11.2 Surgical Placement Protocol, Esthetic Zone Dimensions & Prosthetic Options
Key Takeaways
Plan implant position from the restoration, root and implant clearance, facial contour and soft-tissue goals.
DHA CG-06 calls for at least 3 mm between adjacent implants. Verify the actual edge-to-edge distance and root clearance.
Assess facial bone and mucosal thickness with the planned restoration. Excessively facial or coronal placement can compromise esthetics and cleanability.
Use sterile irrigant and follow the implant system’s surgical instructions. Select loading from achieved stability, tissue conditions and occlusal risk.
Screw retention can aid retrieval and avoid submucosal luting cement. When cement is used, make the margin accessible for cleanup.
Plan Implant Position From the Restoration
Start with the intended crown or prosthesis, esthetic expectations and a cleanable emergence profile. Use the examination, diagnostic setup and appropriately justified imaging to assess bone, adjacent roots, mucosal contour and the proposed access channel. A guide can transfer the plan to the mouth. Assess its fit and allow for placement error. Consider different timing, augmentation or another restoration if the ideal position cannot be achieved. DHA implant dentistry CG-06 issue 2 · ITI consensus on single anterior implants
Three-Dimensional Planning
| Dimension | What to check |
|---|---|
| Mesiodistal | Check edge-to-edge spacing between implants and actual clearance to adjacent roots on the planned trajectory. DHA CG-06 specifies at least 3 mm between adjacent implants. |
| Buccolingual | Preserve facial bone and allow space for the planned emergence contour. For an anterior screw-retained crown, DHA CG-06 describes the center under the future cingulum. Confirm that the trajectory works for the site and restoration. |
| Apicocoronal | Set platform depth relative to the planned facial mucosal margin, implant design and space needed for a cleanable emergence. Evaluate the neighboring teeth and soft tissues. |
If two parallel implants measure 3.6 mm and 4.8 mm across at the assessment level, their radii are 1.8 mm and 2.4 mm. A 3 mm gap requires mm between centers at that level. Recheck the actual geometry for tapered or angled implants. A 1.5 mm implant-to-root distance is a common planning reference. Check root trajectory and remaining support rather than assuming that one number guarantees a result across designs. DHA CG-06 Part 2 §§12–13 · Original inter-implant spacing study · Original implant-tooth proximity study
Papillary fill depends on the type of neighboring support and distance from the contact to the bone crest. In Tarnow’s natural-tooth study, a crest-to-contact distance of 5 mm or less was associated with near-universal fill in that sample. A separate adjacent-implant study found a mean soft-tissue height of about 3.4 mm above the inter-implant crest. Treat these as population observations and evaluate the patient’s tissues and restoration. Natural-tooth papilla study · Adjacent-implant papilla height study
At a visible central incisor site, a thin facial plate and an excessively facial trajectory increase the risk of a facial contour deficit and mucosal recession. Excessively coronal positioning can compromise emergence and concealment of components. Assess the facial bone and tissue phenotype before choosing immediate or staged placement or contour augmentation. Clinical assessment of immediate placement and recession · Prospective thin and thick facial plate cohort · ITI single-tooth consensus
Irrigation, Stability and Loading
Use sharp instruments, the manufacturer’s recommended sequence and adequate sterile coolant. DHA CG-10 specifies sterile irrigants such as sterile water or saline for surgical use. Ordinary dental-unit water is unsuitable for this purpose. A classic rabbit experiment found reduced bone formation after heating to 47 °C for one minute. Apply that evidence as a reason to control heat, using the implant system’s protocol. DHA infection-control CG-10 issue 2 · Original animal threshold study
Placement timing refers to when surgery occurs after extraction. Loading timing concerns when a prosthesis is connected and put into function. ITI terminology distinguishes immediate loading within one week with functional contact from immediate restoration within one week out of occlusion. It places early loading between one week and two months and conventional loading after two months. Primary stability can be assessed using insertion torque or resonance frequency analysis. The measures describe different properties. Immediate treatment needs suitable anatomy, stability in the planned position and an occlusal plan that protects healing. If those conditions are lacking, use the appropriate alternative protocol. ITI timing definitions · ITI 2023 selection guidance
At a single anterior site, an implant can be placed at the extraction visit and still be restored later. If primary stability cannot support an immediate provisional, defer restoration of the implant and discuss a temporary option that avoids pressure on the surgical site. This is immediate placement with later restoration. To classify the loading protocol, document the date the implant is restored and whether that restoration has functional occlusal contact.
Restoration Retention and Maintenance
Screw retention can improve retrievability and avoids submucosal crown luting cement. Check access position, component limits and space. If cement retention is selected, design the margin to be accessible for excess cement removal. Deeper margins make cleanup less reliable. Use clinical checks and indicated imaging, recognizing that radiographs can miss residual cement. Persistent bleeding or suppuration warrants examination for local contributors, probing changes and bone loss relative to baseline. Prospective residual cement study · Prospective abutment margin study · EFP peri-implant disease guideline
Two parallel implants each measure 4 mm in diameter at the level being planned. DHA CG-06 specifies at least 3 mm between their edges. What center-to-center distance gives that gap at this level?
5 mm
7 mm
8 mm
11 mm
For a single implant at #11 with a high smile line and a thin facial plate, which positioning choice most increases the risk of a facial contour or mucosal deficit?
A position that leaves facial bone support and suits the intended restoration
A position that allows an accessible and cleanable emergence contour
A planned change in timing because the facial contour needs augmentation
An excessively facial and coronal position next to the thin plate
Which irrigation choice is consistent with DHA CG-10 during a surgical osteotomy?
Use a sterile irrigant such as sterile water or sterile saline with an appropriate sterile delivery system
Use ordinary dental-unit water because the drill is sterile
Omit irrigation in dense bone to improve stability
Use a routine oral rinse as the surgical coolant
An implant crown has a deep cement margin and the patient develops localized bleeding and suppuration. A radiopaque fragment is seen near the margin. Which feature of screw retention can reduce this particular risk in future treatment?
It eliminates the need to monitor inflammation around the implant
It removes the clinical need to clean the emergence profile
It avoids submucosal crown luting cement and can facilitate retrieval
It guarantees that the supporting bone remains unchanged
Sections you finish are checked off in the contents.