4.2 Intraoral Techniques, Paralleling vs. Bisecting, SLOB Rule & Panoramic Errors
Key Takeaways
For a paralleling projection, align the receptor as nearly parallel to the tooth as possible and direct the central ray perpendicular to both.
When using the bisecting-angle technique, a vertical angle that is too steep can shorten the image. Aim through proximal contacts to reduce overlap.
An unattenuated beam from an ideal point source has one-quarter the intensity at twice the distance. Clinical exposure settings follow equipment protocols.
With two useful parallax views, a target that shifts in the direction of the tube relative to a reference lies lingual to that reference.
Use the panoramic unit’s positioning aids and review the diagnostic region for distortion or artifacts before deciding on another exposure.
Match the projection to the clinical question
A periapical image should capture the tooth, apex and relevant periapical bone. A bitewing shows the crowns and the adjacent alveolar crests of both arches. Select images in response to the history and findings and check previous images first.
| Technique | Geometry | Practical check |
|---|---|---|
| Paralleling periapical | Receptor approximately parallel to the tooth long axis and central ray perpendicular to both. A longer source-to-object distance reduces magnification and geometric blur when the receptor is farther from the tooth. | Use an alignment holder. Palatal shape or a rigid sensor can make parallel positioning difficult. Verify that the image includes the target tooth and its apex. |
| Bisecting-angle periapical | When the receptor and tooth form an angle, direct the central ray perpendicular to the imaginary bisector of that angle. | A beam angled too steeply can give foreshortened roots. A beam that is too shallow can elongate them. |
| Bitewing | Direct the horizontal beam through the interproximal contacts. Use a compatible holder and the vertical angulation appropriate for the technique. | Overlapping contacts can obscure proximal caries. A vertical bitewing may show more of the bone in a patient with periodontal loss. If the apex is needed, take a suitable periapical projection. |
For example, when roots appear foreshortened on a maxillary bisecting-angle periapical and the receptor placement was appropriate, reassess the vertical angle. For overlapping bitewing contacts, evaluate the horizontal beam alignment instead. Correct the error if the image cannot answer the clinical question and another exposure is justified.
Use the actual focal spot distance for the calculation
The inverse-square relation for a point source assumes fixed output and geometry other than distance, without a change in attenuation or scatter. At fixed tube current and exposure duration, the ratio at two distances is:
For example, with an unattenuated beam a measured air kerma of 4.5 mGy at 20 cm corresponds to about 2.0 mGy at 30 cm because . If the true focal spot-to-detector distance doubles, the air kerma at fixed exposure time is one quarter as large under the same assumptions. In that model, four times the exposure time at fixed tube current restores the original detector air kerma. A position-indicating device’s stated length alone does not establish the focal spot-to-detector distance. Use the approved technique chart for actual patient exposures.
Locate a superimposed object with parallax
Compare two images made from different tube positions when localization can affect management. Identify the same target and reference structure on both images. SLOB means same lingual, opposite buccal. The comparison is relative to the chosen reference, so describe the target as lingual or palatal, or buccal or labial, relative to that structure. Keep the views sufficiently comparable to identify a genuine relative shift.
For example, to assess an unerupted maxillary canine relative to the adjacent lateral incisor, review the first image and a justified image obtained with a horizontal tube shift. If a mesial shift of the tube makes the canine crown appear more mesial relative to the incisor root, the canine crown lies palatal to that root. Movement in the opposite direction would support a labial location. If two adequately acquired views leave uncertainty that affects treatment, consider whether further imaging is justified.
Read panoramic positioning clues
A rotating panoramic unit produces the clearest images of structures lying within its curved image layer, also called the focal trough. Follow the unit’s instructions for head alignment, posture and bite position. If a radiopaque object remains in place, its shadow may reproduce on the opposite side higher and magnified as a ghost image. Review the relevant region for artifacts before diagnosing disease or ordering a repeat.
| Appearance | Likely positioning or preparation issue |
|---|---|
| Flattened or reversed occlusal curve; hard palate can overlap maxillary root apices | Chin tipped too high |
| Exaggerated smile curve with anterior distortion | Chin tipped too low |
| Narrow, blurred anterior teeth | Patient too far forward relative to the image layer |
| Wide, blurred anterior teeth | Patient too far back relative to the image layer |
| Dense shadow in the anterior midline | Slumped posture can place the cervical spine in the beam. A high apron can also cause a sharply defined radiopaque wedge coming from the lower edge of the image. Check the setup. |
| Broad dark band across maxillary apices | Tongue was not against the palate, leaving a palatoglossal air space |
If the unit uses a bite block, position the incisors in the intended notch and ask the patient to hold still and keep the tongue against the palate. Identify removable objects that could obscure the image. Where facility policy calls for shielding, ensure it sits clear of the useful beam.
Sources
- DHA Dental Radiology guideline CG-11 issue 2, section 7 on image justification
- Rinn intraoral radiography positioning manual
- Original study on projection differences and alveolar crest measurements
- Original study on rigid receptor placement and tooth alignment
- IAEA diagnostic radiology physics handbook
- Clark’s original radiographic localization paper
- Carestream panoramic radiography technique and positioning illustrations
- University of Toronto Faculty of Dentistry panoramic technique
- Original clinical study on panoramic positioning errors
A maxillary canine periapical obtained with the bisecting-angle technique shows a shortened root. The receptor is positioned as intended, and the vertical beam angle is visibly steeper than the perpendicular to the bisecting plane. If the nondiagnostic image must be repeated, what should the clinician change?
Increase positive vertical angulation by 15 degrees
Decrease positive vertical angulation so the beam is perpendicular to the bisector
Shift the tube head 20 degrees distally without altering vertical angulation
Decrease exposure time while keeping the cone at 8 inches
A panoramic image shows a sharply demarcated, opaque triangular wedge projecting upward from the lower edge over the anterior mandible. The patient was upright, the occlusal curve is normal and the facility used a protective apron. Which preparation problem would explain this artifact?
The patient failed to press their tongue against the hard palate
The patient's chin was tipped too high above the Frankfort plane
The patient was positioned too far posterior to the bite-block groove
A protective apron or collar was placed too high on the patient's neck
To localize an unerupted maxillary right canine (FDI 13) relative to the lateral incisor root (FDI 12), a dentist compares two justified periapical images. After a mesial tube shift, the canine crown projects farther mesial relative to the lateral incisor root. Where does the crown lie?
Palatal to the lateral incisor root
Labial to the lateral incisor root
Directly inferior in the alveolar crest
Inside the maxillary sinus floor
In a point-source test with a fixed tube current, fixed kVp and no attenuating object, an exposure of 0.08 s gives the desired detector air kerma at a focal spot-to-detector distance of 20 cm. What exposure time gives the same air kerma at 40 cm?
0.04 s
0.16 s
0.32 s
0.64 s
Sections you finish are checked off in the contents.