1.4 DHA Infection Control in Dentistry (CG-10): Sterilization, PPE, DUWLs & Sharps Safety

Key Takeaways

  • DHA CG-10 issue 2 separates dirty decontamination, clean preparation and sterilization, and sterile storage. Clean devices by a method specified in the manufacturer’s instructions.

  • Clean and heat-sterilize heat-tolerant intraoral handpieces and other heat-stable critical and semicritical equipment between patients.

  • After a positive biological indicator, check cycle records and chemical indicators, correct and retest as directed, and follow CG-10’s recall procedure if the cause remains unknown and the repeat test is positive.

  • CG-10 Appendix 3 lists a heterotrophic plate count below 200 CFU/mL, checked monthly, and no Legionella detected on quarterly testing. Surgical procedures require sterile irrigant.

  • After a needlestick, stop work, wash with soap and water and obtain urgent exposure assessment to determine whether post-exposure prophylaxis is indicated.

Last updated: November 2026

Reprocessing begins with the device and its intended use

The Dubai Health Authority’s Clinical Guidelines for Infection Control in Dentistry (CG-10, issue 2, effective 1 March 2026) cover cleaning, sterilization, personal protection and exposure management in dental clinics. Spaulding classification groups instruments by what they contact. Check a reusable device’s instructions for compatible cleaning, packaging and processing. Discard devices labelled single-use through the appropriate waste stream.

CategoryExamplesReprocessing decision
CriticalAn extraction forceps or bur that penetrates tissue or boneClean, then sterilize before reuse.
SemicriticalMouth mirrors, reusable impression trays and routine intraoral handpiecesClean and heat-sterilize heat-tolerant items. Follow validated instructions for heat-sensitive devices.
NoncriticalBlood pressure cuff or light handle contacting intact skinClean and disinfect between patients with the indicated low- or intermediate-level product. Manage clinical contact surfaces with appropriate barriers or disinfection under CG-10.

A high-speed or low-speed handpiece can retain patient material inside the instrument. Wiping its outer surface does not reprocess the internal components. Follow the manufacturer’s device-specific steps for cleaning, lubrication where instructed, and heat sterilization between patients. DHA advises against putting handpieces into an ultrasonic cleaner.

Move items from dirty to clean areas

  1. Decontaminate. Carry soiled instruments in a closed, puncture-resistant, leakproof container. Heavy-duty puncture- and chemical-resistant utility gloves protect hands during cleaning. Use the manufacturer’s method. DHA prefers mechanical cleaning when suitable, while some devices require manual cleaning.
  2. Prepare and package. Open hinges or disassemble devices as directed so surfaces can be cleaned. Inspect, dry and package items in appropriate wraps or pouches. Use the required indicators and label packs for traceability.
  3. Sterilize and inspect. Select a cycle compatible with the contents and follow the sterilizer’s loading instructions. Check cycle records and package indicators. Inspect cooled packages for a seal breach, moisture or damage before release.
  4. Store safely. Store sterile packages protected from damage and moisture. A wet or torn package is compromised. Follow the facility’s storage policy and rotate supplies so older stock is used first.

Interpret sterilizer monitoring

MonitorWhat to check
PhysicalReview time, temperature and pressure at the end of each cycle against the selected cycle parameters.
ChemicalUse an external indicator to distinguish a processed pack from an unprocessed one. An internal indicator reports exposure to the conditions it is designed to monitor inside the pack.
BiologicalThe spore test assesses whether a defined biological challenge survives the process. CG-10 recommends routine steam testing weekly, preferably daily, and qualification testing after a new installation, relocation or major repair.

A positive biological indicator requires action even when the cycle printout looks normal. Follow the recall procedure in CG-10 §6.5.9. Review physical and chemical results, return affected items for reprocessing and retest the equipment with biological, physical and chemical indicators after correcting identified procedural problems. If an operator error is identified and the retest is negative, correct the error and reprocess the load. If the cause is unidentified and the repeat result remains positive, quarantine the load and recall and reprocess items back to the last negative biological result.

Water, protective equipment and sharps

Dental-unit waterlines can harbour biofilm. Follow the water-treatment system instructions, verify performance with testing and flush the lines as directed by DHA. CG-10 specifies 20–30 seconds after each patient and 2–3 minutes at the start of the day. The Dubai Municipality schedule reproduced in CG-10 Appendix 3 lists a heterotrophic plate count below 200 colony-forming units per millilitre (CFU/mL) monthly and no Legionella detected quarterly. A result of 260 CFU/mL calls for prompt review of treatment, retreatment and repeat testing. Use sterile saline or sterile water through a sterile delivery system for procedures such as dentoalveolar surgery, endodontic surgery and implant placement.

Choose personal protective equipment (PPE) for the tasks and exposure risk, including suitable gloves and eye and face protection for splashes. Change patient-care gloves between patients. Remove protective gowns before eating, breaks or leaving the practice. Put needles and blades immediately into a puncture-resistant sharps container close to the point of use. When recapping is necessary, use a one-handed scoop or a device designed to hold the cap. Follow the local waste segregation scheme, including the designated containers for sharps and amalgam waste.

A sharps injury calls for immediate first aid and evaluation. Stop work and let a puncture bleed freely without squeezing. Wash with soap and water. Flush an eye splash with water or saline. Report and document the exposure and obtain urgent physician assessment. Source and exposed-worker testing and the indication for post-exposure prophylaxis (PEP) depend on the incident. The occupational health team should evaluate exposure promptly to avoid delaying any indicated treatment.

Sources

Loading diagram...
Instrument flow from decontamination to sterile storage
Test Your Knowledge

An assistant cleans used extraction forceps in the decontamination area while wearing thin examination gloves, then wipes a reusable high-speed handpiece before the next patient. The manufacturer specifies heat sterilization for the handpiece. What changes are required?

A

Change to latex examination gloves and soak the handpiece in a liquid germicide.

B

Use chlorhexidine to wipe the handpiece and keep the examination gloves for cleaning.

C

Run a biological indicator test before wiping the handpiece and use double examination gloves.

D

Wear puncture- and chemical-resistant utility gloves to decontaminate the forceps, and clean and heat-sterilize the handpiece as directed.

Test Your Knowledge

A steam sterilizer gives a positive biological indicator. The clinic checks the cycle records, finds no cause and repeats testing under its CG-10 procedure. The repeat biological indicator is positive. What should the clinic do with the affected instruments?

A

Release routine instruments because the cycle printouts were normal.

B

Quarantine the implicated load and recall and reprocess items processed back to the last negative biological indicator.

C

Release any package with a changed external chemical indicator.

D

Reprocess only the instrument sets containing surgical burs.

Test Your Knowledge

A dentist performs a surgical extraction that requires bone removal. Which irrigation source and delivery method are appropriate?

A

Water from the chair’s routine line after flushing for 30 seconds.

B

Distilled water from a routine dental-unit reservoir that passed its monthly microbial test.

C

Sterile saline or sterile water delivered through a sterile irrigation system.

D

Treated water from the standard nonsterile air-water syringe.

Test Your Knowledge

A dentist punctures a finger on a used local anesthetic needle. The patient’s bloodborne infection status is unknown. What is the best immediate response?

A

Stop work, let the puncture bleed freely without squeezing, wash with soap and water, report the injury and obtain urgent medical assessment for indicated prophylaxis.

B

Squeeze the wound hard, apply bleach and wait for the patient’s test results before reporting.

C

Use alcohol hand rub only and continue treating patients.

D

Cover the wound without washing and schedule a routine titer check next month.

Sections you finish are checked off in the contents.