Cheat sheet

ASCP PBT Cheat Sheet

Quick Facts

Credential
PBT(ASCP)
Questions
80 multiple-choice
Time
2 hours
Format
Computer-adaptive testing
Passing score
400 scaled (100–999 scale)
Testing center
Pearson
Application fee
$155 nonrefundable
Blueprint revised
Sep 25, 2025

Blood Flow

Arteries away, veins return

Right ventricle to lungsLeft ventricle to body

Serum vs Plasma

Serum

  • Separate after blood clots
  • Fibrinogen consumed during clotting

Plasma

  • Separate anticoagulated blood
  • Retains fibrinogen

Check the requested specimen type

Cardiac Circuit

Right ventricle
Pumps blood to lungs
Left ventricle
Pumps blood to body
Pulmonary arteries
Carry blood toward lungs
Pulmonary veins
Return blood to left atrium
Systemic arteries
Carry blood away from heart
Systemic veins
Return blood toward heart
Capillary beds
Exchange with tissues

Blood Components

Erythrocytes
Carry oxygen via hemoglobin
Leukocytes
Immune defense
Platelets
Form primary plug
Hematocrit
Red-cell fraction by volume
Whole blood
Cells suspended in plasma
Fibrinogen
Precursor of fibrin

Venous Draw Sequence

Cultures, Citrate, Serum, Heparin, EDTA, Glycolysis inhibitor

Citrate before clot activatorsEDTA follows heparin

Venous vs Capillary Order

Venous

  • Cultures lead when ordered
  • EDTA follows heparin

Capillary

  • Blood gas leads when ordered
  • EDTA leads routine microtubes

Choose order by collection route

Tube Picker

  1. Suspected bloodstream infection, culture ordered→Use ordered culture bottles(Follow laboratory collection protocol)
  2. PT/INR or aPTT→Use sodium citrate tube(Fill to designated mark)
  3. Citrate first through empty winged tubing→Prime with approved discard tube(No-additive or citrate discard tube)
  4. CBC with differential→Use EDTA whole blood(Gently invert after filling)
  5. Serum specified→Use approved serum tube(Allow clotting before centrifuging)
  6. Heparin plasma specified→Match required heparin additive(Confirm test directory)
  7. Coagulation sample, hematocrit above 55%→Contact lab for adjusted citrate(Use laboratory-specified tube)

Patient ID and Prep

Two identifiers
Name and birth date, for example
Patient can answer
Ask them to state identifiers
Order verification
Match identifiers and requested tests
Preparation check
Confirm fasting or timing requirements
Consent discussion
Explain procedure and obtain consent
Collection time
Record actual draw time

Capillary Draw Sequence

Gas if ordered, EDTA, other additives, serum

Gas first when orderedEDTA first among routine microtubes

Hematoma vs Syncope

Hematoma

  • Localized swelling or bruising
  • Stop draw and apply pressure

Syncope

  • Fainting or loss of consciousness
  • Stop draw and summon help

Watch the site and patient

Draw Complications

  1. Two identifiers do not match→Stop and resolve mismatch(Check patient against order)
  2. Patient declines collection→Stop and notify ordering team(Document per facility policy)
  3. IV infusing in one arm→Prefer the opposite arm(Follow policy if unavailable)
  4. Hematoma at selected site→Select another site(Avoid the affected area)
  5. Patient feels faint mid-draw→Stop draw and withdraw safely(Protect from falls and summon help)
  6. No flow into evacuated tube→Check seating or replace tube(Avoid blind probing)

Venous Order of Draw

1. Blood cultures
Sterile collection first
2. Sodium citrate
Light blue
3. Serum
Commonly red or gold
4. Heparin
Commonly green
5. EDTA
Commonly lavender or pink
6. Glycolysis inhibitor
Commonly gray
Closure colors
Confirm additive on tube label
Additive tubes
Invert gently per manufacturer
Gray tube example
Sodium fluoride with potassium oxalate

Venous Site and Technique

Median cubital vein
Common first choice
Cephalic vein
Outer antecubital alternative
Basilic vein
Near nerves and brachial artery
Tourniquet
Limit to one minute
Fist pumping
Avoid during venipuncture
Cleaned site
Air-dry before puncture
Winged set
Useful for small, fragile veins
Citrate fill
9:1 blood to citrate

Capillary Collection

Fingerstick site
Middle or ring fingertip
Infant heel site
Medial or lateral plantar heel
First drop, routine microcollection
Wipe away with gauze
Strong squeezing
Risks tissue-fluid dilution and hemolysis
1. Capillary blood gas
First when ordered
2. EDTA microtube
First among routine microtubes
3. Other additive microtubes
After EDTA
4. Serum microtubes
Collect last

Special Blood Collections

Adult culture sets
Use separate peripheral draw sites
Culture bottle septum
Disinfect before inoculation
Cultures and antimicrobials
Collect before therapy when possible
Adult culture volume
Match bottle and facility targets
Drug trough
Immediately before scheduled dose
Newborn dried blood spot
Saturate circle from one side

Hemolysis vs Clotting

Hemolysis

  • Red cells rupture
  • May falsely elevate potassium

Clot in EDTA specimen

  • Cells trapped in clot
  • CBC counts unreliable

Apply assay-specific acceptance rules

Specimen Acceptance

  1. Missing or mismatched label→Hold and escalate per policy(Verify before further processing)
  2. Clot in CBC tube→Request recollection per policy(Clot invalidates cell counts)
  3. Citrate below required fill→Check rejection and redraw policy(Excess citrate relative to blood)
  4. Hemolysis detected→Apply assay-specific rejection criteria(Interference varies by analyte)
  5. Add-on outside stability window→Request fresh specimen per policy(Confirm with performing lab)

Processing and Transport

Bedside label
Label in the patient's presence
Accessioning
Log receipt and match order
Serum before spinning
Allow complete clotting
Centrifuge setup
Balance load per instrument instructions
Relative centrifugal force
Use specified ×g and time
Aliquot
Transfer portion and preserve identity
Bilirubin specimen
Protect from light
Transport
Match temperature, time, and method

Specimen Integrity

Clotted CBC
Unsuitable for cell counts
Underfilled citrate
May prolong clotting times
Hemolyzed potassium sample
Potassium may read falsely high
Potassium EDTA carryover
Potassium up, calcium down
Wrong tube
Verify test-specific acceptance criteria
Quantity not sufficient
Below required specimen volume
Add-on request
Check type, volume, and stability
Chain of custody
Record each transfer and receipt

Control Failure

Hold, fix, recheck, then retest

Hold patient testing and reportingConfirm acceptable QC before retesting

Internal vs External Controls

Internal

  • Built into kit or device
  • Checks specified procedural functions

External

  • Separate control material
  • Run per manufacturer instructions

Follow the device QC requirements

POCT Result Decisions

  1. Kit expired or stored improperly→Set kit aside(Replace per policy)
  2. Required control out of range→Stop patient testing and reporting(Troubleshoot and repeat controls)
  3. QC acceptable after correction→Repeat affected patient tests(Follow device and facility procedures)
  4. Result flagged critical→Follow critical-result notification policy(Document notification)
  5. Device displays invalid result→Troubleshoot per current instructions(Repeat as directed)

Waived Testing Setup

POCT
Testing near the patient
Waived classification
Applies to specific test systems
Waived method
Follow current manufacturer instructions
Approved specimen
Use the specified sample type
Reagents and strips
Check expiry and storage
Control schedule
Follow device instructions and policy
Urine dipstick
Read pads at specified times
Glucose meter
Check sample and strip compatibility
Rapid kit control
Verify control before interpreting result

Clean Catch vs Timed Urine

Clean catch

  • One midstream sample
  • Reduce contamination during collection

24-hour urine

  • Every void after starting discard
  • Include final timed void

Use the ordered collection method

Non-Blood Specimen Picker

  1. Clean-catch urine culture ordered→Use sterile midstream container(Avoid touching container interior)
  2. 24-hour urine ordered→Collect after discarding starting void(Include void at 24 hours)
  3. Sputum requested→Coach deep cough(Collect lower-airway secretions)
  4. Strep throat culture ordered→Use approved throat swab(Sample posterior pharynx and tonsils)

Urine Collections

Random urine
Single void without scheduled timing
Clean catch
Cleanse before collecting midstream
Timed urine start
Discard starting void
Timed urine finish
Include final void at deadline
Missed timed void
Contact lab for restart instructions
Urine preservative
Use test-specific supplied container

Swabs and Other Specimens

Stool sample
Keep separate from urine
Sputum sample
Deep cough from lower airways
Strep throat swab
Tonsils and posterior pharynx
Swab transport
Use assay-specified swab and medium
Cerebrospinal fluid (CSF)
Follow laboratory handling instructions
Federal workplace urine testing
Document custody and verify seals

Proficiency vs Competency

Proficiency testing

  • External challenge samples
  • Process using routine patient methods

Competency assessment

  • Evaluates individual staff performance
  • May include direct observation

Know what is being assessed

Exposure Response

  1. Needlestick or exposed skin→Wash with soap and water(Report immediately)
  2. Blood splashes into eyes→Flush with water promptly(Report immediately)
  3. Exposure has occurred→Seek prompt post-exposure evaluation(Follow facility exposure plan)
  4. Sharps bin at fill line→Replace using facility procedure(Keep sharps containers upright)

Sharps and Exposure

Standard Precautions
Apply with every patient
Hand hygiene
Before collection and after gloves
Routine blood draw
Wear gloves
Splash risk
Protect eyes, nose, and mouth
Safety-engineered needle
Engage safety per device instructions
Used needle
Discard directly into sharps container
Sharps container
Closable, puncture-resistant, leakproof sides/bottom
Exposure report
Promptly initiate post-exposure evaluation

Laboratory Quality and Privacy

Quality assurance
Monitors the whole testing process
Quality improvement
Track errors and verify fixes
Proficiency testing
Evaluate performance using external samples
Personnel competency
Assess performance of assigned duties
Preanalytic quality indicator
Track mislabeled specimens
Incident investigation
Document facts and corrective action
HIPAA Privacy Rule
Safeguard protected health information
Chemical safety data sheet
Check hazards and protective measures

Common Traps

Scaled score

400 on ASCP scaled score ≠ 40% of items correct

Patient identifiers

Name plus birth date ≠ Room plus bed number

Tube selection

Confirmed tube additive ≠ Matching stopper color alone

Winged set priming

Discard tube clears tubing air ≠ Citrate tube provides test specimen

Routine blood tube labeling

Label in patient’s presence ≠ Prelabel before seeing patient

Sample processing

Serum tube needs clotting ≠ CBC specimen needs anticoagulation

Waived test controls

Acceptable control supports testing ≠ Out-of-range control halts testing

Sputum quality

Deep-cough respiratory specimen ≠ Saliva from the mouth

Last Minute

  1. 1.Match two identifiers before collecting
  2. 2.Label tubes in patient’s presence
  3. 3.Draw venous cultures before citrate
  4. 4.If ordered, capillary gases precede EDTA
  5. 5.Fill citrate to designated mark
  6. 6.Invert additive tubes per manufacturer
  7. 7.Let serum clot before centrifuging
  8. 8.Check stability before accepting add-ons
  9. 9.Include final void at 24 hours
  10. 10.Hold POCT results when QC fails
  11. 11.Discard used needles into sharps containers
Same family resources

Explore More ASCP Certifications

Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.