Cheat sheet

NCLE CLRE Contact Lens Registry Exam Cheat Sheet

Quick Facts

Exam
NCLE Basic CLRE
Exam owner
ABO-NCLE
Format
125 multiple-choice questions
Item scoring
Includes unscored pilot items
Time
2 hours
Delivery
Prometric center or ProProctor
Languages
English and Spanish
Exam fee
$275 per attempt
Pass standard
Modified Angoff cut score
Blueprint
8 domains, 100 specified items

Tear Film Sources

Oil slows loss, water wets, mucin spreads

Oil from meibomian glandsAqueous from lacrimal glandsMucins promote surface wetting

Eye Surface

Lipid layer
Slows tear evaporation
Aqueous tears
Lacrimal glands supply fluid
Mucins
Support surface wetting
Meibomian glands
Supply tear film lipids
Blink
Redistributes tear film
Bulbar conjunctiva
Covers exposed anterior sclera
Palpebral conjunctiva
Lines inner eyelids
Limbus
Cornea meets sclera

Corneal Findings

Epithelium
Outer corneal barrier
Stroma
Bulk of corneal thickness
Endothelium
Pumps fluid out of stroma
Corneal edema
Fluid-related corneal swelling
Neovascularization
New vessels enter cornea
Keratoconus
Corneal thinning and cone-shaped bulging
Blepharitis
Eyelid margin inflammation
Microbial keratitis
Infection involving the cornea

Cylinder Transposition

Add, flip, turn

Add cylinder to sphereFlip cylinder signTurn axis 90°

Spherical Equivalent vs Transposition

Spherical equivalent

  • Sphere + half cylinder
  • One spherical value

Transposition

  • Add full cylinder to sphere
  • Flip cylinder sign
  • Turn axis by 90°

Average power vs equivalent notation

Refractive Patterns

Myopia
Focus in front of retinaMinus
Hyperopia
Focus behind retina without accommodationPlus
Regular astigmatism
Two perpendicular principal meridians
Presbyopia
Age-related loss of accommodation
Anisometropia
Different refraction between eyes
With-the-rule astigmatism
Minus cylinder axis near 180°
Against-the-rule astigmatism
Minus cylinder axis near 90°
Residual astigmatism
Cylinder remaining with lens on

Optical Calculations

Spherical equivalent
Sphere + half cylinder
Transpose sphere
Add signed cylinder to sphere
Transpose cylinder
Reverse cylinder sign
Transpose axis
Rotate 90° within 1–180°
Cylinder axis meridian
Sphere power alone
Meridian 90° from axis
Sphere + cylinder power
Spectacle to corneal plane
Fcornea = Fspec/(1 − dFspec)
Vertex formula distance
d = vertex distance in meters
Vertex strong spherocylinder
Convert each principal meridian
Corneal-plane high minus
Less minus than spectacle power
Corneal-plane high plus
More plus than spectacle power
−8.00 D at 12 mm
−7.30 D at corneal plane
+8.00 D at 12 mm
+8.85 D at corneal plane

Keratometer vs Radiuscope

Keratometer

  • Measures corneal curvature
  • Reads reflected corneal mires

Radiuscope

  • Verifies rigid lens curvature
  • Reports lens surface radius

Cornea vs rigid lens

Instrument Picker

  1. Need central corneal curvature→Keratometer
  2. Need local curvature map→Corneal topographer
  3. Need scleral lens clearance→Anterior segment OCT
  4. Need tear quantity estimate→Schirmer strips
  5. Need tear film stability→Tear breakup time
  6. Need epithelial staining view→Slit lamp with cobalt blue
  7. Need rigid lens base curve→Radiuscope
  8. Need finished lens power→Lensometer

Measurement and Verification

Keratometer
Central anterior corneal curvature
Corneal topographer
Maps corneal surface shape
Anterior segment OCT
Cross-sections and scleral lens clearance
Schirmer test
Tear production via strip wetting
Tear breakup time
Tear film stability
Radiuscope
Verifies rigid lens base curve
Lensometer
Verifies lens power
Diameter gauge
Checks overall lens width
Thickness gauge
Checks lens center thickness

Slit Lamp Techniques

Diffuse illumination
Broad view of ocular surface
Optic section
Corneal cross-section and lesion depth
Cobalt blue
Excites sodium fluorescein
Yellow barrier filter
Improves fluorescein contrast
Retroillumination
Backlights with reflected light
Lid eversion
Exposes upper tarsal conjunctiva

Dk vs Dk/t

Dk

  • Intrinsic oxygen permeability
  • Material-level property

Dk/t

  • Lens oxygen transmissibility
  • Depends on local lens thickness

At fixed Dk, thickness matters

Design Picker

  1. Soft correction for regular cylinder→Soft toric design(Assess rotation on eye)
  2. Distance and near correction→Multifocal trial(Assess vision at both distances)
  3. Irregular cornea needing vault→Scleral lens assessment(Assess clearance and landing)
  4. Rigid optics with soft skirt→Hybrid design assessment
  5. Planned overnight corneal reshaping→Prescribed orthokeratology(Specialty fitting)

Prefit History

Visual goals
Distance, near, and task demands
Prior lens wear
Comfort, vision, wear, and care
Health history
Ocular and systemic conditions
Medication history
Flag effects on ocular surface
Work and hobbies
Hours, dust, and water exposure
Handling assessment
Dexterity and ability to manage lenses

Lens Materials and Geometry

Dk
Material oxygen permeability
Dk/t
Oxygen transmissibility through lens
t
Lens thickness at measured location
Modulus
Material stiffness
Lower contact angle
Better surface wettability
Silicone hydrogel
Silicone boosts oxygen permeability
Rigid gas permeable (GP)
Shape-retaining oxygen-permeable lens
Base curve
Central posterior lens curvature
Smaller base-curve radius
Steeper curve
Same spherical curve, wider chord
Greater sagittal depth
Hybrid lens
Rigid center, soft skirt
Scleral lens
Vaults cornea, lands on sclera

GP Tear Lens Power

SAM = steeper add minus. FAP = flatter add plus.

Steepen for more plus tear powerFlatten for more minus tear powerAdjust rigid lens power oppositely

GP Fit Patterns

Steep spherical GP

  • Central fluorescein pooling
  • Center appears brighter

Flat spherical GP

  • Central apical bearing
  • Center appears darker

Read center, midperiphery, and edge

Fit and Power Picker

  1. Well-settled fit, residual blur→Over-refraction
  2. Toric rotation is repeatable→LARS axis compensation
  3. Toric rotation varies with blinks→Reassess lens fit and design
  4. Spherical GP pools centrally→Check for steep relationship
  5. Spherical GP bears centrally→Check for flat relationship
  6. GP base curve steepened→Add minus to lens power
  7. GP base curve flattened→Add plus to lens power

On-Eye Fit

Soft lens coverage
Cornea covered through blink
Post-blink movement
Movement after spontaneous blink
Push-up test
Mobility and recovery after displacement
Toric orientation marks
Track lens rotation
Stable toric rotation
Allows axis compensation
Spherical GP pooling
Bright center suggests steep fit
Spherical GP bearing
Dark center suggests flat fit
GP edge lift
Peripheral clearance for tear exchange
Over-refraction
Refraction over settled diagnostic lens

Toric Rotation

LARS = left add, right subtract

Use fitter’s viewRequire stable rotationApply to required axisWrap to 1–180°

Daily Wear vs Daily Disposable

Daily wear

  • Remove before sleep
  • Describes wear schedule

Daily disposable

  • Discard after use
  • Describes replacement schedule

Hours on eye vs reuse

Care-System Picker

  1. Daily disposable removed→Discard after use
  2. Reusable lens due for cleaning→Prescribed compatible disinfecting system
  3. Peroxide disinfection chosen→Supplied case and full neutralization
  4. Case contains used solution→Discard solution before refilling
  5. Swimming or showering planned→Remove lenses first

Wear and Handling

Daily wear
Remove before sleep
Daily disposable
One use, then discard
Extended wear
Overnight only when prescribed
Replacement interval
When to discard lenses
Before handling
Wash and dry hands
Soft lens orientation
Bowl shape, edges upright
Soft lens eversion
Rim flares outward
Teach-back
Patient demonstrates application and removal
Swimming or showering
Remove lenses beforehand

Saline vs Disinfecting Solution

Sterile saline

  • Rinse only when directed
  • No disinfection

Compatible disinfecting solution

  • Reduces harmful germs
  • Use full labeled soak time

Select by intended use

Care Systems

Multipurpose solution
Compatible cleaning, disinfection, storage
Sterile saline
Rinses only when directed
Hydrogen peroxide system
Disinfects before required neutralization
Peroxide case
Use supplied neutralizing case
Peroxide timing
Follow full label neutralization time
Rubbing and rinsing
Use recommended disinfecting solution
Fresh solution
Empty case before refilling
Case drying
Air-dry inverted, caps off
Case replacement
At least every 3 months

Symptoms vs Signs

Symptoms

  • Patient reports dryness
  • Patient reports fluctuating vision

Signs

  • Clinician sees corneal staining
  • Clinician observes lens decentration

Patient report vs observed finding

Follow-Up Picker

  1. Pain or new photophobia→Remove lenses, call clinician immediately
  2. Sudden blur or unusual discharge→Remove lenses, call clinician immediately
  3. Dryness without red flags→Assess tears, fit, care habits
  4. Scarce soft lens blink movement→Assess mobility with push-up test
  5. Blur changes after each blink→Check lens movement and rotation

Follow-Up Findings

Subjective review
Comfort, vision, and wear time
Objective review
Acuity, fit, and ocular findings
Injection
Visible ocular redness
Punctate staining
Small scattered epithelial staining spots
Giant papillary conjunctivitis
Enlarged upper tarsal papillae
Corneal warpage
Lens-associated change in corneal shape
Fluctuating toric vision
Check rotational stability
New photophobia
Urgent red flag
Follow-up plan
Document findings and next steps

Release vs Verification

Prescription release

  • Prescriber gives patient copy
  • Triggered by fitting completion

Seller verification

  • Seller sends complete request
  • Eight business hours after receipt

Copy to patient vs seller check

Prescription and Records

Prescription release
Prescriber gives copy after fitting
Release conditions
No required purchase or waiver
Seller fulfillment
Valid copy or verified prescription
Passive verification clock
8 business hours after receiptComplete request
No timely verification response
Complete request verifies by silence
Additional copy on request
Within 40 business hoursValid prescription
Federal expiration baseline
At least one yearDocument medical exceptions
Lens identity
Material and/or manufacturer
Fit parameters
Base curve, diameter when appropriate
Optical parameters
Power, cylinder and axis as prescribed
Digital prescription delivery
Verifiable affirmative patient consent
HIPAA Privacy Rule
Protects PHI at covered entities
Contact lens records
Track parameters and care changes
Inventory and recalls
Track affected lots and records

Common Traps

Radius and Curvature

Smaller radius in mm ≠ Lower curvature power in diopters

Axis Markings

Toric orientation mark ≠ Prescribed cylinder axis

Soft Lens Fit

Identical labeled base curves ≠ Interchangeable on-eye fit

Oxygen and Wear

High oxygen transmissibility ≠ Approval for overnight wear

Peroxide and Insertion

Unneutralized peroxide solution ≠ Ready-to-wear lens

Fresh Solution

Topping off used solution ≠ Refilling an emptied case

Pooling and Staining

Fluorescein under GP lens ≠ Epithelial staining after lens removal

Red Eye Triage

Painful red eye during wear ≠ Routine lens adaptation

Certification and Licensure

National NCLE certification ≠ State authorization to practice

Last Minute

  1. 1.Dispensing and follow-up each 20%
  2. 2.Vertex high powers by meridian
  3. 3.Smaller GP radius means steeper
  4. 4.Radiuscope verifies rigid base curve
  5. 5.Dk/t accounts for lens thickness
  6. 6.GP center pooling suggests steep fit
  7. 7.Stable toric rotation permits axis compensation
  8. 8.Remove lenses before water exposure
  9. 9.Neutralize peroxide in supplied case
  10. 10.Eye pain? Remove lenses, call clinician
  11. 11.Release prescription at fitting completion
  12. 12.Seller verification takes eight business hours
Same family resources

Explore More ABO-NCLE Optician Certifications

Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.