12.3 Tension Pneumothorax, Water-Seal Chest Drainage & Mechanical Ventilation Care
Key Takeaways
Suspect tension pneumothorax with unilateral loss of air entry and sudden severe respiratory or circulatory compromise. Activate emergency care and prepare for trained decompression without waiting for imaging in an unstable patient.
Keep a chest drain upright below chest level. Interpret bubbling, tidaling and drainage with the device, indication and patient findings. Report brisk bleeding or a sudden clinical change promptly.
For disconnection, assess the patient and restore closed drainage promptly under the device and facility protocol. For dislodgement from the chest, call for help, protect the site and prepare for reassessment.
For ventilator alarms, assess the patient immediately. High pressure can reflect obstruction or reduced compliance. Low pressure can reflect a leak or disconnection. Escalate new stridor and respiratory distress after extubation.
Pneumothorax, Water-Seal Chest Drainage and Ventilation
A pleural or airway problem can quickly interrupt oxygenation and circulation. Assess the patient immediately when symptoms or alarms change, call for help as needed and inspect the system while respiratory support is maintained.
Recognize the Pneumothorax Pattern
- Simple pneumothorax. Pleural air can partially or fully collapse a lung. Sudden pleuritic pain, breathlessness and reduced unilateral breath sounds are common clues. In a stable patient, arrange evaluation and imaging. Management depends on the cause, symptoms and physiology.
- Open pneumothorax. A penetrating chest-wall wound communicates with the pleural space. Activate the trauma pathway and monitor for worsening distress. In clinician-led trauma care, WSES/AAST describes a three-sided occlusive dressing as a temporary measure before definitive drainage and wound management. In first aid, AHA/Red Cross guidance instead permits leaving the wound exposed, a clean nonocclusive dressing or a vented chest seal. If breathing worsens after covering a wound, reassess promptly under the applicable protocol.
- Tension pneumothorax. Rising pleural pressure impairs ventilation and venous return and can cause obstructive shock. Suspect it with sudden severe distress or hypotension and reduced unilateral air entry, especially after trauma or during positive-pressure ventilation. Tracheal deviation is a late finding and may be absent. In an unstable patient, activate emergency care and prepare for immediate decompression by a trained clinician, followed by definitive drainage. Do not delay emergency treatment for imaging.
Recognize Hemothorax After Chest Trauma
Hemothorax is blood in the pleural space. It can impede lung expansion and cause blood-loss shock. Suspect it after chest trauma if reduced air entry on one side occurs with worsening breathing, pallor, tachycardia or poor perfusion. Air and blood may be present together. Activate the trauma response, reassess breathing and circulation and prepare for resuscitation and chest drainage as directed. If a drain is already in place, trend the bloody output and report rapid bleeding or clinical deterioration. An apparently low recorded output cannot exclude ongoing bleeding.
WSES–AAST thoracic trauma guideline
Manage the Drainage System
Keep the unit upright below chest level, connections secured, and tubing free of kinks and dependent loops. Record respiratory findings, drainage amount and appearance, and device observations at the prescribed intervals.
| Component | What to check |
|---|---|
| Collection chamber | Track output and appearance over time. A sudden rise, brisk fresh bleeding or circulatory deterioration requires urgent review. Use the notification limits prescribed for the indication and operation. Avoid routine stripping or milking. |
| Water seal | Maintain the fill level specified by the device, often the 2 cm mark. With an air leak from a pneumothorax, intermittent bubbling with exhalation or cough may be expected. New or increasing continuous bubbling warrants assessment for an ongoing pleural or system leak. Inspect the patient, insertion site and connections. A sudden stop in tidaling may reflect lung re-expansion, a kink, obstruction or displacement. Correlate with the examination and escalate unexplained changes. |
| Suction control | Use suction only when prescribed. Wet systems use a fluid level to set pressure and may require gentle bubbling in the suction chamber. Dry systems use a regulator and a device-specific indicator. Verify the set pressure and functioning using the manufacturer’s instructions. |
Drain Disconnection and Dislodgement
- Tubing disconnects from the unit. Assess breathing and oxygenation, call for assistance and restore a closed drainage system promptly, using the device instructions and the unit’s emergency procedure. Follow that procedure for immediate sterile reconnection or replacement. Clamping is not routine and can trap air. If the protocol calls for brief clamping solely during exchange, reopen the drain immediately after connection.
- Drain comes out of the chest. Get help immediately, protect the site with the dressing specified by the pleural protocol and reassess breathing and vital signs. Protocols distinguish pleural air from fluid when choosing the dressing. Do not reinsert the displaced tube. Prepare for clinician assessment and potential new drainage.
Ventilator Alarms
Assess oxygenation, chest rise, breath sounds, airway position and circulation before changing alarm limits. Call for urgent help if the patient deteriorates. If the ventilator is failing to ventilate the patient, provide manual ventilation with oxygen using the appropriate airway and equipment, according to training and emergency protocol, while the problem is corrected.
| Alarm | Likely causes | Immediate checks |
|---|---|---|
| High pressure | Kink, biting, secretions, bronchospasm or reduced lung or chest compliance from pulmonary edema, pneumothorax or other causes | Assess chest rise, breath sounds and tube depth. Trace tubing for obstruction and suction if indicated. Sudden one-sided loss of air entry with instability raises concern for tension pneumothorax. |
| Low pressure or low exhaled volume | Loose or disconnected circuit, cuff leak, displaced tube or accidental extubation | Check airway position and circuit integrity, reconnect if appropriate and measure cuff pressure with a manometer when indicated. If the tube is out, summon the airway team and support ventilation via an appropriate alternative airway. |
Prevent Ventilator-Associated Pneumonia and Recognize Airway Obstruction
Elevate the head of the bed 30–45 degrees if appropriate. Use hand hygiene and regular oral care with toothbrushing. SHEA recommends against routine chlorhexidine oral care solely for adult VAP prevention. Manage secretions safely, and use subglottic drainage in selected patients with an appropriate tube. Drain condensate away from the patient. Assess readiness for sedation reduction and a spontaneous breathing trial each day, when safe.
New inspiratory stridor with increased work of breathing after extubation suggests upper airway obstruction, which can result from laryngeal edema. Call the airway team, provide oxygen and assess for worsening respiratory failure. Be ready to assist with reintubation when obstruction persists or ventilation is failing.
An intubated adult develops a high-pressure ventilator alarm, agitation and a fall in SpO2 from 98% to 88%. What is the best immediate response?
Raise the high-pressure alarm limit and wait to see whether oxygenation improves.
Deflate the endotracheal cuff before examining the patient.
Disconnect all ventilatory support and wait for imaging.
Assess breathing, oxygenation and tube and circuit patency, call for help and support ventilation if inadequate.
An adult trauma patient has a closed water-seal chest drain. Which nursing actions support safe care? Select all that apply.
Select all that apply
Keep the drainage unit upright below the chest and keep the tubing free of kinks and dependent loops.
If the tubing disconnects, assess the patient, call for assistance and restore closed drainage using the device and unit protocol.
Clamp the chest drain routinely whenever transporting the patient.
Report brisk fresh bleeding or a sudden increase in bloody output and reassess the patient’s perfusion.
Strip the chest tube forcefully every hour to prevent blockage.
Sections you finish are checked off in the contents.