation, and update drawings, procedures and training before returning affected equipment to service. Set an expiry and restoration plan for temporary changes. Replacement in kind means meeting the existing design specification and duty. Changes in staffing or responsibilities also need review where they affect safety-critical work.

How is competence defined in process safety, and what does a competence management system do?

Competence combines the knowledge, skills and experience needed to perform assigned tasks consistently to the required standard. Identify safety-critical tasks, define the standard, assess people against it, then provide training and reassessment as needed. Verify performance in the role as well as qualifications.

What is a process safety management system for, and how is the CCPS framework structured?

A process safety management system assigns responsibilities, sets standards, monitors controls and follows up findings throughout the plant life cycle. The CCPS Risk Based Process Safety framework groups twenty elements under four pillars: commit to process safety, understand hazards and risk, manage risk, and learn from experience.

Under the COMAH Regulations 2015, what does a lower-tier site have to do that an upper-tier site must exceed?

In Great Britain both COMAH tiers must notify the Competent Authority, prepare a major accident prevention policy supported by a proportionate safety management system, and make prescribed information available to the public. Upper-tier operators must also submit a safety report, prepare an internal emergency plan and supply information for the local authority's external plan where required. Tier depends on the applicable quantities and aggregation rules for dangerous substances.

What is a HAZOP study, and how are guide words used?

A multidisciplinary team uses guide words to find deviations from design intent. For a node on a process and instrumentation diagram, combine a guide word such as MORE or REVERSE with a parameter such as pressure or flow. The team records credible causes, consequences, safeguards and actions.

When would you use a HAZID rather than a HAZOP?

Use HAZID early to screen broadly for hazards such as loss of containment, natural events, transport and layout. Use a detailed HAZOP when the design intent and drawings are defined enough for a node-by-node deviation review. Earlier, coarser HAZOPs and later reviews of operating plant can also be appropriate.

What qualifies as an independent protection layer in LOPA?

LOPA estimates the frequency of a specified consequence using the initiating-event frequency and the probabilities of failure on demand of credited layers. A layer must be effective for the scenario, auditable, and independent of the initiating event and other credited layers. An alarm sharing the equipment whose failure initiates the event needs demonstrated independence before it can receive credit. Consider inherently safer design first, then assess the available preventive and mitigative measures for the specific scenario.

What do the left and right sides of a bow-tie diagram represent?

The knot is the top event - loss of control, typically loss of containment. The left side lists the threats that could cause it and the preventive barriers stopping each threat reaching the top event. The right side lists the consequences and the mitigative or recovery barriers that limit them once the top event has happened. Escalation factors hang beneath barriers to show what could defeat them, each with its own control. Its value is that every barrier can be named, owned, resourced and monitored.

What are the inherent safety principles, and how do they apply to Bhopal?

Minimisation reduces hazardous inventory. Substitution uses a less hazardous material or route. Moderation uses less severe conditions or a less hazardous form. Simplification reduces opportunities for error. At Bhopal, water contaminated stored methyl isocyanate and triggered a runaway release. A smaller inventory would have limited the amount available for release.

What does ALARP require beyond simply having controls in place?

ALARP means the risk has been driven down to the lowest level reasonably practicable: a further measure must be implemented unless its cost in money, time and trouble would be grossly disproportionate to the risk reduction it buys. The higher the risk, the greater the disproportion needed to justify inaction, and the burden of showing that sits with the duty holder. Sitting in the tolerable region with no further action and no argument recorded is not ALARP.

What does 'asset integrity' mean, and what are its three strands across the life cycle?

Asset integrity is the ability of equipment to perform as intended, effectively and efficiently, throughout its whole life while protecting people and the environment. Design integrity means it was specified and built right for the duty; technical integrity means inspection, testing and maintenance keep it fit for service; operating integrity means it is run inside its design envelope by competent people. Integrity is usually lost quietly - deferred inspections, temporary repairs, creeping change - long before anything leaks.

Compare breakdown, planned preventive and condition-based maintenance for process plant.

Run-to-failure means repairing equipment after it fails and is suitable only where the consequences are acceptable. Planned preventive maintenance acts at set time or usage intervals. Condition-based maintenance uses evidence such as vibration trends, oil analysis or wall-thickness readings to decide when to intervene. Safety-critical equipment needs maintenance and testing appropriate to its failure risk.

What is risk-based inspection, and why is corrosion under insulation so dangerous?

Risk-based inspection ranks equipment by likelihood and consequence of failure so inspection effort and intervals target what matters instead of treating every vessel alike. Corrosion under insulation is a classic RBI target because it is hidden - water penetrates the cladding and attacks the wall out of sight, so it is only found by stripping insulation or using specialist techniques. Ultrasonics measure wall loss, radiography finds weld defects, dye penetrant reveals surface-breaking cracks, and magnetic particle inspection finds surface and near-surface flaws in ferrous steel.

What is a permit-to-work system for, and what are its four operating stages?

A permit is the formal way to authorise hazardous work and communicate its scope, hazards, controls and isolations. The issuer defines the conditions, the performing authority accepts them, and completed work is handed back with the plant in an agreed condition. The issuer or area authority verifies reinstatement and closes the permit. If work is suspended, keep the permit and any active isolations visible until formally resolved.

What permit-to-work and shift handover failures contributed to Piper Alpha?

A pressure safety valve on the condensate pump system had been removed and the open connection temporarily blanked. The Cullen Inquiry identified failures in the permit-to-work system and handover that left the next shift unaware of the equipment's condition. The disaster killed 167 people and led to a new offshore safety case regime. Related live and suspended permits must remain visible during handover and before restart.

What isolation standards are used to make process plant safe for maintenance?

HSG253 uses the task, substance, release potential and consequences to choose a baseline isolation. Positive isolation uses physical separation or a rated blind or spade. Proved valved isolation uses a suitable valve arrangement with a means of confirming its effectiveness. Select and secure the isolation, remove pressure and hazardous inventory, and verify the condition before work. Vessel entry calls for especially stringent isolation.

What makes a shift handover safe rather than a formality?

Handover works when it is a two-way, face-to-face conversation with time formally allowed for it, supported by a written log so the same information exists in both spoken and recorded form. Both parties carry responsibility: the incoming operator must question, repeat back and confirm understanding rather than just sign the book. The highest-risk handovers are those covering non-routine or incomplete work - suspended permits, overrides and bypasses in place, plant out of service and abnormal conditions.

What must an operator do to manage contractors on a major hazard site?

Select on competence and process safety record rather than lowest price, define the scope and the hazards in writing, verify that individuals are trained and competent, brief them on site rules, the permit system and emergency arrangements before work starts, supervise and monitor the work in progress, and review performance afterwards. The client cannot contract out its duties. Multi-employer sites fail when nobody owns the interface between contractor activity and live plant.

What is a safe operating envelope, and what should happen as the plant approaches its limits?

The safe operating envelope defines safe limits for process variables such as pressure, temperature, flow, level and composition. Procedures state the normal range, the action required on deviation and relevant alarms or trips. Record and investigate an excursion. It shows that a safe limit was already crossed and can warn of a worsening trend.

What makes a standard operating procedure effective for process safety?

It sets out step by step how to run a specific part of the process so the safe operating envelope is maintained. It should be written with the operators who use it, validated against the plant as built, cover normal, abnormal, start-up, shutdown and emergency conditions, state the limits and the consequences of exceeding them, be a controlled document with a review date, and be revised through management of change whenever plant or process changes. A procedure that no longer matches the plant trains people to ignore procedures.

Why can start-up and shutdown raise process safety risk?

Transient operations can present higher risk because flow paths, inventory, temperatures and pressures change, and operators may need more manual actions. Follow the written sequence and hold points. Before restart, verify plant readiness, the status of isolations and safeguards, and formal authorisation of any override.

What is the difference between a planned shutdown, an emergency shutdown and a total shutdown?

A planned shutdown follows a defined sequence to reach a safe condition for maintenance or turnaround. An emergency shutdown uses the plant's specified protective actions, which may include stopping feeds, isolating inventory or depressurising to a safe system. A total shutdown covers the whole installation. Retain essential safety services as required and verify residual pressure, inventory and stored energy before opening equipment.

What is a safety-critical element, and why does each one need a written performance standard?

A safety-critical element is any system, equipment or structure whose failure would cause or substantially contribute to a major accident, or whose purpose is to prevent or limit one - emergency shutdown valves, gas and fire detection, relief systems, firewater, blast and fire walls. A performance standard states exactly what the element must achieve and how that is verified, so inspection, testing and maintenance can be audited against a defined claim rather than a general intention, and so nobody quietly downgrades it.

What does the acronym FARSI stand for in a performance standard?

Functionality states what the element must do. Availability is the proportion of time it is able to do it. Reliability is the probability it performs as required under stated conditions. Survivability is its ability to work in the accident conditions for which it is credited. Interdependency covers supporting systems such as power and instrument air.

What is a safety instrumented function, and what does its SIL express?

A safety instrumented function typically uses a sensor, logic solver and final element to bring the process to a specified safe state. For low-demand operation, SIL is expressed using average probability of failure on demand (PFDavg). SIL 1 is 0.01 to below 0.1, SIL 2 is 0.001 to below 0.01, and SIL 3 is 0.0001 to below 0.001. Architecture, proof testing and bypass control must support the claimed integrity.

What hazards arise from steam and water in the process industries?

Steam leaks can cause severe scalds. Condensate in steam lines can cause water hammer and damage pipes or fittings. A loss of steam can disrupt process heating or stripping. Loss of cooling water can allow an exothermic reaction to run away. Water entering a process that contains water-reactive material can also cause a hazardous reaction.

Why must a valve's failure action on loss of instrument air be defined?

Loss of instrument air, power, cooling water, nitrogen or steam can affect several barriers together. Define each valve's required failure action, such as fail-open, fail-closed or fail-in-place, and verify that the actuator arrangement delivers it. For example, a feed valve may need to close while cooling flow must continue. Assess utility failure in the hazard review.

How does static electricity ignite flammable atmospheres, and how is it controlled?

Liquid transfer, splash filling and powder handling can separate charge. A discharge can ignite a flammable vapour or dust cloud. Bond conductive parts to equalise their potential and earth them to drain charge. Avoid splash filling, control flow velocity and allow charge relaxation where required. Low-conductivity materials may need additional controls because earthing the equipment does not remove all charge from the product.

Which electrical ignition sources must be controlled on a process plant, and how?

Switching sparks, arcing from damaged cables or loose terminals, hot surfaces on motors and lighting, and stray currents from cathodic protection or welding returns can all ignite a flammable atmosphere. Controls are equipment protected to a standard appropriate for the hazardous zone (flameproof, increased safety or intrinsically safe), earthing and bonding, inspection and maintenance to the hazardous-area standard rather than the general electrical standard, control of portable equipment through the permit system, and hot work permits with gas testing before and during the job.

What does hazardous area classification under DSEAR require?

Places where an explosive atmosphere may occur are classified into zones by how likely and how long the atmosphere is present. For gases, vapours and mists: Zone 0 is present continuously, for long periods or frequently; Zone 1 is likely to occur occasionally in normal operation; Zone 2 is not likely in normal operation and short-lived if it does. Dusts use Zones 20, 21 and 22 on the same logic. Equipment must be selected to a category suitable for its zone, and the classification drives ignition control, permits and the DSEAR risk assessment.

How does the physical form of a dangerous substance change the risk it presents?

Physical form affects release and dispersion. Dense LPG or petrol vapour can collect in pits and drains. Gases lighter than air can still accumulate where ventilation is poor. A pressurised liquefied gas can flash on release. A flammable mist can ignite below the liquid's bulk flash point, and a combustible solid dispersed as fine dust can burn rapidly or explode.

Define flashpoint, LEL and UEL - and explain why a mixture above the UEL is still dangerous.

Flash point is the lowest liquid temperature at which its vapour ignites momentarily with an applied ignition source under specified test conditions. The lower and upper explosive limits are the minimum and maximum concentrations that support flame propagation under the stated conditions. A mixture above the upper limit can enter the flammable range as it mixes with air, for example when a tank is opened or ventilated.

What causes a thermal runaway reaction?

Thermal runaway occurs when heat generation overtakes heat removal and rising temperature further accelerates the reaction. Triggers include loss of cooling or agitation, excessive or rapid addition, wrong addition order, contamination and high initial temperature. Gas generation or boiling can then overpressurise the equipment.

What measures mitigate the consequences of a thermal runaway?

Use reaction testing to set safe quantities, addition rates, temperatures and cooling. Protective measures can include feed trips, emergency cooling, a compatible quench or dump system, and relief routed to a suitable safe location. Assess whether vapour and liquid can discharge together and use an appropriate two-phase sizing method when that flow is credible.

What are the main hazards of bulk atmospheric storage of flammable liquids?

Main hazards include overfill, rim seal and roof fires, pressure or vacuum when tank vents are blocked, corrosion and failure of secondary containment. HSG176 normally calls for the greater of 110% of the largest tank's capacity or 25% of the total tank capacity in a bund. Design also needs to address credible spillage, drainage control and the integrity of the containment.

Why did tank 912 overfill at Buncefield in 2005, and which protection layer failed?

The automatic tank gauge used for routine level control had stuck and had not been repaired, so the control room never saw the rising level. The independent high-level switch that should have shut the filling line as a separate protection layer could not operate, because its test lever needed a padlock fitted to hold it in the working position and that had not been done. Around 300 tonnes of petrol overflowed. The lesson: a high-level trip is a safety-critical element needing its own performance standard, proof testing and maintenance - not a spare level gauge.

Distinguish a pool fire, a jet fire, a flash fire and a fireball.

A pool fire burns over a liquid pool and radiates heat to nearby people and plant. A jet fire is fed by a pressurised release and produces intense local heating where the flame strikes equipment. A flash fire is rapid flame travel through a dispersed cloud with little damaging overpressure. A fireball is a short-lived burning mass that can follow ignition of a large, rapid release.

What is a BLEVE, and how is it prevented?

A boiling liquid expanding vapour explosion occurs when a vessel ruptures and liquid above its boiling point at the new pressure rapidly flashes. Fire can weaken the unwetted wall of an LPG vessel, even while the relief valve operates. Blast and fragments can follow, with a fireball if the release is flammable and ignites. Separation, appropriate vessel cooling or fire protection, drainage and other design safeguards can reduce the risk.

Why do some vapour cloud releases explode while others only flash fire?

A vapour cloud can burn as a flash fire with little overpressure. If combustion accelerates enough, it can generate a damaging blast. Congestion and partial confinement can increase turbulence and accelerate the flame. Buncefield research also examined the effects of local geometry and enclosures, so an outdoor cloud must not be assumed incapable of producing severe overpressure.

What are the five elements of the dust explosion pentagon?

The dust explosion pentagon adds dispersion at an explosible concentration and confinement to the fire triangle of combustible dust, an oxidiser and ignition. Confinement allows pressure to build. An unconfined dust cloud can still burn as a flash fire. Finer particles often burn more rapidly, but actual explosibility and severity depend on the material and test conditions.

How can a secondary dust explosion cause more damage than the initial event?

An initial explosion can lift dust deposits from surfaces and ductwork. If this larger airborne cloud ignites, secondary explosions can spread through the building. Control dust at the source and remove deposits safely. Kst measures the rate of pressure rise under standard test conditions and, with Pmax, informs explosion protection design.

Name the main explosion protection measures used when prevention alone cannot be relied on.

Containment designs equipment to withstand the explosion pressure. Venting releases pressure through sized panels to a safe location. Suppression detects an incipient event and injects suppressant quickly to limit pressure. Isolation stops flame or pressure from propagating between connected equipment. Inerting and ignition-source control help prevent an explosion.

What is the difference between active and passive fire protection, and why is detection critical?

Passive measures such as fire walls and intumescent coatings protect without a powered response. Active measures such as deluge, sprinklers and foam must operate on demand. Gas detection can support isolation before a release ignites. Flame detection identifies a fire that has already started and can trigger alarm, shutdown or suppression where designed.

What must a major accident emergency plan contain, and how often is it tested?

Plans identify command roles, alarm and communications, muster and accountability, measures to control incidents, emergency-service coordination and recovery arrangements. Under COMAH the upper-tier operator prepares the internal plan. The local authority prepares the external plan unless an exemption applies. The operator and local authority each review and test their required plan at suitable intervals of no more than three years.

What are the priorities of on-site emergency response to a process fire?

Raise the alarm, protect people and follow the site emergency plan. Under incident command, trained responders may isolate or depressurise affected plant, cool threatened equipment or apply firefighting media when the plan and conditions allow it. Preventing escalation matters because fire impingement can cause neighbouring equipment to fail and release more inventory.

Frequently Asked Questions

How is the NEBOSH HSE Certificate in Process Safety Management assessed?

PSM1 is a remotely proctored, closed-book online assessment. It has 40 compulsory multiple-choice questions worth one mark each, including 10 extended scenario questions. It samples all four elements. You have 90 minutes once you start and must finish within the monthly sitting's 24-hour assessment window.

What is the NEBOSH PSM pass mark, and is there a Merit or Distinction grade?

Pass requires at least 60%, which is 24 of 40 marks. A lower score is a Refer. NEBOSH states that results are issued within 15 working days and that the parchment normally follows within 20 working days of confirmation of a pass.

What is the NEBOSH PSM pass rate?

NEBOSH's public qualification and syllabus materials do not give an overall candidate pass rate. The published pass mark is 60%. The assessment samples all four syllabus elements.

Can I self-study for the NEBOSH PSM certificate?

NEBOSH requires enrolment with an accredited Learning Partner, who delivers the course and registers you for PSM1. The assessment registration deadline is 10 working days before the sitting. Flashcards can supplement your course.

What happens if I am referred (fail) in Unit PSM1?

After a Refer, your Learning Partner can register you to re-sit PSM1 on another monthly assessment date. NEBOSH places no limit on re-sits. The published registration deadline is 10 working days before the assessment.

What does the PSM1 syllabus cover, and how is it weighted?

The syllabus lists four elements with recommended tuition hours. Process safety leadership has 4 hours, management of process risk 9, process safety hazard control 10, and fire and explosion protection 5. The fourth element includes emergency response. NEBOSH gives 28 hours in total and specifies that the assessment includes at least one question from each element. It does not publish percentages of marks by element.

How long does the NEBOSH PSM qualification take to study?

NEBOSH lists 49.5 notional learning hours, including 28 taught hours, 20 hours of private study and 1.5 hours for the assessment. The qualification is rated SCQF Level 7 with 5 credits, comparable to RQF Level 4.

Does the NEBOSH PSM certificate expire?

The current NEBOSH learner guide specifies no expiry or renewal requirement for the qualification. Maintaining competence for safety-critical work remains a separate responsibility.