Check the oxygen source and the device instructions. A simple face mask typically runs at 5–10 L/min. A reservoir mask needs enough flow to keep the bag from collapsing on inspiration.
The Maldives COPD guideline targets oxygen saturation of 88–92% when correcting hypoxemia during an acute exacerbation and recommends serial blood gases where available.
Preoxygenate adult patients who need artificial-airway suctioning, use sterile technique for open suction, and use shallow suctioning first. Limit suction to 15 seconds and generally avoid saline instillation.
Assess breathing and the pulse oximeter signal together. Conventional pulse oximetry cannot reliably exclude carbon monoxide poisoning.
Oxygen Delivery Devices, Airway Clearance and Pulse Oximetry
Assess the airway, work of breathing and oxygen saturation, then select an oxygen interface appropriate for the patient and the clinical target. Record the oxygen device and flow or fraction of inspired oxygen (FiO₂) with the oxygen saturation (SpO₂). A saturation of 94% while breathing room air has a different meaning from the same value after the patient has needed progressively more oxygen.
Choosing an oxygen delivery device
Conventional devices often provide part of the gas the patient inhales. The rest comes from room air, so the inspired oxygen concentration can change as the patient’s breathing pattern changes. An air-entrainment mask mixes a known proportion of oxygen and room air at the adapter. It supplies its intended mixture when total flow meets inspiratory demand and the air ports remain clear. Heated high-flow nasal oxygen uses a device that delivers a controlled, warmed, humidified gas mixture. It requires monitoring for response and signs of treatment failure.
| Device | When it is useful | What to check at the bedside |
|---|---|---|
| Conventional nasal cannula | A patient needs a small amount of supplemental oxygen and can breathe comfortably through the nose. | Check patency, tubing placement and skin contact points. The inspired oxygen fraction varies with breathing pattern. |
| Simple face mask | A patient needs more oxygen than a conventional cannula is providing. | A typical adult flow is 5–10 L/min. Follow the mask instructions and avoid flows below its minimum, which may allow exhaled gas to accumulate. |
| Reservoir mask | The patient needs high-concentration oxygen during an emergency. | Fill the bag before applying the mask. In emergency adult use, a non-rebreather reservoir mask is commonly started at 15 L/min. Check the source, connections, valves and fit. The reservoir should remain partly inflated during inspiration. |
| Venturi mask | Controlled oxygen is needed, such as in a patient at risk of hypercapnic respiratory failure. | Match the flow setting to the labelled adapter and keep the air-inlet ports clear. Reassess whether the patient’s demand exceeds the available gas flow. |
| Heated high-flow nasal oxygen | The team selects it for appropriate patients with acute hypoxemic respiratory failure. | Check the prescribed flow and FiO₂, humidification and the patient’s response. Escalate increasing work of breathing, drowsiness or persistent hypoxemia. |
If a reservoir bag repeatedly collapses, assess the patient and check the source, flow, mask and tubing promptly. Follow the emergency pathway if oxygenation remains inadequate. A reservoir mask cannot guarantee a fixed percentage because actual delivery depends on fit, flow and the patient’s demand. Thoracic Society of Australia and New Zealand acute oxygen statement · AARC acute-care oxygen guideline
Oxygen safety and acute COPD
Keep oxygen away from flames and smoking. Secure cylinders upright according to equipment and facility instructions and keep oil and grease away from fittings. For conventional oxygen flows above 4 L/min in adults, humidification may be considered for comfort. Heated high-flow systems have a separate humidification setup. WHO oxygen cylinder safety · AARC acute-care oxygen guideline
For a hypoxemic adult with an acute exacerbation of chronic obstructive pulmonary disease (COPD), section 8.2 of the Maldives COPD guideline targets 88–92% and recommends serial blood gases where available. Give needed oxygen promptly, titrate to the target and reassess. A Venturi mask is one way to start controlled oxygen. Excess oxygen can aggravate carbon dioxide retention, and a pulse oximeter does not show carbon dioxide or pH. Increasing somnolence, fatigue or persistent hypoxemia warrants urgent reassessment and escalation.
Interpreting the oximeter in context
A conventional pulse oximeter estimates saturation from light absorption. Inspect the signal and consider low perfusion, movement, skin pigmentation or nail products. If a reading is unexpected, assess the patient while checking the sensor and try another suitable site or device as needed. After possible carbon monoxide exposure, an apparently normal saturation is unreliable. Follow the emergency protocol and arrange laboratory co-oximetry on venous or arterial blood. FDA pulse oximetry guidance · CDC carbon monoxide guidance
Postoperative breathing and airway clearance
Review the patient’s ability to expand the lungs and clear secretions. Pain can limit the depth of a breath or inhibit an effective cough. Coordinate analgesia, early mobilization and coached deep breathing and coughing when appropriate. If incentive spirometry is included in the care plan, have the patient sit upright if tolerated and make a slow, sustained inspiration through the device. Pair it with the other parts of postoperative care. Incentive spirometry alone is not recommended as a routine prevention strategy. Chest physiotherapy or other airway-clearance techniques depend on secretion retention and the underlying condition. AARC incentive spirometry guideline · AARC airway clearance guideline
Airway adjuncts and suctioning
An oropharyngeal airway can help maintain a patent airway in an unresponsive patient without an effective gag reflex. A nasopharyngeal airway can be better tolerated when a gag reflex is present. In an adult with suspected basal skull fracture, prefer an oral airway when suitable and follow the advanced airway team’s plan. Neither adjunct alone protects against aspiration. ANZCOR adult advanced life support guidance
For an adult with an artificial airway, assess for retained secretions before suctioning. Visible secretions, altered breath sounds and a sawtooth ventilator waveform can support the decision. During open suctioning, use sterile technique. Choose a catheter and the lowest effective vacuum according to the tube and facility protocol. Preoxygenate an adult before suctioning. Advance the catheter gently without suction to the planned shallow depth, then apply suction as it is withdrawn and keep the suction event no longer than 15 seconds. Reserve deep suctioning for ineffective shallow suction and follow the applicable protocol. Generally avoid instilling saline into the airway. After a pass, restore oxygen delivery or ventilatory support as appropriate and reassess saturation, heart rate, breath sounds and whether another pass is needed. AARC artificial airway suctioning guideline
A patient with known COPD and previous carbon dioxide retention presents with an acute exacerbation. The patient is alert, has stable circulation and an SpO₂ of 86%, and is being assessed promptly. Which initial oxygen plan is appropriate while arranging blood gas assessment?
Withhold oxygen until the carbon dioxide result is available
Use a simple face mask at 3 L/min to reach a saturation of 99%
Start controlled oxygen using a Venturi mask and titrate to an SpO₂ of 88–92%, with prompt reassessment
Keep the oxygen flow fixed once treatment starts even if the saturation or alertness deteriorates
An adult with a tracheostomy has visible secretions. The nurse has confirmed that open suction is indicated. Put the following steps in order.
Arrange the items in the correct order
Apply suction during withdrawal, keeping the suction event to no more than 15 seconds
Advance the sterile catheter gently without suction to the planned shallow depth
Prepare sterile equipment, select the ordered or protocol-based vacuum setting, and preoxygenate
Restore oxygen delivery as appropriate and reassess before deciding whether another pass is needed