Key Facts: OR Plumber Exam

70%

Passing Score

Building Codes Division

100

Questions

3 hours

~$100+$265

Exam Fee

PSI

OSPC (based on UPC)

Code

Building Codes Division

Oregon's journeyman plumber exam is administered by PSI on behalf of the Building Codes Division. It has approximately 100 questions with a 3 hours time limit and requires 70% to pass. The exam fee is ~$100+$265. Oregon uses the OSPC (Oregon Specialty Plumbing Code, based on UPC) as its plumbing code.

Sample OR Plumber Practice Questions

Try these sample questions to review concepts for the OR Plumber exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 298+ question experience with AI tutoring.

1Oregon uses the Oregon Specialty Plumbing Code (OSPC), which is based on which national plumbing code?
A.Uniform Plumbing Code (UPC)
B.International Plumbing Code (IPC)
C.National Standard Plumbing Code (NSPC)
D.NFPA 5000 Plumbing Chapter
Explanation: Oregon's Specialty Plumbing Code (OSPC) is based on the Uniform Plumbing Code (UPC) published by IAPMO, with Oregon-specific amendments adopted by the Building Codes Division. Plumbers must know both the UPC foundation and Oregon's specific modifications to pass the journeyman exam.
2Under Oregon's OSPC, what is the minimum size drain pipe for a water closet?
A.3 inches
B.4 inches
C.2 inches
D.1-1/2 inches
Explanation: Per the OSPC (based on UPC), the minimum drain size for a water closet is 3 inches. This matches the UPC requirement and ensures adequate flow capacity for toilet discharge. The building drain receiving water closet discharge must also be at least 3 inches.
3According to Oregon's Building Codes Division, who administers the journeyman plumber licensing exam?
A.PSI (testing vendor for Oregon BCD)
B.Pearson VUE
C.Prometric
D.Oregon Building Codes Division directly
Explanation: Oregon's journeyman plumber exam is administered by PSI on behalf of the Building Codes Division (BCD). Candidates must apply through BCD and receive authorization before scheduling with PSI. The exam tests knowledge of the OSPC and Oregon plumbing regulations.
4Under Oregon's OSPC, what is the minimum slope for a 4-inch horizontal drainage pipe?
A.1/8 inch per foot
B.1/4 inch per foot
C.1/2 inch per foot
D.1/16 inch per foot
Explanation: Per the UPC-based OSPC, horizontal drainage pipes 3 inches and larger require a minimum slope of 1/8 inch per foot (approximately 1% grade). Pipes smaller than 3 inches require 1/4 inch per foot. The slope ensures self-scouring velocity to carry solids through the system.
5Per Oregon's OSPC, what is the fixture unit value for a residential water closet (1.6 GPF or less)?
A.3 DFU
B.4 DFU
C.2 DFU
D.6 DFU
Explanation: Under the UPC (and Oregon's OSPC), a residential water closet rated at 1.6 GPF or less is assigned 4 DFU. Note that this differs from the IPC, which assigns 3 DFU. Oregon exam candidates must know the UPC-based values, not the IPC values.
6Under Oregon's OSPC, what is the minimum trap seal depth?
A.2 inches
B.3 inches
C.1 inch
D.4 inches
Explanation: The OSPC (UPC-based) requires a minimum trap seal of 2 inches and a maximum of 4 inches. The trap seal prevents sewer gases from entering the building. Trap seals can be lost through evaporation, siphonage, or back-pressure if the system is not properly vented.
7Per Oregon's OSPC, what is the maximum distance a 1-1/2 inch P-trap can be from its vent?
A.5 feet (60 inches) developed length
B.6 feet
C.8 feet
D.3-1/2 feet
Explanation: Per UPC Table 1002.2, the maximum distance from a 1-1/2 inch trap to its vent is 6 feet developed length. This distance ensures the vent can adequately protect the trap seal from siphonage. Exceeding this distance requires either a larger trap arm or relocation of the vent.
8Under Oregon's OSPC, what type of backflow preventer is required for a high-hazard cross-connection?
A.Reduced pressure principle (RP) backflow preventer
B.Atmospheric vacuum breaker
C.Dual check valve
D.Pressure vacuum breaker
Explanation: Oregon's OSPC requires a reduced pressure principle (RP) backflow preventer for high-hazard (health hazard) cross-connections. The RP device protects against both backsiphonage and backpressure conditions. It contains two independently acting check valves with a pressure differential relief valve between them.
9Per Oregon's OSPC, what is the minimum vent pipe size?
A.1-1/4 inches
B.1 inch
C.1-1/2 inches
D.2 inches
Explanation: The OSPC (UPC-based) sets the minimum vent pipe size at 1-1/4 inches. Additionally, the vent must be at least one-half the size of the drain it serves. Individual vents for water closets must be at least 2 inches in diameter.
10In Oregon, what is the maximum static water pressure permitted in a building distribution system per the OSPC?
A.80 psi
B.60 psi
C.100 psi
D.120 psi
Explanation: The OSPC limits maximum static water pressure to 80 psi. When incoming pressure exceeds 80 psi, an approved pressure-reducing valve must be installed. This protects fixtures, appliances, and piping from damage caused by excessive pressure.

About the OR Plumber Exam

Oregon-specific journeyman plumber licensing exam based on the OSPC (Oregon Specialty Plumbing Code, based on UPC) covering drainage, water supply, venting, gas piping, and fixtures

Exam sponsor: Building Codes Division / PSI. The requirements and fees below concern the certification or admission exam, separate from our free practice resources.

Questions

100 questions

Time Limit

3 hours

Passing Score

70%

Exam / Certification Fees

~$100+$265

Exam sponsor website

Reported exam pass rate: ~50%. This describes exam candidates, not OpenExamPrep users or results from using our resources. Exam sponsor website

Fees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.

Our practice resources: topics covered

We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.

25%

Drainage Systems & Pipe Sizing

Drain sizing, fixture units (DFU), slope requirements, cleanouts, building drain and sewer sizing per OSPC (based on UPC)

20%

Water Supply & Distribution

Pipe sizing, backflow prevention, pressure regulation, cross-connection control, and water service requirements

20%

Venting Systems

Vent sizing, wet venting, air admittance valves, vent termination, circuit venting, and combination waste and vent

15%

Fixtures & Appliances

Fixture installation, clearances, water heaters, accessible fixtures, and commercial fixture requirements

10%

Gas Piping

Gas pipe sizing, appliance venting, pressure testing, BTU calculations, CSST bonding, and combustion air

10%

Code Administration & Special Systems

Permits, inspections, plan review, Oregon state amendments, medical gas, grease interceptors, and storm drainage

Preparing for the OR Plumber Exam

What You Need to Know

  • Passing score: 70%
  • Exam length: 100 questions
  • Time limit: 3 hours
  • Exam / certification fees: ~$100+$265 Official sources

Using Our Practice Resources

  • Work through all 298 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

OR Plumber: Suggested Study Strategy

1Master DFU values and drain pipe sizing — heavily tested on every exam
2Memorize minimum pipe sizes, slopes, and fixture clearances from code tables
3Practice backflow prevention device selection for different hazard levels
4Study gas piping sizing, pressure testing, and combustion air requirements
5Learn to navigate the OSPC (based on UPC) index quickly for efficient code lookup
6Review water heater installation including T&P valve requirements
7Practice with timed exams to develop time management skills
8Focus on venting methods — wet venting, circuit venting, and AAV rules

Frequently Asked Questions

What plumbing code does Oregon use?

Oregon uses the OSPC (Oregon Specialty Plumbing Code, based on UPC) for its plumbing licensing exam. Candidates should study the current adopted edition with any state-specific amendments.

Who administers the Oregon plumber exam?

The exam is administered by PSI on behalf of the Building Codes Division. Register through PSI after your application is approved.

What is the passing score?

Oregon requires 70% to pass the journeyman plumber exam. The exam has 100 questions with a 3 hours time limit.

Is the exam open book?

Most PSI-administered plumbing exams allow a bound copy of the adopted plumbing code. No loose pages, handwritten notes, or electronic devices are permitted. Check current exam policies before your test date.