What does an authorized worker verify after applying lockout/tagout?
Verify that the equipment is isolated and de-energized before starting service. Address stored energy as part of the isolation procedure.
Filter by Topic
Jump to Card
About These NATE CHP-5 Flashcards
These 50 flashcards are designed to help you memorize key terms and definitions for the NATE Certified HVAC Professional (CHP-5). Each card shows a term on the front and its definition on the back—the classic flashcard format for vocabulary memorization. Use these alongside our practice questions to build both recall and comprehension.
Topics Covered
Complete Flashcard Reference
Review every term in this set. Open any term to reveal its definition.
What does an authorized worker verify after applying lockout/tagout?
Verify that the equipment is isolated and de-energized before starting service. Address stored energy as part of the isolation procedure.
Where do you look for a chemical’s handling hazards and first-aid measures?
Check the product’s safety data sheet (SDS). It also gives guidance on protective equipment, storage, and accidental releases.
What is three-point contact when climbing a portable ladder?
While climbing, keep either both hands and one foot or both feet and one hand on the ladder.
Why ream the inside of freshly cut copper tubing?
Reaming removes the ridge left by the cutter. Keep the shavings out of the tubing so debris cannot enter the refrigerant circuit.
What does a tubing bender preserve when changing the direction of a copper line?
A correctly sized bender helps preserve the tubing’s round cross-section. A kink reduces the flow area and can create a restriction.
What should you do when an HVAC route crosses a structural truss member?
Plan a route that preserves the truss. If it must be altered, obtain approval from a registered design professional and follow the locally adopted code.
Where does refrigerant absorb heat from indoor air during cooling?
In the evaporator. Low-pressure refrigerant absorbs heat as it boils, cooling the air that passes over the coil.
What does a metering device do in a vapor-compression system?
It regulates refrigerant flow into the evaporator and creates a pressure drop. The lower pressure lets the refrigerant boil at a temperature below that of the air being cooled.
Which U.S. credential covers service that could release refrigerant from HVAC equipment?
EPA Section 608 technician certification is the federal credential for covered work. It is separate from NATE CHP-5. The required certification type depends on the equipment.
Why might a duct penetration through a fire-rated wall need a listed fire damper?
The damper closes in response to heat to help limit fire spread through the opening. Check the locally adopted code for the assembly and any exceptions.
How much current flows through an 8 Ω resistive load supplied with 24 V DC?
3 A. Ohm’s law gives I = V ÷ R, so divide 24 V by 8 Ω.
What voltage does each branch of a parallel circuit receive?
Each branch connected across the same two points sees the same voltage. The branch currents depend on the individual loads.
What does a ladder schematic show about an HVAC control circuit?
It shows electrical paths between the supply rails. Follow the switches, safeties, and loads on those paths to work out the sequence of operation.
What is the purpose of the run capacitor in a PSC blower motor?
In a permanent split capacitor (PSC) motor, it stays in the auxiliary winding circuit and shifts that winding’s current phase relative to the main winding, helping produce a rotating magnetic field.
Which conventional 24 V thermostat terminals carry power and common?
R is the transformer’s supply side and C is its common side on a typical single-transformer system. Confirm the terminals on the equipment wiring diagram.
What does a call for cooling do to R and Y on a conventional 24 V thermostat?
The thermostat connects R to Y, sending a cooling demand to the equipment. The equipment’s controls and safeties determine when the compressor can run.
What condition does a furnace draft-proving pressure switch confirm before ignition?
It confirms that the inducer has created the specified pressure differential. A failure to prove draft calls for diagnosis of the inducer, venting, and sensing path.
How does a contactor let a low-voltage control switch a compressor circuit?
The control energizes a coil that moves the contacts. The contacts then complete the separate line-voltage circuit feeding the compressor.
What does a significant voltage drop across closed contactor contacts suggest under load?
Excessive resistance in the contact path, such as damaged contacts or a poor connection. Good closed contacts normally have very little voltage drop.
How is a run capacitor’s measured capacitance judged?
Compare the microfarad reading to the tolerance printed on the capacitor. Measure it only after isolating power, safely discharging it, verifying discharge, and disconnecting it from the circuit.
What happens to relative humidity when air warms without gaining moisture at the same pressure?
Relative humidity falls. The saturation vapor pressure rises as the air warms while the actual vapor pressure stays the same.
How does outdoor-air ventilation help control indoor contaminants?
It brings in outdoor air and removes or dilutes contaminants that build up indoors. Recirculating air through a particle filter serves a different purpose.
At the same dry-bulb temperature and air pressure, what does a larger wet-bulb depression indicate?
Lower relative humidity. Wet-bulb depression is dry-bulb temperature minus wet-bulb temperature. Drier air allows more evaporation from the wet wick.
When can water vapor condense on an uninsulated supply boot?
When the boot’s surface falls below the dew point of the surrounding air. That air becomes saturated as it cools at the surface.
Which two temperature readings locate a moist-air state on a psychrometric chart for the local pressure?
Dry-bulb and wet-bulb temperatures. Their intersection lets you read properties such as humidity ratio, relative humidity, and dew point.
What airflow passes through a 0.75 ft² duct at an average velocity of 640 ft/min?
480 cfm. Multiply the duct cross-sectional area by the average air velocity. Here, 0.75 ft² × 640 ft/min = 480 ft³/min.
What is total external static pressure if supply is +0.31 and return is −0.22 in. w.c.?
0.53 in. w.c. Subtract the signed return reading from the supply reading at the equipment manufacturer’s specified test points.
What does a rise in pressure drop across a filter at the same airflow suggest?
The filter is adding resistance, often because of loading. Compare the measured drop with the filter’s baseline or rating at that airflow.
What should guide adjustments to branch dampers during air balancing?
Measure the airflow at each outlet and compare it with the design target for that room. Recheck other outlets after each adjustment because changing one branch can redistribute airflow.
How can a closed bedroom door interfere with supply airflow?
Without an adequate return path, supply air pressurizes the room and can reduce delivered airflow. A properly sized return duct, transfer grille, or jump duct provides a way back.
Why flow regulated dry nitrogen through copper tubing during brazing?
Nitrogen displaces oxygen and limits oxide scale inside the tubing. Loose scale can contaminate the refrigerant circuit and restrict small passages.
Why does an outdoor unit need the manufacturer’s specified air clearances?
The clearances allow airflow through the outdoor coil and help limit recirculation of discharge air. The installation instructions also specify room for service access.
What is the job of the gasket between a packaged rooftop unit and its curb?
It seals the unit-to-curb interface. A continuous gasket around the specified perimeter and duct openings helps prevent air leakage and water entry.
Why does a draw-through air handler need a correctly sized condensate trap?
Negative pressure at the drain pan can pull air in through the drain and impede drainage. A water seal sized to the manufacturer’s instructions lets condensate leave while blocking that air path.
What does a micron gauge measure during evacuation?
It measures absolute pressure at the system. Lower microns indicate a deeper vacuum. Use the equipment maker’s target and hold procedure to judge the result.
Why should flexible duct be supported without pinching or sagging?
Compression and sharp bends increase resistance and reduce airflow. Use supports and spacing that keep the duct open and follow the manufacturer’s instructions.
Why put a cross-break in a flat rectangular sheet-metal duct panel?
The shallow diagonal bends stiffen the panel and reduce flexing as duct pressure changes.
What determines whether an existing line set can be reused with replacement equipment?
Check the new unit’s requirements for tubing diameter, length and lift, refrigerant and oil compatibility, and line condition. Matching connection sizes alone is insufficient.
Why verify indoor airflow before using refrigerant readings to check the charge at startup?
Airflow changes the load on the indoor coil and affects refrigerant readings. Establish the specified airflow, stabilize the equipment, and use the manufacturer’s charging method.
What should a pre-start check confirm about a gas furnace’s venting?
Confirm that the vent material, routing, and termination meet the furnace installation instructions and local code. Proper venting carries combustion gases outdoors.
What is furnace temperature rise with 121°F supply air and 69°F return air?
52°F. Subtract return air temperature from supply air temperature after operation stabilizes. Compare the result with the furnace nameplate range.
A suction line reads 58°F and its saturated vapor temperature is 43°F. What is the superheat?
15°F. Subtract saturated vapor temperature from measured suction-line temperature at the same location. Use the dew-point value for a blend with temperature glide.
A liquid line reads 89°F and its saturated liquid temperature is 101°F. What is the subcooling?
12°F. Subtract actual liquid-line temperature from saturated liquid temperature at the same location. Use the bubble-point value for a blend with temperature glide.
What does a flue-gas CO measurement tell you about a fuel-burning appliance?
It measures carbon monoxide in the combustion exhaust at the sampling point. A separate ambient measurement checks for CO in occupied air.
What does flue-gas oxygen indicate about excess combustion air?
For a given fuel and a representative, undiluted sample, more residual oxygen generally indicates more excess air. Interpret the reading with CO and the appliance’s specified test conditions.
When replacing only an outdoor unit, what should you verify about the indoor coil?
Verify that the indoor coil and metering device are approved for the new outdoor unit. Use the manufacturer’s match data to confirm compatibility and rated capacity.
What causes a duct panel to make an oil-canning sound as the blower starts?
A broad sheet-metal panel flexes and snaps as pressure changes. Inspect the panel and check for excessive system static pressure.
One room stays warm while the others cool. What should you measure at that room’s supply outlets?
Measure delivered airflow and compare it with the room’s design target. Low flow points toward a local duct, damper, or return-path issue worth investigating.
What does a cooling sensible heat ratio of 0.75 mean?
75% of total cooling changes the air temperature and 25% removes moisture, under the measured or rated conditions. The ratio is sensible cooling divided by total cooling.
How much sensible heat is delivered at 800 cfm and a 25°F temperature rise at standard air density?
About 21,600 Btu/h. Multiply 1.08 × 800 cfm × 25°F. The 1.08 factor assumes standard air density and specific heat, so adjust it for substantially different conditions.
Frequently Asked Questions
What is the NATE CHP-5 exam format?
CHP-5 consists of five separate closed-book, proctored exams with 30 questions and one hour each. Pass all five to earn the certification. NATE allows any exam order and up to six months between exams. You can test in person or with a live online proctor.
What passing score does NATE publish for CHP-5?
NATE lists the result as pass/fail in each CHP-5 exam outline and says the passing score can vary slightly by test form. NATE does not publish a fixed CHP-5 cutoff or a CHP-5 candidate pass rate in its public exam materials.
What experience do I need before taking CHP-5?
NATE recommends formal training and two years of field experience for CHP-5. NATE lists no formal education requirement for certification, and candidates can schedule their own exams without employer sponsorship.
When can I retake a CHP-5 exam after failing?
NATE does not publish a fixed waiting period or a separate rule after three failed attempts for CHP-5. Confirm the earliest date you can rebook with NATE or your testing organization. Your NATE score report shows performance by topic to help you prepare for another attempt.
How long does NATE CHP-5 certification last?
CHP-5 certification is renewed every two years. To renew using continuing education, earn 16 continuing education hours during the certification period and pay the renewal fee.
How should I use these cards for CHP-5?
Use the topic filter for the exam you are preparing to take. Try answering aloud before flipping each card. Use NATE’s published exam outline to identify additional topics to study and practice.
Explore More NATE HVAC Certifications
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
More From This Family
Videos and articles for deeper review.