Circulatory System
5-10%of exam
Specimen Collection
45-50%of exam
Specimen Handling, Transport, and Processing
15-20%of exam
Waived and Point-of-Care Testing (POCT)
5-10%of exam
Non-Blood Specimens
5-10%of exam
Laboratory Operations
15-20%of exam
Quick Facts
- Credential
- PBT(ASCP)
- Questions
- 80 multiple-choice
- Time
- 2 hours
- Format
- Computer-adaptive testing
- Passing score
- 400 scaled (100–999 scale)
- Testing center
- Pearson
- Application fee
- $155 nonrefundable
- Blueprint revised
- Sep 25, 2025
Blood Flow
Arteries away, veins return
Serum vs Plasma
Serum
- Separate after blood clots
- Fibrinogen consumed during clotting
Plasma
- Separate anticoagulated blood
- Retains fibrinogen
Check the requested specimen type
Cardiac Circuit
- Right ventricle
- Pumps blood to lungs
- Left ventricle
- Pumps blood to body
- Pulmonary arteries
- Carry blood toward lungs
- Pulmonary veins
- Return blood to left atrium
- Systemic arteries
- Carry blood away from heart
- Systemic veins
- Return blood toward heart
- Capillary beds
- Exchange with tissues
Blood Components
- Erythrocytes
- Carry oxygen via hemoglobin
- Leukocytes
- Immune defense
- Platelets
- Form primary plug
- Hematocrit
- Red-cell fraction by volume
- Whole blood
- Cells suspended in plasma
- Fibrinogen
- Precursor of fibrin
Venous Draw Sequence
Cultures, Citrate, Serum, Heparin, EDTA, Glycolysis inhibitor
Venous vs Capillary Order
Venous
- Cultures lead when ordered
- EDTA follows heparin
Capillary
- Blood gas leads when ordered
- EDTA leads routine microtubes
Choose order by collection route
Tube Picker
- Suspected bloodstream infection, culture ordered→Use ordered culture bottles(Follow laboratory collection protocol)
- PT/INR or aPTT→Use sodium citrate tube(Fill to designated mark)
- Citrate first through empty winged tubing→Prime with approved discard tube(No-additive or citrate discard tube)
- CBC with differential→Use EDTA whole blood(Gently invert after filling)
- Serum specified→Use approved serum tube(Allow clotting before centrifuging)
- Heparin plasma specified→Match required heparin additive(Confirm test directory)
- Coagulation sample, hematocrit above 55%→Contact lab for adjusted citrate(Use laboratory-specified tube)
Patient ID and Prep
- Two identifiers
- Name and birth date, for example
- Patient can answer
- Ask them to state identifiers
- Order verification
- Match identifiers and requested tests
- Preparation check
- Confirm fasting or timing requirements
- Consent discussion
- Explain procedure and obtain consent
- Collection time
- Record actual draw time
Capillary Draw Sequence
Gas if ordered, EDTA, other additives, serum
Hematoma vs Syncope
Hematoma
- Localized swelling or bruising
- Stop draw and apply pressure
Syncope
- Fainting or loss of consciousness
- Stop draw and summon help
Watch the site and patient
Draw Complications
- Two identifiers do not match→Stop and resolve mismatch(Check patient against order)
- Patient declines collection→Stop and notify ordering team(Document per facility policy)
- IV infusing in one arm→Prefer the opposite arm(Follow policy if unavailable)
- Hematoma at selected site→Select another site(Avoid the affected area)
- Patient feels faint mid-draw→Stop draw and withdraw safely(Protect from falls and summon help)
- No flow into evacuated tube→Check seating or replace tube(Avoid blind probing)
Venous Order of Draw
- 1. Blood cultures
- Sterile collection first
- 2. Sodium citrate
- Light blue
- 3. Serum
- Commonly red or gold
- 4. Heparin
- Commonly green
- 5. EDTA
- Commonly lavender or pink
- 6. Glycolysis inhibitor
- Commonly gray
- Closure colors
- Confirm additive on tube label
- Additive tubes
- Invert gently per manufacturer
- Gray tube example
- Sodium fluoride with potassium oxalate
Venous Site and Technique
- Median cubital vein
- Common first choice
- Cephalic vein
- Outer antecubital alternative
- Basilic vein
- Near nerves and brachial artery
- Tourniquet
- Limit to one minute
- Fist pumping
- Avoid during venipuncture
- Cleaned site
- Air-dry before puncture
- Winged set
- Useful for small, fragile veins
- Citrate fill
- 9:1 blood to citrate
Capillary Collection
- Fingerstick site
- Middle or ring fingertip
- Infant heel site
- Medial or lateral plantar heel
- First drop, routine microcollection
- Wipe away with gauze
- Strong squeezing
- Risks tissue-fluid dilution and hemolysis
- 1. Capillary blood gas
- First when ordered
- 2. EDTA microtube
- First among routine microtubes
- 3. Other additive microtubes
- After EDTA
- 4. Serum microtubes
- Collect last
Special Blood Collections
- Adult culture sets
- Use separate peripheral draw sites
- Culture bottle septum
- Disinfect before inoculation
- Cultures and antimicrobials
- Collect before therapy when possible
- Adult culture volume
- Match bottle and facility targets
- Drug trough
- Immediately before scheduled dose
- Newborn dried blood spot
- Saturate circle from one side
Hemolysis vs Clotting
Hemolysis
- Red cells rupture
- May falsely elevate potassium
Clot in EDTA specimen
- Cells trapped in clot
- CBC counts unreliable
Apply assay-specific acceptance rules
Specimen Acceptance
- Missing or mismatched label→Hold and escalate per policy(Verify before further processing)
- Clot in CBC tube→Request recollection per policy(Clot invalidates cell counts)
- Citrate below required fill→Check rejection and redraw policy(Excess citrate relative to blood)
- Hemolysis detected→Apply assay-specific rejection criteria(Interference varies by analyte)
- Add-on outside stability window→Request fresh specimen per policy(Confirm with performing lab)
Processing and Transport
- Bedside label
- Label in the patient's presence
- Accessioning
- Log receipt and match order
- Serum before spinning
- Allow complete clotting
- Centrifuge setup
- Balance load per instrument instructions
- Relative centrifugal force
- Use specified ×g and time
- Aliquot
- Transfer portion and preserve identity
- Bilirubin specimen
- Protect from light
- Transport
- Match temperature, time, and method
Specimen Integrity
- Clotted CBC
- Unsuitable for cell counts
- Underfilled citrate
- May prolong clotting times
- Hemolyzed potassium sample
- Potassium may read falsely high
- Potassium EDTA carryover
- Potassium up, calcium down
- Wrong tube
- Verify test-specific acceptance criteria
- Quantity not sufficient
- Below required specimen volume
- Add-on request
- Check type, volume, and stability
- Chain of custody
- Record each transfer and receipt
Control Failure
Hold, fix, recheck, then retest
Internal vs External Controls
Internal
- Built into kit or device
- Checks specified procedural functions
External
- Separate control material
- Run per manufacturer instructions
Follow the device QC requirements
POCT Result Decisions
- Kit expired or stored improperly→Set kit aside(Replace per policy)
- Required control out of range→Stop patient testing and reporting(Troubleshoot and repeat controls)
- QC acceptable after correction→Repeat affected patient tests(Follow device and facility procedures)
- Result flagged critical→Follow critical-result notification policy(Document notification)
- Device displays invalid result→Troubleshoot per current instructions(Repeat as directed)
Waived Testing Setup
- POCT
- Testing near the patient
- Waived classification
- Applies to specific test systems
- Waived method
- Follow current manufacturer instructions
- Approved specimen
- Use the specified sample type
- Reagents and strips
- Check expiry and storage
- Control schedule
- Follow device instructions and policy
- Urine dipstick
- Read pads at specified times
- Glucose meter
- Check sample and strip compatibility
- Rapid kit control
- Verify control before interpreting result
Clean Catch vs Timed Urine
Clean catch
- One midstream sample
- Reduce contamination during collection
24-hour urine
- Every void after starting discard
- Include final timed void
Use the ordered collection method
Non-Blood Specimen Picker
- Clean-catch urine culture ordered→Use sterile midstream container(Avoid touching container interior)
- 24-hour urine ordered→Collect after discarding starting void(Include void at 24 hours)
- Sputum requested→Coach deep cough(Collect lower-airway secretions)
- Strep throat culture ordered→Use approved throat swab(Sample posterior pharynx and tonsils)
Urine Collections
- Random urine
- Single void without scheduled timing
- Clean catch
- Cleanse before collecting midstream
- Timed urine start
- Discard starting void
- Timed urine finish
- Include final void at deadline
- Missed timed void
- Contact lab for restart instructions
- Urine preservative
- Use test-specific supplied container
Swabs and Other Specimens
- Stool sample
- Keep separate from urine
- Sputum sample
- Deep cough from lower airways
- Strep throat swab
- Tonsils and posterior pharynx
- Swab transport
- Use assay-specified swab and medium
- Cerebrospinal fluid (CSF)
- Follow laboratory handling instructions
- Federal workplace urine testing
- Document custody and verify seals
Proficiency vs Competency
Proficiency testing
- External challenge samples
- Process using routine patient methods
Competency assessment
- Evaluates individual staff performance
- May include direct observation
Know what is being assessed
Exposure Response
- Needlestick or exposed skin→Wash with soap and water(Report immediately)
- Blood splashes into eyes→Flush with water promptly(Report immediately)
- Exposure has occurred→Seek prompt post-exposure evaluation(Follow facility exposure plan)
- Sharps bin at fill line→Replace using facility procedure(Keep sharps containers upright)
Laboratory Quality and Privacy
- Quality assurance
- Monitors the whole testing process
- Quality improvement
- Track errors and verify fixes
- Proficiency testing
- Evaluate performance using external samples
- Personnel competency
- Assess performance of assigned duties
- Preanalytic quality indicator
- Track mislabeled specimens
- Incident investigation
- Document facts and corrective action
- HIPAA Privacy Rule
- Safeguard protected health information
- Chemical safety data sheet
- Check hazards and protective measures
Common Traps
Scaled score
400 on ASCP scaled score ≠ 40% of items correct
Patient identifiers
Name plus birth date ≠ Room plus bed number
Tube selection
Confirmed tube additive ≠ Matching stopper color alone
Winged set priming
Discard tube clears tubing air ≠ Citrate tube provides test specimen
Routine blood tube labeling
Label in patient’s presence ≠ Prelabel before seeing patient
Sample processing
Serum tube needs clotting ≠ CBC specimen needs anticoagulation
Waived test controls
Acceptable control supports testing ≠ Out-of-range control halts testing
Sputum quality
Deep-cough respiratory specimen ≠ Saliva from the mouth
Last Minute
- 1.Match two identifiers before collecting
- 2.Label tubes in patient’s presence
- 3.Draw venous cultures before citrate
- 4.If ordered, capillary gases precede EDTA
- 5.Fill citrate to designated mark
- 6.Invert additive tubes per manufacturer
- 7.Let serum clot before centrifuging
- 8.Check stability before accepting add-ons
- 9.Include final void at 24 hours
- 10.Hold POCT results when QC fails
- 11.Discard used needles into sharps containers
Explore More ASCP Certifications
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
More From This Family
Videos and articles for deeper review.