Under South Dakota's adoption of the UPC, what is the minimum size drain pipe permitted for a water closet?

A
B
C
D
to track
2026 Statistics

Key Facts: SD Plumber Exam

70%

Passing Score

Plumbing Commission

80

Questions

3 hours

~$185

Exam Fee

PSI

UPC

Code

Plumbing Commission

South Dakota's journeyman plumber exam is administered by PSI on behalf of the Plumbing Commission. It has approximately 80 questions with a 3 hours time limit and requires 70% to pass. The exam fee is ~$185. South Dakota uses the UPC as its plumbing code.

Sample SD Plumber Practice Questions

Try these sample questions to test your SD Plumber exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1Under South Dakota's adoption of the UPC, what is the minimum size drain pipe permitted for a water closet?
A.2 inches
B.3 inches
C.4 inches
D.1-1/2 inches
Explanation: Per the UPC as adopted by South Dakota, the minimum drain pipe size for a water closet is 3 inches.
2What is the minimum slope for a 4-inch horizontal drainage pipe in South Dakota?
A.1/4 inch per foot
B.1/8 inch per foot
C.1/2 inch per foot
D.1/16 inch per foot
Explanation: Pipes 3 inches and larger require 1/8 inch per foot slope. Pipes under 3 inches require 1/4 inch per foot.
3What is the DFU value for a 1.6 GPF water closet in South Dakota?
A.3 DFU
B.4 DFU
C.2 DFU
D.6 DFU
Explanation: Per UPC tables, a 1.6 GPF WC is 4 DFU. UPC assigns 4 DFU, differing from IPC (3).
4What backflow preventer is required for high-hazard cross-connections in South Dakota?
A.RPZ backflow preventer
B.Atmospheric vacuum breaker
C.Dual check valve
D.Hose bibb vacuum breaker
Explanation: An RPZ is required for high-hazard cross-connections with two check valves and a differential relief valve.
5What is the minimum trap seal depth in South Dakota?
A.1 inch
B.2 inches
C.3 inches
D.4 inches
Explanation: Minimum 2 inches, maximum 4 inches. The seal prevents sewer gas entry.
6What is the minimum vent pipe size in South Dakota?
A.1 inch
B.1-1/4 inches
C.1-1/2 inches
D.2 inches
Explanation: Minimum vent size is 1-1/4 inches. Must be at least half the drain size served.
7What is the maximum static water pressure in South Dakota?
A.60 psi
B.80 psi
C.100 psi
D.120 psi
Explanation: Maximum 80 psi. PRV required when supply exceeds this limit.
8When is a cleanout required on horizontal drainage in South Dakota?
A.At direction changes over 45 degrees
B.At direction changes over 90 degrees
C.Only at building drain
D.Every 25 feet
Explanation: Cleanouts required at direction changes over 45 degrees.
9What device must be on every water heater in South Dakota?
A.T&P relief valve
B.Check valve
C.Gate valve
D.Expansion tank only
Explanation: T&P relief valve opens at 210°F or 150 psi to prevent catastrophic failure.
10What is the max shower/bathtub delivery temperature in South Dakota?
A.110°F
B.120°F
C.130°F
D.140°F
Explanation: 120°F max at showers and bathtubs. Mixing valve required.

About the SD Plumber Exam

South Dakota-specific journeyman plumber licensing exam based on the UPC covering drainage, water supply, venting, gas piping, and fixtures

Questions

80 scored questions

Time Limit

3 hours

Passing Score

70%

Exam Fee

~$185 (Plumbing Commission / PSI)

SD Plumber Exam Content Outline

25%

Drainage Systems & Pipe Sizing

Drain sizing, fixture units (DFU), slope requirements, cleanouts, building drain and sewer sizing per UPC

20%

Water Supply & Distribution

Pipe sizing, backflow prevention, pressure regulation, cross-connection control, and water service requirements

20%

Venting Systems

Vent sizing, wet venting, air admittance valves, vent termination, circuit venting, and combination waste and vent

15%

Fixtures & Appliances

Fixture installation, clearances, water heaters, accessible fixtures, and commercial fixture requirements

10%

Gas Piping

Gas pipe sizing, appliance venting, pressure testing, BTU calculations, CSST bonding, and combustion air

10%

Code Administration & Special Systems

Permits, inspections, plan review, South Dakota state amendments, medical gas, grease interceptors, and storm drainage

How to Pass the SD Plumber Exam

What You Need to Know

  • Passing score: 70%
  • Exam length: 80 questions
  • Time limit: 3 hours
  • Exam fee: ~$185

Keys to Passing

  • Complete 500+ practice questions
  • Score 80%+ consistently before scheduling
  • Focus on highest-weighted sections
  • Use our AI tutor for tough concepts

SD Plumber Study Tips from Top Performers

1Master DFU values and drain pipe sizing — heavily tested on every exam
2Memorize minimum pipe sizes, slopes, and fixture clearances from code tables
3Practice backflow prevention device selection for different hazard levels
4Study gas piping sizing, pressure testing, and combustion air requirements
5Learn to navigate the UPC index quickly for efficient code lookup
6Review water heater installation including T&P valve requirements
7Practice with timed exams to develop time management skills
8Focus on venting methods — wet venting, circuit venting, and AAV rules

Frequently Asked Questions

What plumbing code does South Dakota use?

South Dakota uses the UPC for its plumbing licensing exam. Candidates should study the current adopted edition with any state-specific amendments.

Who administers the South Dakota plumber exam?

The exam is administered by PSI on behalf of the Plumbing Commission. Register through PSI after your application is approved.

What is the passing score?

South Dakota requires 70% to pass the journeyman plumber exam. The exam has 80 questions with a 3 hours time limit.

Is the exam open book?

Most PSI-administered plumbing exams allow a bound copy of the adopted plumbing code. No loose pages, handwritten notes, or electronic devices are permitted. Check current exam policies before your test date.