1 / 100
Question 1
Score: 0/0

Under South Carolina's adoption of the IPC, what is the minimum size drain pipe permitted for a water closet?

A
B
C
D
to track
2026 Statistics

Key Facts: SC Plumber Exam

70%

Passing Score

LLR Contractors Licensing Board

80

Questions

3 hours

~$190

Exam Fee

PSI

IPC

Code

LLR Contractors Licensing Board

South Carolina's journeyman plumber exam is administered by PSI on behalf of the LLR Contractors Licensing Board. It has approximately 80 questions with a 3 hours time limit and requires 70% to pass. The exam fee is ~$190. South Carolina uses the IPC as its plumbing code.

Sample SC Plumber Practice Questions

Try these sample questions to test your SC Plumber exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1Under South Carolina's adoption of the IPC, what is the minimum size drain pipe permitted for a water closet?
A.2 inches
B.3 inches
C.4 inches
D.1-1/2 inches
Explanation: Per the IPC as adopted by South Carolina, the minimum drain pipe size for a water closet is 3 inches.
2What is the minimum slope for a 4-inch horizontal drainage pipe in South Carolina?
A.1/4 inch per foot
B.1/8 inch per foot
C.1/2 inch per foot
D.1/16 inch per foot
Explanation: Pipes 3 inches and larger require 1/8 inch per foot slope. Pipes under 3 inches require 1/4 inch per foot.
3What is the DFU value for a 1.6 GPF water closet in South Carolina?
A.4 DFU
B.3 DFU
C.2 DFU
D.6 DFU
Explanation: Per IPC tables, a 1.6 GPF WC is 3 DFU. IPC assigns 3 DFU, differing from UPC (4).
4What backflow preventer is required for high-hazard cross-connections in South Carolina?
A.RPZ backflow preventer
B.Atmospheric vacuum breaker
C.Dual check valve
D.Hose bibb vacuum breaker
Explanation: An RPZ is required for high-hazard cross-connections with two check valves and a differential relief valve.
5What is the minimum trap seal depth in South Carolina?
A.1 inch
B.2 inches
C.3 inches
D.4 inches
Explanation: Minimum 2 inches, maximum 4 inches. The seal prevents sewer gas entry.
6What is the minimum vent pipe size in South Carolina?
A.1 inch
B.1-1/4 inches
C.1-1/2 inches
D.2 inches
Explanation: Minimum vent size is 1-1/4 inches. Must be at least half the drain size served.
7What is the maximum static water pressure in South Carolina?
A.60 psi
B.80 psi
C.100 psi
D.120 psi
Explanation: Maximum 80 psi. PRV required when supply exceeds this limit.
8When is a cleanout required on horizontal drainage in South Carolina?
A.At direction changes over 45 degrees
B.At direction changes over 90 degrees
C.Only at building drain
D.Every 25 feet
Explanation: Cleanouts required at direction changes over 45 degrees.
9What device must be on every water heater in South Carolina?
A.T&P relief valve
B.Check valve
C.Gate valve
D.Expansion tank only
Explanation: T&P relief valve opens at 210°F or 150 psi to prevent catastrophic failure.
10What is the max shower/bathtub delivery temperature in South Carolina?
A.110°F
B.120°F
C.130°F
D.140°F
Explanation: 120°F max at showers and bathtubs. Mixing valve required.

About the SC Plumber Exam

South Carolina-specific journeyman plumber licensing exam based on the IPC covering drainage, water supply, venting, gas piping, and fixtures

Questions

80 scored questions

Time Limit

3 hours

Passing Score

70%

Exam Fee

~$190 (LLR Contractors Licensing Board / PSI)

SC Plumber Exam Content Outline

25%

Drainage Systems & Pipe Sizing

Drain sizing, fixture units (DFU), slope requirements, cleanouts, building drain and sewer sizing per IPC

20%

Water Supply & Distribution

Pipe sizing, backflow prevention, pressure regulation, cross-connection control, and water service requirements

20%

Venting Systems

Vent sizing, wet venting, air admittance valves, vent termination, circuit venting, and combination waste and vent

15%

Fixtures & Appliances

Fixture installation, clearances, water heaters, accessible fixtures, and commercial fixture requirements

10%

Gas Piping

Gas pipe sizing, appliance venting, pressure testing, BTU calculations, CSST bonding, and combustion air

10%

Code Administration & Special Systems

Permits, inspections, plan review, South Carolina state amendments, medical gas, grease interceptors, and storm drainage

How to Pass the SC Plumber Exam

What You Need to Know

  • Passing score: 70%
  • Exam length: 80 questions
  • Time limit: 3 hours
  • Exam fee: ~$190

Keys to Passing

  • Complete 500+ practice questions
  • Score 80%+ consistently before scheduling
  • Focus on highest-weighted sections
  • Use our AI tutor for tough concepts

SC Plumber Study Tips from Top Performers

1Master DFU values and drain pipe sizing — heavily tested on every exam
2Memorize minimum pipe sizes, slopes, and fixture clearances from code tables
3Practice backflow prevention device selection for different hazard levels
4Study gas piping sizing, pressure testing, and combustion air requirements
5Learn to navigate the IPC index quickly for efficient code lookup
6Review water heater installation including T&P valve requirements
7Practice with timed exams to develop time management skills
8Focus on venting methods — wet venting, circuit venting, and AAV rules

Frequently Asked Questions

What plumbing code does South Carolina use?

South Carolina uses the IPC for its plumbing licensing exam. Candidates should study the current adopted edition with any state-specific amendments.

Who administers the South Carolina plumber exam?

The exam is administered by PSI on behalf of the LLR Contractors Licensing Board. Register through PSI after your application is approved.

What is the passing score?

South Carolina requires 70% to pass the journeyman plumber exam. The exam has 80 questions with a 3 hours time limit.

Is the exam open book?