Clean hands at the five WHO moments. Alcohol hand rub is preferred for routine use on clean-looking hands. Follow Maldives soap-and-water guidance for visible soil and suspected spore exposure.
Apply Standard Precautions to every patient. Use Contact, Droplet or Airborne precautions in addition according to the infection and facility policy.
Use the facility’s PPE sequence and keep an airborne respirator on until outside the room with the door closed.
Clean devices before terminal reprocessing and match the process to tissue contact and manufacturer instructions. Release sterilized loads only when monitoring requirements are met.
Hand hygiene at the point of care
The WHO Five Moments are:
- Before touching a patient.
- Before a clean or aseptic task.
- After body fluid exposure risk.
- After touching a patient.
- After touching patient surroundings.
Clean hands before putting on gloves as indicated and after removing them. Alcohol-based hand rub is preferred for routine care when hands are visibly clean. The WHO technique takes 20–30 seconds and ends with dry hands. Use soap and running water for visible soil or blood and after using the toilet. The WHO washing technique takes 40–60 seconds for the whole procedure. The Maldives IPC guideline prefers washing when exposure to spore-forming pathogens is strongly suspected or proven, including C. difficile outbreaks. It also identifies norovirus as a setting where hand rub alone may be insufficient. Use handwashing after caring for patients with norovirus during outbreaks and follow the facility procedure. Maldives IPC §§1.1.2–1.1.4 · WHO hand hygiene technique · CDC norovirus recommendations
Standard and Transmission-Based Precautions
Apply Standard Precautions to all patients. Choose gloves, gown, mask and eye protection according to anticipated contact or splash. Use aseptic injection and sharps safety, respiratory hygiene and cleaning of equipment. Use an unused sterile needle and syringe for each injection and dispose of them immediately after use. Add isolation measures when infection is suspected.
| Category | Placement and protection | Examples |
|---|---|---|
| Airborne | Use a negative-pressure airborne infection isolation room when available. Keep the door closed, and use a fit-tested particulate respirator under the facility respiratory protection program. If the room is unavailable, separate the patient promptly and contact infection control or arrange transfer. Mask the patient for essential transport when tolerated. | Suspected infectious pulmonary or laryngeal TB and measles. Varicella or disseminated zoster also requires Contact precautions. |
| Droplet | Place in a single room if possible or use approved cohorting. Wear a medical mask on entry under the facility policy. Use eye protection when exposure risk or pathogen guidance calls for it. Mask the patient for essential transport when tolerated. | Pertussis, seasonal influenza and meningococcal disease. For meningococcal disease the CDC lists Droplet precautions until 24 hours of effective therapy. |
| Contact | Use gown and gloves per room entry protocol. Use dedicated or disinfected equipment and clean high-touch surfaces. | Scabies, selected multidrug-resistant organisms or uncontained wound drainage. Use enteric measures for infectious diarrhea such as C. difficile. |
A positive-pressure, filtered Protective Environment is a separate intervention for selected patients, such as allogeneic stem cell transplant recipients. The team should consult IPC when a patient also needs isolation for an airborne infection. Room air changes depend on the applicable facility standard. In the CDC measles guidance, for example, airborne rooms have at least 6 air changes per hour in existing facilities or 12 for new construction and renovation. Use the applicable local engineering standard. CDC Isolation Appendix A · CDC measles IPC guidance · CDC isolation recommendations
Putting on and removing PPE
One commonly taught donning sequence is clean hands, gown, mask or respirator, eye protection, then gloves over the gown cuffs. Perform a user seal check each time you put on a tight-fitting respirator in addition to required fit testing.
For the separate-removal example below, take off gloves, remove eye protection by its strap or earpieces, then remove the gown by rolling the contaminated surface inward. Use the designated area for removal. When using Airborne precautions, leave the respirator in place until after exiting and closing the door. Remove it by its straps without touching the front. Clean hands if they become contaminated during removal and after all PPE is off. Some approved procedures remove the gown and gloves together. Follow the facility sequence for the specific precautions and equipment. CDC example PPE sequences
Spaulding classification and reprocessing
| Category | Patient contact | Minimum terminal process after thorough cleaning |
|---|---|---|
| Critical | Enters sterile tissue or the vascular system, such as a reusable surgical instrument. | Sterilization. Use a validated steam cycle when suitable or an approved compatible low-temperature process. |
| Semicritical | Touches mucous membranes or nonintact skin, such as many flexible endoscopes. | At least high-level disinfection. Sterilize if required by the device or facility instructions. Verify the entire validated process, including drying and storage. |
| Noncritical | Contacts intact skin, such as a blood pressure cuff. | Clean and use the appropriate low-level disinfectant. Use organism- and contamination-specific procedures for special situations. |
Handle disposable items according to facility policy. For reusable equipment, select the validated cycle for the device, packaging and sterilizer. Review physical cycle records for each load and check appropriate external and internal chemical indicators. Chemical indicator change shows exposure to specified process variables. Biological indicators test the process with resistant spores. Maldives IPC v2 prefers the first load of the day when sterilizers are used frequently and accepts at least weekly testing in units without multiple loads per day. It also requires biological indicators with each implant load and after specified changes or repairs. Follow quarantine, release and recall procedures when monitoring criteria fail. Maldives IPC reprocessing sections 1.5.15–1.5.16 · CDC sterilizing practices
A patient presents to an emergency department with fever, cough, conjunctivitis, generalized maculopapular rash spreading from the hairline downward, and small bluish-white Koplik spots on the buccal mucosa. Which transmission-based precautions must the nurse implement immediately?
Airborne precautions with a negative-pressure isolation room, a closed door and a fit-tested particulate respirator
Droplet precautions wearing only a surgical mask when standing within 1 meter of the patient
Protective positive-pressure isolation to shield the patient from ambient ward bacteria
Contact precautions using gown and gloves alone with an open room door for ventilation
A nurse finishes wound care in an Airborne and Contact isolation room. Using the separate-removal sequence taught in this section, put the PPE removal steps in order. Perform hand hygiene whenever hands become contaminated.
Arrange the items in the correct order
Remove the gown and roll its contaminated outside inward
Remove eye protection by its strap or earpieces in the designated doffing area
Exit the room, close the door, remove the respirator by its straps and clean hands
Peel off gloves without touching the contaminated outer surfaces with bare hands
Sections you finish are checked off in the contents.