2.3 Vital Signs Assessment, Thermoregulation & Pain Management
Key Takeaways
Choose a temperature method appropriate to the patient and the device. Avoid rectal measurement in neutropenia. For suspected dengue, the Maldives guideline recommends paracetamol for fever and advises against aspirin and other NSAIDs.
Assess pulse rate and rhythm and record the work and pattern of breathing. Compare apical and radial pulse counts measured over the same period when checking for a pulse deficit.
Use an upper-arm cuff sized for the measured arm. The Maldives outpatient guideline checks orthostatic blood pressure after five minutes lying or sitting, then at one and three minutes standing.
Use patient self-report for pain when possible and a validated observational tool for patients who cannot self-report. Choose care and reassessment based on the pain cause, treatment and patient response.
Vital Signs, Temperature and Pain Assessment
Use vital signs and focused assessment together. A respiratory rate of 18 breaths/min does not tell you whether someone is struggling to breathe. Inspection uses direct observation. Watch the chest and abdomen for depth, symmetry, regularity, effort and retractions. Auscultation uses a stethoscope to assess breath sounds, which adds information to what you can see. Record how the measurement was obtained so the next clinician can compare values from similar conditions.
Temperature and fever assessment
Use a site and device appropriate for the patient’s age, consciousness and clinical condition. Oral, axillary and ear measurements are not interchangeable, and normal ranges vary by site. When following change over time, use the same suitable site and method where possible.
| Site | Practical consideration |
|---|---|
| Oral | A patient needs to be able to cooperate with the probe. Recent hot or cold drinks can distort a reading. Wait for the device’s recommended interval or select a suitable alternative. |
| Rectal | Avoid rectal measurement in a patient with neutropenia because mucosal injury can allow microorganisms into adjacent tissue. |
| Axillary | Place the probe against the skin and hold the arm against the body. An electronic axillary thermometer is recommended for infants younger than four weeks in NICE’s fever guideline. |
| Tympanic | Follow the thermometer instructions for the patient’s age and for positioning the probe. Technique affects the reading. |
IDSA fever and neutropenia guideline · NICE fever in under-5s guideline
Fever assessment includes symptom onset, fluid intake, urine output and warning signs. In the Maldives, inspect for bleeding, assess hydration and consider dengue in the clinical context. The Maldives dengue guideline advises paracetamol for fever and avoidance of aspirin and other nonsteroidal anti-inflammatory drugs (NSAIDs) in suspected dengue because of bleeding risk. Deterioration as the fever falls is a reason to reassess promptly.
Pulse and respiratory patterns
Assess pulse rate, rhythm and strength. The radial site is useful for routine adult assessment. With an irregular peripheral pulse, listen to the apical rate for a full minute. When comparing apical and radial pulses for a pulse deficit, count at both sites over the same minute. For example, an apical rate of 102 beats/min and a radial rate of 92 beats/min yield a deficit of 10 beats/min. In atrial fibrillation, some ventricular contractions may generate pulses too weak to palpate at the wrist.
Before giving a medicine such as digoxin that can slow heart rate or conduction, assess the rate and rhythm as ordered. Review prescribed hold parameters and clarify a new bradycardia or conduction abnormality with the treating team. Patient-specific orders determine the action. Digoxin prescribing information
Observe respiratory rate, regularity, depth, effort and pauses. Count for a full minute if irregular. These patterns can help you communicate what you see:
| Pattern | Features | Clinical association |
|---|---|---|
| Cheyne–Stokes | Cycles of increasing then decreasing depth with pauses | Can occur in heart failure or central neurologic disease |
| Kussmaul | Deep, sustained hyperventilation | Suggests compensation for substantial metabolic acidosis, such as diabetic ketoacidosis |
| Ataxic breathing | Markedly irregular breaths and pauses | Requires urgent assessment, especially with depressed consciousness |
Blood pressure and pulse oximetry
For routine outpatient blood pressure in adults, the Maldives Ministry of Health hypertension guideline advises a validated upper-arm device or calibrated auscultatory device. Let the patient rest comfortably for five minutes, then support the bare upper arm with the cuff at heart level. Measure mid-upper-arm circumference and select a cuff covering the manufacturer’s recommended range. The Maldives guideline specifies a bladder length of at least 80% and width of at least 40% of arm circumference. An undersized cuff tends to read high and an oversized cuff tends to read low. Those effects were measured in a randomized crossover trial. Protect a hemodialysis access arm and use a suitable alternative site according to the care plan.
When checking orthostatic blood pressure, begin after five minutes lying or sitting. Assist the patient to stand and repeat the blood pressure at one and three minutes. Record symptoms and help the patient sit or lie down if needed for safety. A fall of at least 20 mmHg systolic or 10 mmHg diastolic at either time meets the local guideline’s threshold. For example, a fall from 126/76 to 104/72 mmHg is 22 mmHg systolic and 4 mmHg diastolic, which meets the systolic criterion.
Pulse oximetry estimates arterial oxygen saturation. Low perfusion, movement, skin pigmentation and factors such as nail polish can affect the result. Inspect signal quality and the clinical picture together. A conventional two-wavelength pulse oximeter can give a falsely reassuring reading in carbon monoxide poisoning because it cannot account for carboxyhemoglobin. After an enclosed fire, symptoms and exposure history warrant prompt assessment even when the displayed saturation is normal. Laboratory co-oximetry can measure carboxyhemoglobin in venous or arterial blood. FDA pulse oximetry guidance · CDC carbon monoxide guidance
Pain assessment and reassessment
Ask about onset, location, quality, radiation, severity, timing, triggers and effects on breathing, sleep or movement. Use the patient’s report when they can communicate. An awake adult may use a 0–10 numeric scale. The Wong–Baker FACES scale is a self-report tool for people aged three and older who can use it. FLACC (Face, Legs, Activity, Cry, Consolability) is a behavioral tool originally validated for postoperative pain in children aged two months to seven years. In a critically ill adult unable to self-report, the Critical-Care Pain Observation Tool (CPOT) can help when behavior can be observed. A change in vital signs cues further assessment.
Agree on a functional goal, such as enough comfort to breathe deeply or transfer to a chair. Combine prescribed medicines and suitable measures such as supported positioning or relaxation according to the cause and setting. Reassess at the interval appropriate to the intervention and whenever the patient’s condition changes. Record relief, function and adverse effects. WHO guidance for cancer pain in adults and adolescents selects initial medication according to severity and clinical assessment. Acute postoperative care has its own analgesia plan. Wong–Baker FACES Foundation · Original FLACC validation · SCCM adult intensive care guidance · WHO cancer pain guidance
A nurse prepares to measure vital signs in four hospitalized adult patients. For which patient is taking a rectal temperature contraindicated?
An alert patient who drank warm tea 5 minutes ago
An oncology patient with severe chemotherapy-induced neutropenia
A patient receiving supplemental oxygen via simple face mask
A postoperative patient sleeping comfortably on a nasal cannula
After rescue from an enclosed house fire, a firefighter has a headache and answers questions slowly. A conventional pulse oximeter displays 99%. In another room, a nurse uses an oversized blood-pressure cuff on a thin adult. What measurement errors should the nurse anticipate?
Pulse oximetry is falsely low; the oversized cuff yields a falsely high blood pressure
Pulse oximetry is accurate for oxygenation; the oversized cuff yields an accurate blood pressure
Pulse oximetry is falsely low; the oversized cuff yields a falsely low blood pressure
The oximeter can give a falsely reassuring result in carbon monoxide exposure, and the oversized cuff tends to read low
Sections you finish are checked off in the contents.